메뉴 건너뛰기




Volumn 34, Issue 6, 2010, Pages 830-835

Whole-brain perfusion measurement using 320-detector row computed tomography in patients with cerebrovascular steno-occlusive disease: Comparison with 15O-positron emission tomography

Author keywords

320Ydetector row CT; PET; whole brain CT perfusion

Indexed keywords

COMPUTERIZED TOMOGRAPHY; POSITRON EMISSION TOMOGRAPHY; REGRESSION ANALYSIS;

EID: 78650453647     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/RCT.0b013e3181ebd16a     Document Type: Article
Times cited : (12)

References (29)
  • 1
    • 0021331235 scopus 로고
    • Evaluation of cerebral perfusion reserve in patients with carotid-artery occlusion
    • Gibbs JM, Wise RJ, Leenders KL, et al. Evaluation of cerebral perfusion reserve in patients with carotid-artery occlusion. Lancet. 1984;1:310-314.
    • (1984) Lancet. , vol.1 , pp. 310-314
    • Gibbs, J.M.1    Wise, R.J.2    Leenders, K.L.3
  • 2
    • 0021742185 scopus 로고
    • Physiological responses to focal cerebral ischemia in humans
    • Powers WJ, Grubb RL Jr, Raichle ME. Physiological responses to focal cerebral ischemia in humans. Ann Neurol. 1984;16:546-552.
    • (1984) Ann Neurol. , vol.16 , pp. 546-552
    • Powers, W.J.1    Grubb Jr., R.L.2    Raichle, M.E.3
  • 3
    • 0035155768 scopus 로고    scopus 로고
    • Perfusion mapping using computed tomography allows accurate prediction of cerebral infarction in experimental brain ischemia
    • Nabavi DG, Cenic A, Henderson S, et al. Perfusion mapping using computed tomography allows accurate prediction of cerebral infarction in experimental brain ischemia. Stroke. 2001;32:175-183.
    • (2001) Stroke. , vol.32 , pp. 175-183
    • Nabavi, D.G.1    Cenic, A.2    Henderson, S.3
  • 4
    • 64649092845 scopus 로고    scopus 로고
    • Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke. Part 1. Theoretic basis
    • Konstas AA, Goldmakher GV, Lee TY, et al. Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke. Part 1. Theoretic basis. AJNR Am J Neuroradiol. 2009;30:662-668.
    • (2009) AJNR Am J Neuroradiol. , vol.30 , pp. 662-668
    • Konstas, A.A.1    Goldmakher, G.V.2    Lee, T.Y.3
  • 5
    • 77958523306 scopus 로고    scopus 로고
    • Evaluations of CT perfusion in the setting of cerebral ischemia: Patterns and pitfalls
    • [Epub ahead of print]
    • LuiYW, Tang ER, Allmendinger AM, et al. Evaluations of CT perfusion in the setting of cerebral ischemia: Patterns and pitfalls. AJNR Am J Neuroradiol. 2010. [Epub ahead of print].
    • (2010) AJNR Am J Neuroradiol.
    • Lui, Y.W.1    Tang, E.R.2    Allmendinger, A.M.3
  • 6
    • 58249101218 scopus 로고    scopus 로고
    • Tracer delay-insensitive algorithm can improve reliability of CT perfusion imaging for cerebrovascular steno-occlusive disease: Comparison with quantitative single-photon emission CT
    • Sasaki M, Kudo K, Ogasawara K, et al. Tracer delay-insensitive algorithm can improve reliability of CT perfusion imaging for cerebrovascular steno-occlusive disease: Comparison with quantitative single-photon emission CT. AJNR Am J Neuroradiol. 2009;30:188-193.
    • (2009) AJNR Am J Neuroradiol. , vol.30 , pp. 188-193
    • Sasaki, M.1    Kudo, K.2    Ogasawara, K.3
  • 7
    • 0035037004 scopus 로고    scopus 로고
    • Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: A validation study
    • Wintermark M, Thiran J, Maeder P, et al. Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: A validation study. AJNR Am J Neuroradiol. 2001;22:905-914.
    • (2001) AJNR Am J Neuroradiol. , vol.22 , pp. 905-914
    • Wintermark, M.1    Thiran, J.2    Maeder, P.3
  • 8
    • 33748472373 scopus 로고    scopus 로고
    • Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease
    • Bisdas S, Nemitz O, Berding G, et al. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease. Eur Radiol. 2006;16:2220-2228.
    • (2006) Eur Radiol. , vol.16 , pp. 2220-2228
    • Bisdas, S.1    Nemitz, O.2    Berding, G.3
  • 9
    • 51449123139 scopus 로고    scopus 로고
    • Perfusion CT compared to H2 15O/O15O PET in patients with chronic cervical carotid artery occlusion
    • Kamath A, Smith WS, Powers WJ, et al. Perfusion CT compared to H2 15O/O15O PET in patients with chronic cervical carotid artery occlusion. Neuroradiology. 2008;50:745-751.
