-
1
-
-
45849117984
-
The good, the bad, and the tiny: A review of microflow cytometry
-
Ateya DA, Erickson JS, Howell PB Jr, Hilliard LR, Golden JP, Ligler FS (2008) The good, the bad, and the tiny: a review of microflow cytometry. Anal Bioanal Chem 391:1485-1498
-
(2008)
Anal Bioanal Chem
, vol.391
, pp. 1485-1498
-
-
Ateya, D.A.1
Erickson, J.S.2
Howell Jr., P.B.3
Hilliard, L.R.4
Golden, J.P.5
Ligler, F.S.6
-
2
-
-
0034699375
-
Multiplexed particle-based flow cytometric assays
-
Vignali DA (2000) Multiplexed particle-based flow cytometric assays. J Immunol Meth 243:243-255
-
(2000)
J Immunol Meth
, vol.243
, pp. 243-255
-
-
Vignali, D.A.1
-
3
-
-
78650218536
-
-
www.millipore.com/flowcytometry/fc/fchome&open&cid=U0021
-
-
-
-
4
-
-
78650228265
-
-
www.accuricytometers.com/files/Accuri-Revolutionizes-Flow-Cytometry.pdf
-
-
-
-
6
-
-
80052094027
-
-
Kim JS, Ligler FS (eds), PanStanford Publishing, Singapore
-
Kim JS, Ligler FS (eds) (2010) The microflow cytometer. PanStanford Publishing, Singapore, 400pp
-
(2010)
The Microflow Cytometer
, pp. 400
-
-
-
7
-
-
78650224259
-
Surface modification and biomolecule immobilization on polymer spheres for biosensing applications
-
In Hurst SJ (ed), Springer, New York, In Press
-
Taitt CR, Shriver-Lake LC, Anderson GP, Ligler FS (2010) Surface modification and biomolecule immobilization on polymer spheres for biosensing applications. In: Hurst SJ (ed) Biomedical nanotechnology. Springer, New York, In Press
-
(2010)
Biomedical Nanotechnology
-
-
Taitt, C.R.1
Shriver-Lake, L.C.2
Anderson, G.P.3
Ligler, F.S.4
-
8
-
-
0017666267
-
Quantitative single cell analysis and sorting
-
Horan PK, Wheeless LL Jr (1977) Quantitative single cell analysis and sorting. Science 198:149-157
-
(1977)
Science
, vol.198
, pp. 149-157
-
-
Horan, P.K.1
Wheeless Jr., L.L.2
-
9
-
-
0032698678
-
Particle classification from light scattering with the scanning flow cytometer
-
Shvalov AN, Surovtsev IV, Chernyshev AV, Soini JT, Maltsev VP (1999) Particle classification from light scattering with the scanning flow cytometer. Cytometry 37:215-220
-
(1999)
Cytometry
, vol.37
, pp. 215-220
-
-
Shvalov, A.N.1
Surovtsev, I.V.2
Chernyshev, A.V.3
Soini, J.T.4
Maltsev, V.P.5
-
11
-
-
0025257412
-
Light scattering measurement in an arc lampbased flow cytometer
-
Steen HB (1990) Light scattering measurement in an arc lampbased flow cytometer. Cytometry 11:223-230
-
(1990)
Cytometry
, vol.11
, pp. 223-230
-
-
Steen, H.B.1
-
12
-
-
1042279518
-
Flow cytometer for measurement of the light scattering of viral and other submicroscopic particles
-
Steen HB (2004) Flow cytometer for measurement of the light scattering of viral and other submicroscopic particles. Cytom A 57:94-99
-
(2004)
Cytom A
, vol.57
, pp. 94-99
-
-
Steen, H.B.1
-
13
-
-
0019407645
-
Automated particle-counting immunoassay for digoxin
-
Colletcassart D, Magnusson CGM, Cambiaso CL, Lesne M, Masson PL (1981) Automated particle-counting immunoassay for digoxin. Clin Chem 27:1205-1209
-
(1981)
Clin Chem
, vol.27
