메뉴 건너뛰기




Volumn 250, Issue , 2010, Pages 34-38

The characterisation of a genipin-gelatin gel dosimeter

Author keywords

[No Author keywords available]

Indexed keywords

BLENDING; IRRADIATION; SULFURIC ACID;

EID: 78650536915     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/250/1/012008     Document Type: Conference Paper
Times cited : (7)

References (8)
  • 2
    • 0035001585 scopus 로고    scopus 로고
    • Experimental determination of the diffusion coefficient in two dimensions in ferrous sulphate gels using the finite element method
    • Baldock C, Harris P J, Piercy A R and Healy B 2001. Experimental determination of the diffusion coefficient in two dimensions in ferrous sulphate gels using the finite element method. Australas. Phys. Eng. Sci. Med. 24, 19-30.
    • (2001) Australas. Phys. Eng. Sci. Med. , vol.24 , pp. 19-30
    • Baldock, C.1    Harris, P.J.2    Piercy, A.R.3    Healy, B.4
  • 3
    • 41849142594 scopus 로고    scopus 로고
    • Sensitivity and stability of the Fricke-gelatin-xylenol orange gel dosimeter
    • Davies J B and Baldock C, 2008. Sensitivity and stability of the Fricke-gelatin-xylenol orange gel dosimeter. Rad. Phys. Chem. 77, 690-696.
    • (2008) Rad. Phys. Chem. , vol.77 , pp. 690-696
    • Davies, J.B.1    Baldock, C.2
  • 4
    • 0348170745 scopus 로고    scopus 로고
    • Preparation of networks of gelatin and genipin as degradable biomaterials
    • Yao C, Liu B, Chang C, Hsu S, Chen Y. 2004. Preparation of networks of gelatin and genipin as degradable biomaterials. Mat. Chem. Phys. 83, 204-208.
    • (2004) Mat. Chem. Phys. , vol.83 , pp. 204-208
    • Yao, C.1    Liu, B.2    Chang, C.3    Hsu, S.4    Chen, Y.5
  • 5
    • 78650581424 scopus 로고    scopus 로고
    • Zero diffusion radiochromic genipin-gelatin dosimeter
    • Jordan K. 2008. Zero diffusion radiochromic genipin-gelatin dosimeter. Med. Phys. 35, 3413.
    • (2008) Med. Phys. , vol.35 , pp. 3413
    • Jordan, K.1
  • 6
    • 67650681147 scopus 로고    scopus 로고
    • Optical CT scanning of cross-linked radiochromic gel without cylinder wall
    • Jordan K. 2009. Optical CT scanning of cross-linked radiochromic gel without cylinder wall. J. Phys.: Conf. Ser. 164, 012029.
    • (2009) J. Phys.: Conf. Ser. , vol.164 , pp. 012029
    • Jordan, K.1
  • 7
    • 34248208783 scopus 로고    scopus 로고
    • Initial investigation of a novel light-scattering gel phantom for evaluation of optical CT scanners for radiotherapy gel dosimetry
    • Bosi S, Naseri P, Puran A, Davies J and Baldock C. 2007. Initial investigation of a novel light-scattering gel phantom for evaluation of optical CT scanners for radiotherapy gel dosimetry. Phys. Med. Biol. 52, 2893-2903.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 2893-2903
    • Bosi, S.1    Naseri, P.2    Puran, A.3    Davies, J.4    Baldock, C.5
  • 8
    • 78650554177 scopus 로고    scopus 로고
    • Zero diffusion radiochromic genipin-gelatin dosimeter for three-dimensional radiation dosimetry
    • June
    • Jordan K. June 2008. Zero diffusion radiochromic genipin-gelatin dosimeter for three-dimensional radiation dosimetry. Conference Proceedings COMP annual meeting.
    • (2008) Conference Proceedings COMP Annual Meeting
    • Jordan, K.1