-
1
-
-
33947388425
-
IMRT verification using a radiochromic/optical-CT dosimetry system
-
Oldham M, Guo P, Gluckman G and Adamovics J 2006 IMRT verification using a radiochromic/optical-CT dosimetry system J. Phys. 56 221-4
-
(2006)
J. Phys.
, vol.56
, pp. 221-224
-
-
Oldham, M.1
Guo, P.2
Gluckman, G.3
Adamovics, J.4
-
2
-
-
67649619540
-
Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using presage/optical-CT
-
Sakhalkar H, Sterling D, Adamovics J, Ibbott G and Oldham M 2009 Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using presage/optical-CT Med. Phys. 36 3371-7
-
(2009)
Med. Phys.
, vol.36
, pp. 3371-3377
-
-
Sakhalkar, H.1
Sterling, D.2
Adamovics, J.3
Ibbott, G.4
Oldham, M.5
-
3
-
-
58149113034
-
A comprehensive evaluation of the PRESAGE/optical- CT 3D dosimetry system
-
Sakhalkar H S, Adamovics J, Ibbott G and Oldham M 2009 A comprehensive evaluation of the PRESAGE/optical- CT 3D dosimetry system Med. Phys. 36 71-82
-
(2009)
Med. Phys.
, vol.36
, pp. 71-82
-
-
Sakhalkar, H.S.1
Adamovics, J.2
Ibbott, G.3
Oldham, M.4
-
4
-
-
33749391614
-
A practical three-dimensional dosimetry system for radiation therapy
-
DOI 10.1118/1.2349686
-
Guo P, Adamovics J and Oldham M 2006 A practical three-dimensional dosimetry system for radiation therapy Med. Phys. 33 3962-72 (Pubitemid 44505118)
-
(2006)
Medical Physics
, vol.33
, Issue.10
, pp. 3962-3972
-
-
Guo, P.1
Adamovics, J.2
Oldham, M.3
-
5
-
-
76849096681
-
Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/ optical-CT 3D dosimetry system
-
Clift C, Thomas A , Adamovics J, Chang Z, Das I and Oldham M 2010 Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/ optical-CT 3D dosimetry system Phys. Med. Biol. 55 1279-93
-
(2010)
Phys. Med. Biol.
, vol.55
, pp. 1279-1293
-
-
Clift, C.1
Thomas, A.2
Adamovics, J.3
Chang, Z.4
Das, I.5
Oldham, M.6
-
6
-
-
78650529770
-
-
Proton-Beam Therapy International Commission on Radiation Units and Measurements Bethesda Imprint Bethesda, MD 7 No 2
-
ICRU Report 78 2007 Prescribing, Recording, and Reporting. Proton-Beam Therapy International Commission on Radiation Units and Measurements Bethesda Imprint Bethesda, MD 7 No 2
-
ICRU Report 78 2007 Prescribing, Recording, and Reporting
-
-
-
7
-
-
77951775866
-
Gafchromic EBT film dosimetry in proton beams
-
Zhao L and Das I 2010 Gafchromic EBT film dosimetry in proton beams Phys. Med. Biol. 55 N291-301
-
(2010)
Phys. Med. Biol.
, vol.55
-
-
Zhao, L.1
Das, I.2
-
9
-
-
65449186980
-
The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams
-
Reft C 2009 The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams Med. Phys. 36 1690-99
-
(2009)
Med. Phys.
, vol.36
, pp. 1690-1699
-
-
Reft, C.1
-
10
-
-
77952393562
-
Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy
-
Zeidan O A, Sriprisan S I,Lopatiuk-Tirpak O,Kupelian P A, Meeks S L, His W C, Li Z, Palta J R and Maryanski M J 2010 Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy Med. Phys. 37 2145-52
-
(2010)
Med. Phys.
, vol.37
, pp. 2145-2152
-
-
Zeidan, O.A.1
Sriprisan, S.I.2
Lopatiuk-Tirpak, O.3
Kupelian, P.A.4
Meeks, S.L.5
His, W.C.6
Li, Z.7
Palta, J.R.8
Maryanski, M.J.9
-
11
-
-
33947410398
-
True-3D scans using PRESAGETM and Optical-CT: A case study in proton therapy
-
Doran S, Al-Nowais S, Krstaji N, Adamovics J, Kacperek A and Brunt J 2006 True-3D scans using PRESAGETM and Optical-CT: A case study in proton therapy J. Phys.: Conf. Ser. 56 231
-
(2006)
J. Phys.: Conf. Ser.
, vol.56
, pp. 231
-
-
Doran, S.1
Al-Nowais, S.2
Krstaji, N.3
Adamovics, J.4
Kacperek, A.5
Brunt, J.6
-
12
-
-
0038715468
-
Use of BANG polymer gel for dose measurements in a 68 MeV proton beam
-
DOI 10.1118/1.1575557
-
Heufelder J, Stiefel S, Pfaender M, Ludemann L, Grebe G and Heese J 2003 Use of BANG polymer gel for dose measurements in a 68 MeV proton beam Med. Phys. 30 1235-40 (Pubitemid 36735990)
-
(2003)
Medical Physics
, vol.30
, Issue.6
, pp. 1235-1240
-
-
Heufelder, J.1
Stiefel, S.2
Pfaender, M.3
Ludemann, L.4
Grebe, G.5
Heese, J.6
|