메뉴 건너뛰기




Volumn 10, Issue 12, 2010, Pages 10837-10862

Detecting vital signs with wearablewireless sensors

Author keywords

BAN networks; On body sensors; RF sensing; Wearable sensors; Wireless telemetry

Indexed keywords

CHRONIC DISEASE MANAGEMENT; NON-INVASIVE MONITORING; ON-BODY; RESPIRATORY ACTIVITY; RF SENSING; WEARABLE SENSORS; WIRELESS TECHNOLOGIES; WIRELESS TELEMETRY;

EID: 78650301962     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s101210837     Document Type: Review
Times cited : (297)

References (79)
  • 2
    • 58149277008 scopus 로고    scopus 로고
    • Wireless body sensor networks for health-monitoring applications
    • Hao, Y.; Foster, R. Wireless body sensor networks for health-monitoring applications. Phys. Meas. 2008, 29, R27-R56.
    • (2008) Phys. Meas , vol.29 , pp. 27-56
    • Hao, Y.1    Foster, R.2
  • 3
    • 18044389554 scopus 로고    scopus 로고
    • Home blood glucose biosensors: A commercial perspective
    • Newman, J.D.; Turner, A.P.F. Home blood glucose biosensors: A commercial perspective. Biosens. Bioelectron. 2005, 20, 2435-2453.
    • (2005) Biosens. Bioelectron , vol.20 , pp. 2435-2453
    • Newman, J.D.1    Turner, A.P.F.2
  • 4
    • 33744501815 scopus 로고    scopus 로고
    • Ambulatory blood-pressure monitoring
    • Pickering, T.G.; Shimbo, D.; Hass, D. Ambulatory blood-pressure monitoring. N. Engl. J. Med. 2006, 354, 2368-2374.
    • (2006) N. Engl. J. Med , vol.354 , pp. 2368-2374
    • Pickering, T.G.1    Shimbo, D.2    Hass, D.3
  • 5
    • 0034483980 scopus 로고    scopus 로고
    • A Strategy for determination of systolic, mean and diastolic blood pressures from oscillometric pulse profiles
    • September 24-27
    • Moranes, J.C.T.B.; Cerulli, M.; Ng, P.S. A Strategy for Determination of Systolic, Mean and Diastolic Blood Pressures from Oscillometric Pulse Profiles. journal In Proceedings of Computers in Cardiology 2000, Cambridge, MA, USA, September 24-27, 2000; pp. 211-214.
    • (2000) Proceedings of Computers in Cardiology 2000 , pp. 211-214
    • Moranes, J.C.T.B.1    Cerulli, M.2    Ng, P.S.3
  • 6
    • 0032971217 scopus 로고    scopus 로고
    • Accuracy of radial artery blood pressure determination with the Vasotrac
    • Belani, K.G.; Buckley, J.J.; Poliac, M.O. Accuracy of radial artery blood pressure determination with the Vasotrac. Can. J. Anesth. 1999, 46, 488-496.
    • (1999) Can J. Anesth , vol.46 , pp. 488-496
    • Belani, K.G.1    Buckley, J.J.2    Poliac, M.O.3
  • 7
    • 25644432738 scopus 로고    scopus 로고
    • A comparison of radial artery blood pressure determination between the Vasotrac device and invasive arterial blood pressure monitoring in adolescents undergoing scoliosis surgery
    • McCann, M.E.; Hill, D.; Thomas, K.C.; Zurakowski, D.; Laussen, P.C. A comparison of radial artery blood pressure determination between the Vasotrac device and invasive arterial blood pressure monitoring in adolescents undergoing scoliosis surgery. Anesth. Analg. 2005, pp. 978-985.
    • (2005) Anesth. Analg , pp. 978-985
    • McCann, M.E.1    Hill, D.2    Thomas, K.C.3    Zurakowski, D.4    Laussen, P.C.5
  • 8
    • 0000212458 scopus 로고
    • Blood Flow Measured by doppler frequency shift of back-scattered ultrasound
    • Franklin, D.L.; Schlegel, W.; Rushme, R.F. Blood Flow Measured by doppler frequency shift of back-scattered ultrasound. Science 1961, 134, 564-565.