, pp. 1205-1209
-
-
Colletcassart, D.1
Magnusson, C.G.M.2
Cambiaso, C.L.3
Lesne, M.4
Masson, P.L.5
-
14
-
-
0020586561
-
Automated particle-counting immunoassay of creactive protein and its application to serum, cord serum, and cerebrospinal-fluid samples
-
Colletcassart D, Mareschal JC, Sindic CJM, Tomasi JP, Masson PL (1983) Automated particle-counting immunoassay of Creactive protein and its application to serum, cord serum, and cerebrospinal-fluid samples. Clin Chem 29:1127-1131
-
(1983)
Clin Chem
, vol.29
, pp. 1127-1131
-
-
Colletcassart, D.1
Mareschal, J.C.2
Sindic, C.J.M.3
Tomasi, J.P.4
Masson, P.L.5
-
15
-
-
0022239279
-
Particle-counting immunoassay of a fetuin-like antigen in serum and cerebrospinal-fluid
-
Fagnart OC, Cambiaso CL, Sindic CJM, Masson PL (1985) Particle-counting immunoassay of a fetuin-like antigen in serum and cerebrospinal-fluid. Clin Chem 31:1820-1823
-
(1985)
Clin Chem
, vol.31
, pp. 1820-1823
-
-
Fagnart, O.C.1
Cambiaso, C.L.2
Sindic, C.J.M.3
Masson, P.L.4
-
16
-
-
0021434403
-
Particle-counting immunoassay of human somatotropin
-
Castracane CE, Cambiaso CL, Retegui LA, Gilbert I, Ketelslegers JM, Masson PL (1984) Particle-counting immunoassay of human somatotropin. Clin Chem 30:672-676
-
(1984)
Clin Chem
, vol.30
, pp. 672-676
-
-
Castracane, C.E.1
Cambiaso, C.L.2
Retegui, L.A.3
Gilbert, I.4
Ketelslegers, J.M.5
Masson, P.L.6
-
17
-
-
2342562444
-
Counting and sizing of particles and particle agglomerates in a microfluidic device using laser light scattering: Application to a particle-enhanced immunoassay
-
Pamme N, Koyama R, Manz A (2003) Counting and sizing of particles and particle agglomerates in a microfluidic device using laser light scattering: application to a particle-enhanced immunoassay. Lab Chip 3:187-192
-
(2003)
Lab Chip
, vol.3
, pp. 187-192
-
-
Pamme, N.1
Koyama, R.2
Manz, A.3
-
18
-
-
0001194259
-
High speed automatic blood cell counter and cell size analyzer
-
Coulter WH (1956) High speed automatic blood cell counter and cell size analyzer. Proc Natl Electron Conf 12:1034-1040
-
(1956)
Proc Natl Electron Conf
, vol.12
, pp. 1034-1040
-
-
Coulter, W.H.1
-
19
-
-
75549115525
-
Time-saving method for blood cell counting with the coulter counter
-
Maeurer HC (1964) Time-saving method for blood cell counting with the coulter counter. Bibl Haematol 18:19-20
-
(1964)
Bibl Haematol
, vol.18
, pp. 19-20
-
-
Maeurer, H.C.1
-
20
-
-
73649190244
-
Observations on the use of the Coulter model D electronic cell counter in clinical haematology
-
Blades AN, Flavell HC (1963) Observations on the use of the Coulter model D electronic cell counter in clinical haematology. J Clin Pathol 16:158-163
-
(1963)
J Clin Pathol
, vol.16
, pp. 158-163
-
-
Blades, A.N.1
Flavell, H.C.2
-
23
-
-
0033101199
-
Electric impedance spectroscopy using microchannels with integrated metal electrodes
-
Ayliffe HE, Frazier AB, Rabbitt RD (1999) Electric impedance spectroscopy using microchannels with integrated metal electrodes. J Microelectromech Syst 8:50-57
-
(1999)