    • (2008) Neuroradiology. , vol.50 , pp. 745-751
    • Kamath, A.1    Smith, W.S.2    Powers, W.J.3
  • 10
    • 33644663805 scopus 로고    scopus 로고
    • Volumetric perfusion CT using prototype 256Ydetector row CT scanner: Preliminary study with healthy porcine model
    • Mori S, Obata T, Nakajima N, et al. Volumetric perfusion CT using prototype 256Ydetector row CT scanner: Preliminary study with healthy porcine model. AJNR Am J Neuroradiol. 2005;26:2536-2541.
    • (2005) AJNR Am J Neuroradiol. , vol.26 , pp. 2536-2541
    • Mori, S.1    Obata, T.2    Nakajima, N.3
  • 11
    • 70349247851 scopus 로고    scopus 로고
    • Radiation dose from multidetector row CT imaging for acute stroke
    • Mnyusiwalla A, Aviv RI, Symons SP, et al. Radiation dose from multidetector row CT imaging for acute stroke. Neuroradiology. 2009;51:635-640.
    • (2009) Neuroradiology. , vol.51 , pp. 635-640
    • Mnyusiwalla, A.1    Aviv, R.I.2    Symons, S.P.3
  • 12
    • 58049207881 scopus 로고    scopus 로고
    • 4-D imaging in cerebrovascular disorders by using 320-slice CT: Feasibility and preliminary clinical experience
    • Klingebiel R, Siebert E, Diekmann S, et al. 4-D imaging in cerebrovascular disorders by using 320-slice CT: Feasibility and preliminary clinical experience. Acad Radiol. 2009;16:123-129.
    • (2009) Acad Radiol. , vol.16 , pp. 123-129
    • Klingebiel, R.1    Siebert, E.2    Diekmann, S.3
  • 13
    • 58149359754 scopus 로고    scopus 로고
    • Whole-brain perfusion CT performed with a prototype 256Ydetector row CT system: Initial experience
    • Murayama K, Katada K, Nakane M, et al. Whole-brain perfusion CT performed with a prototype 256Ydetector row CT system: Initial experience. Radiology. 2009;250:202-211.
    • (2009) Radiology. , vol.250 , pp. 202-211
    • Murayama, K.1    Katada, K.2    Nakane, M.3
  • 14
    • 0037344519 scopus 로고    scopus 로고
    • Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: Comparison with H2(15)O positron emission tomography
    • Kudo K, Terae S, Katoh C, et al. Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: Comparison with H2(15)O positron emission tomography. AJNR Am J Neuroradiol. 2003;24:419-426.
    • (2003) AJNR Am J Neuroradiol. , vol.24 , pp. 419-426
    • Kudo, K.1    Terae, S.2    Katoh, C.3
  • 15
    • 0037587219 scopus 로고    scopus 로고
    • Tracer arrival timing-insensitive technique for estimating flow in MR perfusionYweighted imaging using singular value decomposition with a block-circulant deconvolution matrix
    • Wu O, Ostergaard L, Weisskoff RM, et al. Tracer arrival timing-insensitive technique for estimating flow in MR perfusionYweighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med. 2003;50:164-174.
    • (2003) Magn Reson Med. , vol.50 , pp. 164-174
    • Wu, O.1    Ostergaard, L.2    Weisskoff, R.M.3
  • 16
    • 1542346897 scopus 로고    scopus 로고
    • Removing the effect of SVD algorithmic artifacts present in quantitative MR perfusion studies
    • Smith MR, Lu H, Trochet S, et al. Removing the effect of SVD algorithmic artifacts present in quantitative MR perfusion studies. Magn Reson Med. 2004;51:631-634.
    • (2004) Magn Reson Med. , vol.51 , pp. 631-634
    • Smith, M.R.1    Lu, H.2    Trochet, S.3
  • 17
    • 77049181625 scopus 로고
    • On the theory of the indicator-dilution method for measurement of blood flow and volume
    • Meier P, Zierler KL. On the theory of the indicator-dilution method for measurement of blood flow and volume. J Appl Physiol. 1954;6:731-744.
    • (1954) J Appl Physiol. , vol.6 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 18
    • 0034128435 scopus 로고    scopus 로고
    • A standardized method for measuring intracranial arterial stenosis
    • Samuels OB, Joseph GJ, Lynn MJ, et al. A standardized method for measuring intracranial arterial stenosis. AJNR Am J Neuroradiol. 2000;21:643-646.
    • (2000) AJNR Am J Neuroradiol. , vol.21 , pp. 643-646
    • Samuels, O.B.1    Joseph, G.J.2    Lynn, M.J.3
  • 19
    • 0032511955 scopus 로고    scopus 로고
    • Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis
    • North American Symptomatic Carotid Endarterectomy Trial Collaborators