    • (1961) Science , vol.134 , pp. 564-565
    • Franklin, D.L.1    Schlegel, W.2    Rushme, R.F.3
  • 9
    • 0015711626 scopus 로고
    • Assessment of techniques for measurement of blood pressure in infants and children
    • Elseed, A.M.; Shinebourne, E.A.; Joseph, M.C. Assessment of techniques for measurement of blood pressure in infants and children. Dis. Child. 1973, 48, 932-936.
    • (1973) Dis. Child , vol.48 , pp. 932-936
    • Elseed, A.M.1    Shinebourne, E.A.2    Joseph, M.C.3
  • 10
    • 0017261204 scopus 로고
    • Pulse wave velocity as a measure of blood pressure change
    • Gribbin, B.; Steptoe, A.; Sleight, P. Pulse wave velocity as a measure of blood pressure change. Psychophysiology 1976, 3, 86-90.
    • (1976) Psychophysiology , vol.3 , pp. 86-90
    • Gribbin, B.1    Steptoe, A.2    Sleight, P.3
  • 12
    • 42749104783 scopus 로고    scopus 로고
    • M-Health: The development of cuff-less and wearable blood pressure meters for use in body sensor networks
    • IEEE/NLM, Bethesda, MD, USA, July
    • Poon, C.C.Y.; Wong, Y.M.; Zhang, Y.T. M-Health: The Development of Cuff-less and Wearable Blood Pressure Meters for Use in Body Sensor Networks. In Proceedings of Life Science Systems and Applications Workshop, IEEE/NLM, Bethesda, MD, USA, July 2006; pp. 1-2.
    • (2006) Proceedings of Life Science Systems and Applications Workshop , pp. 1-2
    • Poon, C.C.Y.1    Wong, Y.M.2    Zhang, Y.T.3
  • 14
    • 44349143355 scopus 로고    scopus 로고
    • Cuffless blood pressure monitoring using hydrostatic pressure changes
    • Shaltis, P.; Reisner, A.; Asada, H. Cuffless blood pressure monitoring using hydrostatic pressure changes. IEEE Trans. Biomed. Eng. 2008, 55, 1775-1777.
    • (2008) IEEE Trans. Biomed. Eng , vol.55 , pp. 1775-1777
    • Shaltis, P.1    Reisner, A.2    Asada, H.3
  • 16
    • 84876646958 scopus 로고    scopus 로고
    • Medtronic, Inc. Available online (accessed on 20 November 2010)
    • Medtronic Inc. Available online: http://www.medtronic.com/our-therapies/diabetes management/index.htm/ (accessed on 20 November 2010).
  • 18
    • 14844345011 scopus 로고    scopus 로고
    • Noninvasive and minimally invasive methods for transdermal glucose monitoring
    • Sieg, A.; Guy, R.H.; Delgado-Charro, M.B. Noninvasive and minimally invasive methods for transdermal glucose monitoring. Diabetes. Technol. Ther. 2005, 7, 174-197.
    • (2005) Diabetes. Technol. Ther , vol.7 , pp. 174-197
    • Sieg, A.1    Guy, R.H.2    Delgado-Charro, M.B.3
  • 19
    • 0037459111 scopus 로고    scopus 로고
    • Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes
    • Hayashi, Y.; Livshits, L.; Caduff, A.; Feldman, Y. Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes. J. Phys. D. Appl. Phys. 2003, 36, 369-374.
    • (2003) J. Phys. D. Appl. Phys , vol.36 , pp. 369-374
    • Hayashi, Y.1    Livshits, L.2    Caduff, A.3    Feldman, Y.4
  • 20
    • 0033119151 scopus 로고    scopus 로고
    • Hyponatremia: Evaluating the correction factor for hyperglycemia
    • Hillier, T.A.; Abbott, R.D.; Barrett, E.J. Hyponatremia: Evaluating the correction factor for hyperglycemia. Am. J. Med. 1999, 106, 399-403.
