메뉴 건너뛰기




Volumn 57, Issue 12, 2010, Pages 2695-2703

Lateral blood flow velocity estimation based on ultrasound speckle size change with scan velocity

Author keywords

[No Author keywords available]

Indexed keywords

AXIAL COMPONENTS; BLOOD FLOW; BLOOD FLOW VELOCITY; DOPPLER; ELECTRONICALLY-CONTROLLED; ESTIMATION ERRORS; ESTIMATION PERFORMANCE; FLOW DATA; FLOW GRADIENTS; LEAST SQUARE; LINEAR RELATIONSHIPS; MOVING CAMERAS; PULSE ECHOES; RANDOM MOTIONS; RED BLOOD CELL; SCAN VELOCITY; SINGLE IMAGES; SPATIAL LOCATION; SPECKLE DECORRELATION; SPECKLE PATTERNS; SPECKLE SIZE; STRETCH FACTOR; ULTRASOUND BEAMS; ULTRASOUND PROPAGATION; ULTRASOUND SPECKLE;

EID: 78650411133     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2010.1743     Document Type: Article
Times cited : (13)

References (18)
  • 1
    • 0027559559 scopus 로고
    • Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-A review
    • Mar
    • I. A. Hein and W. D. O'Brien Jr., "Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-A review," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 40, no. 2, pp. 84-102, Mar. 1993.
    • (1993) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.40 , Issue.2 , pp. 84-102
    • Hein, I.A.1    O'Brien Jr., W.D.2
  • 2
    • 78650401153 scopus 로고    scopus 로고
    • Apr. 23, [Online]. Available
    • American Stroke Association, (2010, Apr. 23) About Stroke, [Online]. Available: http://www.strokeassociation.org/STRO KEORG/ AboutStroke/About- Stroke-UCM-308529-SubHomePage.jsp
    • (2010) About Stroke
  • 3
    • 84939739865 scopus 로고
    • Real-time twodimensional blood flow imaging using an autocorrelation technique
    • C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, "Real-time twodimensional blood flow imaging using an autocorrelation technique," IEEE Trans. Sonics Ultrason., vol. 32, pp. 458-463, 1985.
    • (1985) IEEE Trans. Sonics Ultrason. , vol.32 , pp. 458-463
    • Kasai, C.1    Namekawa, K.2    Koyano, A.3    Omoto, R.4
  • 5
    • 0025577269 scopus 로고    scopus 로고
    • Invariance of Doppler bandwidth with flow axis displacement
    • V. L. Newhouse and J. Reid, "Invariance of Doppler bandwidth with flow axis displacement," in Proc. IEEE 1990 Ultrasonics Symp., vol. 2, pp. 1533-1536.
    • Proc. IEEE 1990 Ultrasonics Symp. , vol.2 , pp. 1533-1536
    • Newhouse, V.L.1    Reid, J.2
  • 6
    • 0032072540 scopus 로고    scopus 로고
    • Multi-dimensional velocity estimation with ultrasound using spatial quadrature
    • May
    • M. E. Anderson, "Multi-dimensional velocity estimation with ultrasound using spatial quadrature," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 45, no. 3, pp. 852-861, May 1998.
    • (1998) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.45 , Issue.3 , pp. 852-861
    • Anderson, M.E.1
  • 8
    • 0023526006 scopus 로고
    • Angle independent ultrasonic detection of blood flow
    • G. E. Trahey, J. W. Allison, and O. T. von Ramm, "Angle independent ultrasonic detection of blood flow," IEEE Trans. Biomed. Eng., vol. BME-34, no. 12, pp. 965-967, 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.BME-34 , Issue.12 , pp. 965-967
    • Trahey, G.E.1    Allison, J.W.2    Von Ramm, O.T.3
  • 9
    • 33751399679 scopus 로고    scopus 로고
    • Medical ultrasound imaging
    • J. A. Jensen, "Medical ultrasound imaging," Prog. Biophys. Mol. Biol., vol. 93, no. 1-3, pp. 153-165, 2007.
    • (2007) Prog. Biophys. Mol. Biol. , vol.93 , Issue.1-3 , pp. 153-165
    • Jensen, J.A.1
  • 12
    • 77950996724 scopus 로고    scopus 로고
    • Resolving the lateral component of blood flow velocity based on ultrasound speckle size change with scan direction and speed
    • Sep
    • T. Xu and G. R. Bashford, "Resolving the lateral component of blood flow velocity based on ultrasound speckle size change with scan direction and speed," in Proc. Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, vol. 3-6, Sep. 2009, pp. 491-494.
    • (2009) Proc. Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society , vol.3-6 , pp. 491-494
    • Xu, T.1    Bashford, G.R.2
  • 13
    • 77952869539 scopus 로고    scopus 로고
    • Further progress on lateral flow estimation using speckle size variation
    • T. Xu and G. R. Bashford, "Further progress on lateral flow estimation using speckle size variation," in Proc. 2009 IEEE Int. Ultrasonics Symp., pp.1383-1386.
    • Proc. 2009 IEEE Int. Ultrasonics Symp. , pp. 1383-1386
    • Xu, T.1    Bashford, G.R.2
  • 16
    • 0026838720 scopus 로고
    • Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
    • J. A. Jensen and N. B. Svendsen, "Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 39, pp. 262-267, 1992.
    • (1992) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.39 , pp. 262-267
    • Jensen, J.A.1    Svendsen, N.B.2
  • 17
    • 24044478820 scopus 로고    scopus 로고
    • Field: A program for simulating ultrasound systems
    • J. A. Jensen, "Field: A program for simulating ultrasound systems," Med. Biol. Eng. Comput., vol. 34, suppl. 1, pt. 1, pp. 351-353, 1996.
    • (1996) Med. Biol. Eng. Comput. , vol.34 , Issue.SUPPL. 1 PART 1 , pp. 351-353
    • Jensen, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.