J Microelectromech Syst
, vol.8
, pp. 50-57
-
-
Ayliffe, H.E.1
Frazier, A.B.2
Rabbitt, R.D.3
-
24
-
-
19444377196
-
Impedance spectroscopy flow cytometry: On-chip label-free cell differentiation
-
Cheung K, Gawad S, Renaud P (2005) Impedance spectroscopy flow cytometry: on-chip label-free cell differentiation. Cytom A 65:124-132
-
(2005)
Cytom A
, vol.65
, pp. 124-132
-
-
Cheung, K.1
Gawad, S.2
Renaud, P.3
-
25
-
-
3142726971
-
Dielectric spectroscopy in a micromachined flow cytometer: Theoretical and practical considerations
-
Gawad S, Cheung K, Seger U, Bertsch A, Renaud P (2004) Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations. Lab Chip 4:241-251
-
(2004)
Lab Chip
, vol.4
, pp. 241-251
-
-
Gawad, S.1
Cheung, K.2
Seger, U.3
Bertsch, A.4
Renaud, P.5
-
26
-
-
0141989814
-
Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing
-
Gawad S, Schild L, Renaud PH (2001) Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. Lab Chip 1:76-82
-
(2001)
Lab Chip
, vol.1
, pp. 76-82
-
-
Gawad, S.1
Schild, L.2
Renaud, P.H.3
-
27
-
-
34547110362
-
High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequences
-
Sun T, Holmes D, Gawad S, Green NG, Morgan H (2007) High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequences. Lab Chip 7:1034-1040
-
(2007)
Lab Chip
, vol.7
, pp. 1034-1040
-
-
Sun, T.1
Holmes, D.2
Gawad, S.3
Green, N.G.4
Morgan, H.5
-
28
-
-
84931767500
-
Impedance of a suspension of ballshaped particles with a shell; a model for the dielectric behavior of cell suspensions and protein solutions
-
Pauly H, Schwan HP (1959) Impedance of a suspension of ballshaped particles with a shell; a model for the dielectric behavior of cell suspensions and protein solutions. Z Naturforsch B 14B:125-131
-
(1959)
Z Naturforsch B
, vol.14 B
, pp. 125-131
-
-
Pauly, H.1
Schwan, H.P.2
-
29
-
-
0024561015
-
Dielectric properties of mouse lymphocytes and erythrocytes
-
Asami K, Takahashi Y, Takashima S (1989) Dielectric properties of mouse lymphocytes and erythrocytes. Biochim Biophys Acta 1010:49-55
-
(1989)
Biochim Biophys Acta
, vol.1010
, pp. 49-55
-
-
Asami, K.1
Takahashi, Y.2
Takashima, S.3
-
30
-
-
34547111796
-
Bead-based immunoassays using a micro-chip flow cytometer
-
Holmes D, She JK, Roach PL, Morgan H (2007) Bead-based immunoassays using a micro-chip flow cytometer. Lab Chip 7:1048-1056
-
(2007)
Lab Chip
, vol.7
, pp. 1048-1056
-
-
Holmes, D.1
She, J.K.2
Roach, P.L.3
Morgan, H.4
-
31
-
-
0030776426
-
Advanced multiplexed analysis with the FlowMetrix system
-
Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr (1997) Advanced multiplexed analysis with the FlowMetrix system. Clin Chem 43:1749-1756
-
(1997)
Clin Chem
, vol.43
, pp. 1749-1756
-
-
Fulton, R.J.1
McDade, R.L.2
Smith, P.L.3
Kienker, L.J.4
Kettman Jr., J.R.5
-
32
-
-
0032856945
-
Simultaneous Quantitation of 15 cytokines using a multiplexed flow cytometric assay
-
Carson RT, Vignali DA (1999) Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Meth 227:41-52
-
(1999)
J Immunol Meth
, vol.227
, pp. 41-52
-
-