    • (1999) Am. J. Med , vol.106 , pp. 399-403
    • Hillier, T.A.1    Abbott, R.D.2    Barrett, E.J.3
  • 23
    • 64449088955 scopus 로고    scopus 로고
    • Non-invasive glucose monitoring in patients with Type 1 diabetes: A Multisensor system combining sensors for dielectric and optical characterisation of skin
    • Caduff, A.; Talary, M.S.; Mueller, M.; Dewarrat, F.; Klisic, J.; Donath, M.; Heinemann, L.; Stahel, W.A. Non-invasive glucose monitoring in patients with Type 1 diabetes: A Multisensor system combining sensors for dielectric and optical characterisation of skin. Biosens. Bioelectron. 2009, 24, 2778-2784.
    • (2009) Biosens. Bioelectron , vol.24 , pp. 2778-2784
    • Caduff, A.1    Talary, M.S.2    Mueller, M.3    Dewarrat, F.4    Klisic, J.5    Donath, M.6    Heinemann, L.7    Stahel, W.A.8
  • 24
    • 78650281450 scopus 로고    scopus 로고
    • The impact of glucose concentration in blood plasma on relative dielectric constant and conductivity
    • Boulder,CO, USA, January
    • Topsakal, E.; Moreland, E.C.; Karacolak, T.; Acar, M. The Impact of Glucose Concentration in Blood Plasma on Relative Dielectric Constant and Conductivity. In National Radio Science Meeting (USNC-URSI), Boulder,CO, USA, January 2008.
    • (2008) National Radio Science Meeting (USNC-URSI)
    • Topsakal, E.1    Moreland, E.C.2    Karacolak, T.3    Acar, M.4
  • 26
    • 78650287362 scopus 로고    scopus 로고
    • A Non-invasive Monitoring System
    • G.B. Patent 2428093, January, 17
    • Hancock, C.P. A Non-invasive Monitoring System. G.B. Patent 2428093, January 17, 2007.
    • (2007)
    • Hancock, C.P.A.1
  • 27
    • 78649760553 scopus 로고    scopus 로고
    • A microwave frequency sensor for non-invasive blood-glucose measurement
    • Atlanta, GA, USA, October
    • Jean, B.; Green, E.; McClung, M. A Microwave Frequency Sensor for Non-invasive Blood-glucose Measurement. In Sensors Applications Symposium, SAS 2008, Atlanta, GA, USA, October 2008; pp. 4-7.
    • (2008) Sensors Applications Symposium, SAS 2008 , pp. 4-7
    • Jean, B.1    Green, E.2    McClung, M.3
  • 28
    • 44849084269 scopus 로고    scopus 로고
    • Non-invasive measurement of blood-sugar level by reflection of millimeter-waves
    • APMC 2006, Yokohama, Japan, December
    • Nikawa, Y.; Michiyama, T. Non-invasive Measurement of Blood-sugar Level by Reflection of Millimeter-Waves. In Proceedings of Asia-Pacific Microwave Conference, APMC 2006, Yokohama, Japan, December 2006; pp. 47-50.
    • (2006) Proceedings of Asia-Pacific Microwave Conference , pp. 47-50
    • Nikawa, Y.1    Michiyama, T.2
  • 29
    • 51849098926 scopus 로고    scopus 로고
    • Blood-sugar monitoring by reflection of millimeter wave
    • Bangkok, Thailand, December
    • Nikawa, Y.; Michiyama, T. Blood-sugar Monitoring by Reflection of Millimeter Wave. In Proceedings of Asia-Pacific Microwave Conference, APMC 2007, Bangkok, Thailand, December 2007; pp. 1-4.
    • (2007) Proceedings of Asia-Pacific Microwave Conference , pp. 1-4
    • Nikawa, Y.1    Michiyama, T.2
  • 30
    • 0032065545 scopus 로고    scopus 로고
    • Phantom glucose calibration models from simulated noninvasive human near-infrared spectra
    • Arnold, M.A.; Burmeister, J.J.; Small, G.W. Phantom glucose calibration models from simulated noninvasive human near-infrared spectra. Anal. Chem. 1998, 70, 1773-1781.
