메뉴 건너뛰기




Volumn 85, Issue 1, 2011, Pages 139-153

A prototype photovoltaic/thermal system integrated with transpired collector

Author keywords

Air preheating; Building integrated photovoltaic thermal system; Equivalent efficiency; Unglazed transpired collector

Indexed keywords

AIR PREHEATING; BUILDING ENVELOPES; BUILDING FACADES; BUILDING SURFACE; DEMONSTRATION PROJECT; EQUIVALENT EFFICIENCY; FRESH AIR; FULL SCALE; HEAT RECOVERY; HEATING SEASON; MONTREAL , CANADA; OPEN LOOPS; OUTDOOR AIR; PHOTOVOLTAIC SYSTEMS; PHOTOVOLTAIC/THERMAL; PHOTOVOLTAICS; PV MODULES; THERMAL EFFICIENCY; UNGLAZED TRANSPIRED COLLECTOR;

EID: 78650306942     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2010.10.008     Document Type: Article
Times cited : (116)

References (18)
  • 1
    • 78650304256 scopus 로고    scopus 로고
    • ASHRAE, ASHRAE Handbook of Fundamentals. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA, USA.
    • ASHRAE, 2009. ASHRAE Handbook of Fundamentals. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA, USA.
    • (2009)
  • 3
    • 33646156628 scopus 로고    scopus 로고
    • Optimization of the performance of double-facades with integrated photovoltaic panels and motorized blinds
    • Charron R., Athienitis A.K. Optimization of the performance of double-facades with integrated photovoltaic panels and motorized blinds. Solar Energy 2006, 80(5):482-491.
    • (2006) Solar Energy , vol.80 , Issue.5 , pp. 482-491
    • Charron, R.1    Athienitis, A.K.2
  • 4
    • 75449095088 scopus 로고    scopus 로고
    • A review of photovoltaic/thermal hybrid solar technology
    • Chow T.T. A review of photovoltaic/thermal hybrid solar technology. Applied Energy 2010, 87(2):365-379.
    • (2010) Applied Energy , vol.87 , Issue.2 , pp. 365-379
    • Chow, T.T.1
  • 5
    • 0141993367 scopus 로고    scopus 로고
    • Development of an approach to compare the 'value' of electric and thermal output from a domestic PV/thermal system
    • Coventry J.S., Lovegrove K. Development of an approach to compare the 'value' of electric and thermal output from a domestic PV/thermal system. Solar Energy 2003, 75(1):63-72.
    • (2003) Solar Energy , vol.75 , Issue.1 , pp. 63-72
    • Coventry, J.S.1    Lovegrove, K.2
  • 6
    • 78650308911 scopus 로고    scopus 로고
    • PVT unglazed corrugated transpired solar collector model. Canadian Solar Buildings Conference, June 2007, Calgary, Canada
    • Delisle, V., Collins, M.R., 2007. PVT unglazed corrugated transpired solar collector model. Canadian Solar Buildings Conference, June 2007, Calgary, Canada.
    • (2007)
    • Delisle, V.1    Collins, M.R.2
  • 7
    • 0030739336 scopus 로고    scopus 로고
    • Development of a flow distribution and design model for transpired solar collectors
    • Dymond C., Kutscher C.F. Development of a flow distribution and design model for transpired solar collectors. Solar Energy 1997, 60(5):291-300.
    • (1997) Solar Energy , vol.60 , Issue.5 , pp. 291-300
    • Dymond, C.1    Kutscher, C.F.2
  • 8
    • 29144447932 scopus 로고    scopus 로고
    • Photovoltaic collectors efficiency according to their integration in buildings
    • Guiavarch A., Peuportier B. Photovoltaic collectors efficiency according to their integration in buildings. Solar Energy 2006, 80(1):65-77.
    • (2006) Solar Energy , vol.80 , Issue.1 , pp. 65-77
    • Guiavarch, A.1    Peuportier, B.2
  • 9
    • 0037052334 scopus 로고    scopus 로고
    • Effect of wind in flow distribution in unglazed transpired plate collectors
    • Gunnewiek L.H., Brundett E., Hollands K.G.T. Effect of wind in flow distribution in unglazed transpired plate collectors. Solar Energy 2002, 72(4):317-325.
    • (2002) Solar Energy , vol.72 , Issue.4 , pp. 317-325
    • Gunnewiek, L.H.1    Brundett, E.2    Hollands, K.G.T.3
  • 10
    • 78650307863 scopus 로고    scopus 로고
    • IEA, Reliability study of grid connected PV systems. In: IEA PV Power Systems Program Report No. PVPS T7-08. Task 7.
    • IEA, 2002. Reliability study of grid connected PV systems. In: IEA PV Power Systems Program Report No. PVPS T7-08. Task 7.
    • (2002)
  • 11
    • 0028429880 scopus 로고
    • Heat exchanger effectiveness and pressure drop for air flow through perforated plates with and without crosswind
    • Kutscher C.F. Heat exchanger effectiveness and pressure drop for air flow through perforated plates with and without crosswind. Journal of Heat Transfer 1994, 116:391-399.
    • (1994) Journal of Heat Transfer , vol.116 , pp. 391-399
    • Kutscher, C.F.1
  • 14
    • 63449141127 scopus 로고    scopus 로고
    • On the temperature dependence of photovoltaic module electrical performance. A review of efficiency/power correlations
    • Skoplaki E., Palyvos J.A. On the temperature dependence of photovoltaic module electrical performance. A review of efficiency/power correlations. Solar Energy 2009, 83(5):614-624.
    • (2009) Solar Energy , vol.83 , Issue.5 , pp. 614-624
    • Skoplaki, E.1    Palyvos, J.A.2
  • 15
    • 78650306987 scopus 로고    scopus 로고
    • SOLARWALL, The SOLARWALL Solar Heating System. Conserval Engineering Inc., Canada. (accessed July 2009).
    • SOLARWALL, 2009. The SOLARWALL Solar Heating System. Conserval Engineering Inc., Canada. (accessed July 2009). http://www.solarwall.com/.
    • (2009)
  • 16
    • 0035843852 scopus 로고    scopus 로고
    • Heat-exchange relations for unglazed transpired solar collectors with circular holes on a square or triangular pitch
    • Van Decker G.W.E., Hollands K.G.T., Brunger A.P. Heat-exchange relations for unglazed transpired solar collectors with circular holes on a square or triangular pitch. Solar Energy 2001, 71(1):33-45.
    • (2001) Solar Energy , vol.71 , Issue.1 , pp. 33-45
    • Van Decker, G.W.E.1    Hollands, K.G.T.2    Brunger, A.P.3
  • 17
    • 0025431232 scopus 로고
    • Exergy conversion in the Japanese society
    • Wall G. Exergy conversion in the Japanese society. Energy 1990, 15(5):435-444.
    • (1990) Energy , vol.15 , Issue.5 , pp. 435-444
    • Wall, G.1
  • 18
    • 0026765128 scopus 로고
    • Effects of irradiance and other factors on PV temperature coefficients. In: Conference Record of the 22nd IEEE Photovoltaic Specialists Conference
    • Whitaker, C.M., Townsend, T.U., Wenger, H.J., Iliceto, A., Chimento, G., Paletta, F., 1991. Effects of irradiance and other factors on PV temperature coefficients. In: Conference Record of the 22nd IEEE Photovoltaic Specialists Conference, vol. 1, pp. 608-613.
    • (1991) , vol.1 , pp. 608-613
    • Whitaker, C.M.1    Townsend, T.U.2    Wenger, H.J.3    Iliceto, A.4    Chimento, G.5    Paletta, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.