    • Barnett HJ, Taylor DW, Eliasziw M, et al. Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators. N Engl J Med. 1998;339:1415-1425.
    • (1998) N Engl J Med. , vol.339 , pp. 1415-1425
    • Barnett, H.J.1    Taylor, D.W.2    Eliasziw, M.3
  • 20
    • 0028926692 scopus 로고
    • Regional cerebral blood flow, blood volume, oxygen extraction fraction, and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method
    • Hatazawa J, Fujita H, Kanno I, et al. Regional cerebral blood flow, blood volume, oxygen extraction fraction, and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method. Ann Nucl Med. 1995;9:15-21.
    • (1995) Ann Nucl Med. , vol.9 , pp. 15-21
    • Hatazawa, J.1    Fujita, H.2    Kanno, I.3
  • 21
    • 37649020473 scopus 로고    scopus 로고
    • Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: Validation by comparison with 2-dimensional PET
    • Ibaraki M, Miura S, Shimosegawa E, et al. Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: Validation by comparison with 2-dimensional PET. J Nucl Med. 2008;49:50-59.
    • (2008) J Nucl Med. , vol.49 , pp. 50-59
    • Ibaraki, M.1    Miura, S.2    Shimosegawa, E.3
  • 22
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet. , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 23
    • 0031964096 scopus 로고    scopus 로고
    • Cerebral hematocrit decreases with hemodynamic compromise in carotid artery occlusion: A PET study
    • Yamauchi H, Fukuyama H, Nagahama Y, et al. Cerebral hematocrit decreases with hemodynamic compromise in carotid artery occlusion: A PET study. Stroke. 1998;29:98-103.
    • (1998) Stroke. , vol.29 , pp. 98-103
    • Yamauchi, H.1    Fukuyama, H.2    Nagahama, Y.3
  • 24
    • 0016284544 scopus 로고
    • Evidence of the limitations of water as a freely diffusible tracer in brain of the rhesus monkey
    • Eichling JO, Raichle ME, Grubb RL Jr, et al. Evidence of the limitations of water as a freely diffusible tracer in brain of the rhesus monkey. Circ Res. 1974;35:358-364.
    • (1974) Circ Res. , vol.35 , pp. 358-364
    • Eichling, J.O.1    Raichle, M.E.2    Grubb Jr., R.L.3
  • 25
    • 0023430879 scopus 로고
    • Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using 15O water and 11C butanol
    • Herscovitch P, Raichle ME, Kilbourn MR, et al. Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using 15O water and 11C butanol. J Cereb Blood Flow Metab. 1987;7:527-542.
    • (1987) J Cereb Blood Flow Metab. , vol.7 , pp. 527-542
    • Herscovitch, P.1    Raichle, M.E.2    Kilbourn, M.R.3
  • 26
    • 14644402442 scopus 로고    scopus 로고
    • Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI
    • Ibaraki M, Shimosegawa E, Toyoshima H, et al. Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI. J Cereb Blood Flow Metab. 2005;25:378-390.
    • (2005) J Cereb Blood Flow Metab. , vol.25 , pp. 378-390
    • Ibaraki, M.1    Shimosegawa, E.2    Toyoshima, H.3
  • 27
    • 42949094595 scopus 로고    scopus 로고
    • Effect of vascular stenosis on perfusion-weighted imaging: Differences between calculation algorithms
    • Matsushima S, Kubota T, Yamada K, et al. Effect of vascular stenosis on perfusion-weighted imaging: Differences between calculation algorithms. J Magn Reson Imaging. 2008;27:1103-1108.
    • (2008) J Magn Reson Imaging. , vol.27 , pp. 1103-1108
    • Matsushima, S.1    Kubota, T.2    Yamada, K.3
  • 28
    • 0032936419 scopus 로고    scopus 로고
    • Correlation of regional cerebral blood flow from perfusion MRI and SPECT in normal subjects
    • Ernst T, Chang L, Itti L, et al. Correlation of regional cerebral blood flow from perfusion MRI and SPECT in normal subjects. Magn Reson Imaging. 1999;17:349-354.
    • (1999) Magn Reson Imaging. , vol.17 , pp. 349-354
    • Ernst, T.1    Chang, L.2    Itti, L.3
  • 29
    • 33645744261 scopus 로고    scopus 로고
    • Cerebral hemodynamics in moyamoya disease: Correlation between perfusion-weighted MR imaging and cerebral angiography
    • Togao O, Mihara F, Yoshiura T, et al. Cerebral hemodynamics in moyamoya disease: Correlation between perfusion-weighted MR imaging and cerebral angiography. AJNR Am J Neuroradiol. 2006;27:391-397.
    • (2006) AJNR Am J Neuroradiol. , vol.27 , pp. 391-397
    • Togao, O.1    Mihara, F.2    Yoshiura, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.