    • (1998) Anal. Chem , vol.70 , pp. 1773-1781
    • Arnold, M.A.1    Burmeister, J.J.2    Small, G.W.3
  • 31
    • 66349130707 scopus 로고    scopus 로고
    • Turbidity-corrected raman spectroscopy for blood analyte detection
    • Barman, I.; Singh, G.P.; Dasari, R.R.; Feld, M.S. Turbidity-corrected raman spectroscopy for blood analyte detection. Anal. Chem. 2009, 81, 4233-4240.
    • (2009) Anal. Chem , vol.81 , pp. 4233-4240
    • Barman, I.1    Singh, G.P.2    Dasari, R.R.3    Feld, M.S.4
  • 32
    • 77954650164 scopus 로고    scopus 로고
    • Accurate spectroscopic calibration for noninvasive glucose monitoring by modeling the physiological glucose dynamics
    • Barman, I.; Kong, C.R.; Singh, G.P.; Dasari, R.R.; Feld, M.S. Accurate spectroscopic calibration for noninvasive glucose monitoring by modeling the physiological glucose dynamics. Anal. Chem. 2010, 82, 6104-6114.
    • (2010) Anal. Chem , vol.82 , pp. 6104-6114
    • Barman, I.1    Kong, C.R.2    Singh, G.P.3    Dasari, R.R.4    Feld, M.S.5
  • 33
    • 0032922153 scopus 로고    scopus 로고
    • The evolving role of ambulatory arrhythmia monitoring in general clinical practice
    • Zimetbaum, P.J.; Josephson, M.E. The evolving role of ambulatory arrhythmia monitoring in general clinical practice. Ann. Intern. Med. 1999, 130, 848-856.
    • (1999) Ann. Intern. Med , vol.130 , pp. 848-856
    • Zimetbaum, P.J.1    Josephson, M.E.2
  • 35
    • 0034048104 scopus 로고    scopus 로고
    • Direct comparison of wet, dry and insulating bioelectric recording electrodes
    • Searle, A.; Kirkup, L. A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol. Meas. 2000, 21, 271-283.
    • (2000) Physiol. Meas , vol.21 , pp. 271-283
    • Searle, A.1    Kirkup, L.A.2
  • 39
    • 1842527440 scopus 로고    scopus 로고
    • Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring
    • Droitcour, A.D.; Boric-Lubecke, O.; Lubecke, V.M.; Lin, J.; Kovacs, G.T.A. Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring. IEEE Trans. Microw. Theory Tech. 2004, 52, 838-848.
    • (2004) IEEE Trans. Microw. Theory Tech , vol.52 , pp. 838-848
    • Droitcour, A.D.1    Boric, L.O.2    Lubecke, V.M.3    Lin, J.4    Kovacs, G.T.A.5
  • 40
    • 78650299832 scopus 로고    scopus 로고
    • Unconstrained and noninvasive measurement of heartbeat and respiration for drivers using a strain gauge
    • Osaka, Japan, August
    • Matsubara, A.; Tanaka, S. Unconstrained and Noninvasive Measurement of Heartbeat and Respiration for Drivers using a Strain Gauge. In Proceedings of the 41st SICE Annual Conference, Osaka, Japan, August 2002; pp. 1067-1068.
    • (2002) Proceedings of the 41st SICE Annual Conference , pp. 1067-1068
    • Matsubara, A.1    Tanaka, S.2
  • 41
    • 77949456728 scopus 로고    scopus 로고
    • Wearable respiratory rate monitoring using piezo-resistive fabric sensor
    • Magjarevic, R., Nagel, J.H., D̈ossel, O., Schlegel, W.C., Eds., Springer:, Berlin/Heidelberg, Germany
    • Jeong, J.W.; Jang, Y.W.; Lee, I.; Shin, S.; Kim, S. Wearable Respiratory Rate Monitoring using Piezo-resistive Fabric Sensor. In World Congress on Medical Physics and Biomedical Engineering; Magjarevic, R., Nagel, J.H., D̈ossel, O., Schlegel, W.C., Eds.; Springer: Berlin/Heidelberg, Germany, 2009; pp. 282-284.
