메뉴 건너뛰기




Volumn 6443 LNCS, Issue PART 1, 2010, Pages 140-147

Stimulation of the retinal network in bionic vision devices: From multi-electrode arrays to pixelated vision

Author keywords

artificial vision; bionic vision; multi electrode array; neural prosthesis; retinal prosthesis

Indexed keywords

ACTIVE ELECTRODES; ARTIFICIAL VISION; ELECTRODE ARRAYS; FIELD CALCULATION; HEXAGONAL ARRAYS; HIGH DENSITY; HIGH-DENSITY ARRAYS; MICROELECTRODE ARRAY; MULTIELECTRODE ARRAYS; MULTIPLE ELECTRODES; NEURAL PROSTHESIS; NOVEL STRATEGIES; RETINAL NETWORK; RETINAL PROSTHESIS; SPATIAL FREQUENCY; STIMULATION SITES; TARGET CELLS; TARGET STRUCTURE; VISION IMPAIRED; VISUAL ACUITY; VISUAL PATTERN; VISUAL PERCEPTION;

EID: 78650219922     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-17537-4_18     Document Type: Conference Paper
Times cited : (11)

References (16)
  • 1
    • 1842530296 scopus 로고    scopus 로고
    • Causes and prevalence of visual impairment among adults in the United States
    • Congdon, N., et al.: Causes and prevalence of visual impairment among adults in the United States. Arch. Ophthalmol. 122, 477-485 (2004)
    • (2004) Arch. Ophthalmol. , vol.122 , pp. 477-485
    • Congdon, N.1
  • 2
    • 23144432156 scopus 로고    scopus 로고
    • Retinal remodeling during retinal degeneration
    • Jones, B.W., Marc, R.E.: Retinal remodeling during retinal degeneration. Exp. Eye Res. 81, 123-137 (2005)
    • (2005) Exp. Eye Res. , vol.81 , pp. 123-137
    • Jones, B.W.1    Marc, R.E.2
  • 3
    • 34247105448 scopus 로고    scopus 로고
    • Visual performance using a retinal prosthesis in three subjects with retinitis pigmentosa
    • Yanai, D., et al.: Visual performance using a retinal prosthesis in three subjects with retinitis pigmentosa. Am. J. Ophthalmol. 143, 820-827 (2007)
    • (2007) Am. J. Ophthalmol. , vol.143 , pp. 820-827
    • Yanai, D.1
  • 4
    • 53649104645 scopus 로고    scopus 로고
    • Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: Feasibility and outcome in seven patients
    • Besch, D., et al.: Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients. Br. J. Ophthalmol. 92, 1361-1368 (2008)
    • (2008) Br. J. Ophthalmol. , vol.92 , pp. 1361-1368
    • Besch, D.1
  • 5
    • 33847669848 scopus 로고    scopus 로고
    • Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit
    • Gerding, H., Benner, F.P., Taneri, S.: Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit. J. Neural Eng. 4, S38-S49 (2007)
    • (2007) J. Neural Eng. , vol.4
    • Gerding, H.1    Benner, F.P.2    Taneri, S.3
  • 7
    • 22044451448 scopus 로고    scopus 로고
    • A method and technical equipment for an acute human trial to evaluate retinal implant technology
    • Hornig, R., et al.: A method and technical equipment for an acute human trial to evaluate retinal implant technology. J. Neural Eng. 2, S129-S134 (2005)
    • (2005) J. Neural Eng. , vol.2
    • Hornig, R.1
  • 8
    • 20444454583 scopus 로고    scopus 로고
    • Cortical activation via an implanted wireless retinal prosthesis
    • Walter, P., et al.: Cortical activation via an implanted wireless retinal prosthesis. Invest Ophthalmol Vis. Sci. 46, 1780-1785 (2005)
    • (2005) Invest Ophthalmol Vis. Sci. , vol.46 , pp. 1780-1785
    • Walter, P.1
  • 9
    • 33847620366 scopus 로고    scopus 로고
    • Stimulation via a subretinally placed prosthetic elicits central activity and induces a trophic effect on visual responses
    • DeMarco Jr., P.J., et al.: Stimulation via a subretinally placed prosthetic elicits central activity and induces a trophic effect on visual responses. Invest Ophthalmol Vis. Sci. 48, 916-926 (2007)
    • (2007) Invest Ophthalmol Vis. Sci. , vol.48 , pp. 916-926
    • DeMarco Jr., P.J.1
  • 10
    • 77950422150 scopus 로고    scopus 로고
    • Subretinal microelectrode arrays implanted into blind retinitis pigmentosa patients allow recognition of letters and direction of thin stripes
    • Zrenner, E., et al.: Subretinal microelectrode arrays implanted into blind retinitis pigmentosa patients allow recognition of letters and direction of thin stripes. In: IFMBE Proceedings World Congress on Medical Physics and Biomedical Engineering, vol. 25, pp. 444-447 (2009)
    • (2009) IFMBE Proceedings World Congress on Medical Physics and Biomedical Engineering , vol.25 , pp. 444-447
    • Zrenner, E.1
  • 11
    • 69949167739 scopus 로고    scopus 로고
    • Visual acuity determined by landolt c test in a blind patient provided with a subretinal electronic implant
    • E-Abstract
    • Wilke, R., et al.: Visual acuity determined by landolt c test in a blind patient provided with a subretinal electronic implant. Invest. Ophthalmol. Vis. Sci. 2009 : E-Abstract (2009)
    • (2009) Invest. Ophthalmol. Vis. Sci. , vol.2009
    • Wilke, R.1
  • 13
    • 0037039812 scopus 로고    scopus 로고
    • Will retinal implants restore vision?
    • Zrenner, E.: Will retinal implants restore vision? Science 295, 1022-1025 (2002)
    • (2002) Science , vol.295 , pp. 1022-1025
    • Zrenner, E.1
  • 14
    • 68049131379 scopus 로고    scopus 로고
    • A CMOS retinal neurostimulator capable of focussed, simultaneous stimulation
    • Dommel, N.B., et al.: A CMOS retinal neurostimulator capable of focussed, simultaneous stimulation. J. Neural Eng. 6, 35006 (2009)
    • (2009) J. Neural Eng. , vol.6 , pp. 35006
    • Dommel, N.B.1
  • 15
    • 78650223520 scopus 로고    scopus 로고
    • Modeling advantages of subretinal microphotodiode-arrays utilizing sequential electrode activation
    • E-Abstract
    • Benav, H., Wilke, R., Stett, A., Zrenner, E.: Modeling advantages of subretinal microphotodiode-arrays utilizing sequential electrode activation. Invest. Ophthalmol. Vis. Sci. 2009 : E-Abstract (2009)
    • (2009) Invest. Ophthalmol. Vis. Sci. , vol.2009
    • Benav, H.1    Wilke, R.2    Stett, A.3    Zrenner, E.4
  • 16
    • 61849114018 scopus 로고    scopus 로고
    • Charge recovery during concurrent stimulation for a vision prosthesis
    • Addi, M.M., et al.: Charge recovery during concurrent stimulation for a vision prosthesis. In: Conf. Proc. IEEE Eng. Med. Biol. Soc. 2008, pp. 1797-1800 (2008)
    • (2008) Conf. Proc. IEEE Eng. Med. Biol. Soc. , vol.2008 , pp. 1797-1800
    • Addi, M.M.1