    • (2009) World Congress on Medical Physics and Biomedical Engineering , pp. 282-284
    • Jeong, J.W.1    Jang, Y.W.2    Lee, I.3    Shin, S.4    Kim, S.5
  • 43
    • 33644553999 scopus 로고    scopus 로고
    • Wearable eHealth systems for personalised health management: State of the art and future challenges
    • IOS Press: Fairfax, VA, USA, year
    • Grossman, P., Wearable eHealth Systems for Personalised Health Management: State of the Art and Future Challenges. In Wearable eHealth Systems for Personalised Health Management: State of the Art and Future Challenges; IOS Press: Fairfax, VA, USA, year? Volume 108, pp. 133-141.
    • Wearable EHealth Systems for Personalised Health Management: State of the Art and Future Challenges , vol.108 , pp. 133-141
    • Grossman, P.1
  • 44
    • 25844518552 scopus 로고    scopus 로고
    • A Wearable health care system based on knitted integrated sensors
    • Paradiso, R.; Loriga, G.; Taccini, N. A wearable health care system based on knitted integrated sensors. IEEE Trans. Inf. Technol. Biomed. 2005, 9, 337-344.
    • (2005) IEEE Trans. Inf. Technol. Biomed , vol.9 , pp. 337-344
    • Paradiso, R.1    Loriga, G.2    Taccini, N.3
  • 47
    • 84876653160 scopus 로고    scopus 로고
    • Bodymedia. Available online:(accessed on 20 November 2010)
    • Bodymedia. Available online: http://www.bodymedia.com/(accessed on 20 November 2010).
  • 48
    • 84876634642 scopus 로고    scopus 로고
    • Escort Guardian, Invivo Research. Available online:(accessed on 19 November 2010)
    • Escort Guardian, Invivo Research. Available online: http://www.invivoresearch.com/(accessed on 19 November 2010).
  • 49
    • 84876617845 scopus 로고    scopus 로고
    • Micropaq, Wellch Allyn. Available online (accessedon21November 2010)
    • Micropaq, Wellch Allyn. Available online: http://www.monitoring.welchallyn.com/(accessed on 21 November 2010).
  • 50
    • 84876656263 scopus 로고    scopus 로고
    • Sensatex, Available online (accessedon 20 November 2010)
    • Sensatex 2007. Available online: http://www.sensatex.com/(accessed on 20 November 2010).
    • (2007)
  • 52
    • 0030380805 scopus 로고    scopus 로고
    • Personal area networks: Near-field intrabody communication
    • Zimmerman, T.G. Personal Area Networks: Near-field intrabody communication. IBM Syst. J. 1996, 35, 609-617.
    • (1996) IBM Syst. J , vol.35 , pp. 609-617
    • Zimmerman, T.G.1
  • 53
    • 0030258579 scopus 로고    scopus 로고
    • Study of the handset antenna and human body interaction
    • Okoniewski, M.; Stuchly, M. A study of the handset antenna and human body interaction. IEEE Trans. Microw. Theory Tech. 1996, 44, 1855-1864.
    • (1996) IEEE Trans. Microw. Theory Tech , vol.44 , pp. 1855-1864
    • Okoniewski, M.1    Stuchly, M.A.2
  • 54
    • 0029745846 scopus 로고    scopus 로고
    • FDTD analysis of the handset antenna and human body interaction
    • MD, USA, July
    • Okoniewski, M.; Stuchly, M. FDTD Analysis of the Handset Antenna and Human Body Interaction. Vol. 3. In Antennas and Propagation Society International Symposium, 1996. AP-S. Digest, Baltimore, MD, USA, July 1996; pp. 1668-1673.
    • (1996) Antennas and Propagation Society International Symposium , vol.3 , pp. 1668-1673
    • Okoniewski, M.1    Stuchly, M.2
  • 55
    • 0032688573 scopus 로고    scopus 로고
    • Modelling of handset antenna interactions with the user and SAR reduction techniques
    • March, York, UK
    • Amos, S.; Smith, M.; Kitchener, D. Modelling of Handset Antenna Interactions with the User and SAR Reduction Techniques. In IEE National Conference on Antennas and Propagation, York, UK, March 1999; pp. 12-15.
    • (1999) IEE National Conference on Antennas and Propagation , pp. 12-15
    • Amos, S.1    Smith, M.2    Kitchener, D.3
  • 56
    • 0036822036 scopus 로고    scopus 로고
    • Resonator-based analysis of the combination of mobile handset antenna and chassis
    • Vainikainen, P.; Ollikainen, J.; Kivekas, O.; Kelander, K. Resonator-based analysis of the combination of mobile handset antenna and chassis. IEEE Trans. Antennas Propag. 2002, 50, 1433-1444.
    • (2002) IEEE Trans. Antennas Propag , vol.50 , pp. 1433-1444
    • Vainikainen, P.1    Ollikainen, J.2    Kivekas, O.3    Kelander, K.4
  • 58
    • 41849089788 scopus 로고    scopus 로고
    • Meandered double-PIFA antenna-handset/human interaction
    • MIKON 2006, Karakow, Poland, September
    • Krzysztofik, W. contributor Meandered Double-PIFA Antenna-Handset/Human Interaction. In International Conference on Microwaves, Radar Wireless Communications, MIKON 2006, Karakow, Poland, September 2006; pp. 119-122.
    • (2006) International Conference on Microwaves, Radar Wireless Communications , pp. 119-122
    • Krzysztofik, W.1
  • 59
    • 77950663676 scopus 로고    scopus 로고
    • Penta-band internal antenna for mobile handset
    • APMC 2009, Asia Pacific, Singapore, December
    • Cho, T.; Nam, S.; Lee, H. Penta-band Internal Antenna for Mobile Handset. In Microwave Conference, 2009. APMC 2009, Asia Pacific, Singapore, December 2009; pp. 2699-2702.
    • (2009) Microwave Conference, 2009 , pp. 2699-2702
    • Cho, T.1    Nam, S.2    Lee, H.3
  • 62
    • 73049087409 scopus 로고    scopus 로고
    • Survey on Wearable sensor-based systems for health monitoring and prognosis
    • Pantelopoulos, A.; Bourbakis, N. A survey on Wearable sensor-based systems for health monitoring and prognosis. IEEE Trans. Syst. Man. Cybern. 2010, 40, 1-12.
    • (2010) IEEE Trans. Syst. Man. Cybern , vol.40 , pp. 1-12
    • Pantelopoulos, A.1    Bourbakis, N.A.2
  • 63
    • 32544450307 scopus 로고    scopus 로고
    • UWB on-body radio propagation and system modelling for wireless body-centric networks
    • Alomainy, A.; Hao, Y.; Hu, X.; Parini, C.; Hall, P. UWB on-body radio propagation and system modelling for wireless body-centric networks. IEE Proc. Commun. 2006, 153, 107-114.
    • (2006) IEE Proc. Commun , vol.153 , pp. 107-114
    • Alomainy, A.1    Hao, Y.2    Hu, X.3    Parini, C.4    Hall, P.5
  • 64
    • 4043153400 scopus 로고    scopus 로고
    • Design of implantable microstrip antenna for communication with medical implants
    • Soontornpipit, P.; Furse, C.; Chung, Y.C. Design of implantable microstrip antenna for communication with medical implants. IEEE Trans. Microw. Theory Tech. 2004, 52, 1944-1951.
    • (2004) IEEE Trans. Microw. Theory Tech , vol.52 , pp. 1944-1951
    • Soontornpipit, P.1    Furse, C.2    Chung, Y.C.3
  • 65
    • 41949142111 scopus 로고    scopus 로고
    • Design of a dual-band implantable antenna and development of skin mimicking gels for continuous glucose monitoring
    • Karacolak, T.; Hood, A.; Topsakal, E. Design of a dual-band implantable antenna and development of skin mimicking gels for continuous glucose monitoring. IEEE Trans. Microw. Theory Tech. 2008, 56, 1001 -1008.
    • (2008) IEEE Trans. Microw. Theory Tech , vol.56 , pp. 1001-1008
    • Karacolak, T.1    Hood, A.2    Topsakal, E.3
  • 68
    • 77952374257 scopus 로고    scopus 로고
    • Wearable yagi microstrip antenna for telemedicine applications
    • New Orleans, LA, USA, January
    • Khaleel, H.; Al-Rizzo, H.; Rucker, D.; Elwi, T. Wearable Yagi Microstrip Antenna for Telemedicine Applications. In Radio and Wireless Symposium (RWS), New Orleans, LA, USA, January 2010; pp. 280-283.
    • (2010) Radio and Wireless Symposium (RWS) , pp. 280-283
    • Khaleel, H.1    Al-Rizzo, H.2    Rucker, D.3    Elwi, T.4
  • 71
    • 76149093555 scopus 로고    scopus 로고
    • A subject-specific radio propagation study in wireless body area networks
    • Loughborough, UK, November
    • Zhao, Y.; Sani, A.; Hao, Y.; Lee, S.; Yang, G. A Subject-Specific Radio Propagation Study in Wireless Body Area Networks. In Antennas Propagation Conference, LAPC 2009, Loughborough, UK, November 2009; pp. 80-83.
    • (2009) Antennas Propagation Conference, LAPC 2009 , pp. 80-83
    • Zhao, Y.1    Sani, A.2    Hao, Y.3    Lee, S.4    Yang, G.A.5
  • 72
    • 32544450307 scopus 로고    scopus 로고
    • UWB on-body radio propagation and system modelling for wireless body-centric networks
    • Alomainy, A.; Hao, Y.; Hu, X.; Parini, C.; Hall, P. UWB on-body radio propagation and system modelling for wireless body-centric networks. IEE Proc. Commun. 2006, 153, 107-114.
    • (2006) IEE Proc. Commun , vol.153 , pp. 107-114
    • Alomainy, A.1    Hao, Y.2    Hu, X.3    Parini, C.4    Hall, P.5
  • 73
    • 76249091071 scopus 로고    scopus 로고
    • Arm movements effect on ultra wideband on-body propagation channels and radio systems
    • Loughborough, UK, November
    • Abbasi, Q.; Sani, A.; Alomainy, A.; Hao, Y. Arm Movements Effect on Ultra Wideband on-body Propagation Channels and Radio Systems. In Antennas Propagation Conference, 2009. LAPC 2009, Loughborough, UK, November 2009; pp. 261-264.
    • (2009) Antennas Propagation Conference, 2009. LAPC 2009 , pp. 261-264
    • Abbasi, Q.1    Sani, A.2    Alomainy, A.3    Hao, Y.4
  • 78
    • 46649102297 scopus 로고    scopus 로고
    • Dual-resonant x003C0;-shape with double L-strips PIFA for implantable biotelemetry
    • Lee, C.M.; Yo, T.C.; Huang, F.J.; Luo, C.H. Dual-resonant x003C0;-shape with double L-strips PIFA for implantable biotelemetry. Electron. Lett. 2008, 44, 837-838.
    • (2008) Electron. Lett , vol.44 , pp. 837-838
    • Lee, C.M.1    Yo, T.C.2    Huang, F.J.3    Luo, C.H.4
  • 79
    • 77949999215 scopus 로고    scopus 로고
    • High frequency transcutaneous transmission using stents configured as a dipole radiator for cardiovascular implantable devices
    • Boston, MA, USA, June
    • Chow, E.; Beier, B.; Ouyang, Y.; Chappell, W.; Irazoqui, P. contributor High Frequency Transcutaneous Transmission Using Stents Configured as A Dipole Radiator for Cardiovascular Implantable Devices. In IEEE MTT-S International Microwave Symposium Digest, MTT'09, Boston, MA, USA, June 2009; pp. 1317-1320.
    • (2009) IEEE MTT-S International Microwave Symposium Digest, MTT'09 , pp. 1317-1320
    • Chow, E.1    Beier, B.2    Ouyang, Y.3    Chappell, W.4    Irazoqui, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.