Carson, R.T.1
Vignali, D.A.2
-
33
-
-
0032738825
-
A microfabricated fluorescence-activated cell sorter
-
Fu AY, Spence C, Scherer A, Arnold FH, Quake SR (1999) A microfabricated fluorescence-activated cell sorter. Nat Biotechnol 17:1109-1111
-
(1999)
Nat Biotechnol
, vol.17
, pp. 1109-1111
-
-
Fu, A.Y.1
Spence, C.2
Scherer, A.3
Arnold, F.H.4
Quake, S.R.5
-
34
-
-
10944242630
-
Vertical focusing device utilizing dielectrophoretic force and its application on microflow cytometer
-
Lin CH, Lee GB, Fu LM, Hwey BH (2004) Vertical focusing device utilizing dielectrophoretic force and its application on microflow cytometer. J Microelectromechanical Syst 13:923-932
-
(2004)
J Microelectromechanical Syst
, vol.13
, pp. 923-932
-
-
Lin, C.H.1
Lee, G.B.2
Fu, L.M.3
Hwey, B.H.4
-
35
-
-
31044451561
-
High throughput particle analysis: Combining dielectrophoretic particle focusing with confocal optical detection
-
Holmes D, Morgan H, Green NG (2006) High throughput particle analysis: combining dielectrophoretic particle focusing with confocal optical detection. Biosens Bioelectron 21:1621-1630
-
(2006)
Biosens Bioelectron
, vol.21
, pp. 1621-1630
-
-
Holmes, D.1
Morgan, H.2
Green, N.G.3
-
36
-
-
33747608896
-
High-throughput and highresolution flow cytometry in molded microfluidic devices
-
Simonnet C, Groisman A (2006) High-throughput and highresolution flow cytometry in molded microfluidic devices. Anal Chem 78:5653-5663
-
(2006)
Anal Chem
, vol.78
, pp. 5653-5663
-
-
Simonnet, C.1
Groisman, A.2
-
37
-
-
67649997689
-
Multiplexed detection of bacteria and toxins using a microflow cytometer
-
Kim JS, Anderson GP, Erickson JS, Golden JP, Nasir M, Ligler FS (2009) Multiplexed detection of bacteria and toxins using a microflow cytometer. Anal Chem 81:5426-5432
-
(2009)
Anal Chem
, vol.81
, pp. 5426-5432
-
-
Kim, J.S.1
Anderson, G.P.2
Erickson, J.S.3
Golden, J.P.4
Nasir, M.5
Ligler, F.S.6
-
38
-
-
67649933627
-
Multi-wavelength microflow cytometer using groove-generated sheath flow
-
Golden JP, Kim JS, Erickson JS, Hilliard LR, Howell PB, Anderson GP et al (2009) Multi-wavelength microflow cytometer using groove-generated sheath flow. Lab Chip 9:1942-1950
-
(2009)
Lab Chip
, vol.9
, pp. 1942-1950
-
-
Golden, J.P.1
Kim, J.S.2
Erickson, J.S.3
Hilliard, L.R.4
Howell, P.B.5
Anderson, G.P.6
-
39
-
-
77949615835
-
Microfluidic applications of magnetic particles for biological analysis and catalysis
-
doi:10.1021/cr9001929
-
Gijs MA, Lacharme F, Lehmann U (2009) Microfluidic applications of magnetic particles for biological analysis and catalysis. Chem Rev. doi:10.1021/cr9001929
-
(2009)
Chem Rev
-
-
Gijs, M.A.1
Lacharme, F.2
Lehmann, U.3
-
40
-
-
18144408144
-
Magnetophoresis and electromagnetophoresis of microparticles in liquids
-
Watarai H, Suwa M, Iiguni Y (2004) Magnetophoresis and electromagnetophoresis of microparticles in liquids. Anal Bioanal Chem 378:1693-1699
-
(2004)
Anal Bioanal Chem
, vol.378
, pp. 1693-1699
-
-
Watarai, H.1
Suwa, M.2
Iiguni, Y.3
-
41
-
-
0034757127
-
Magnetophoretic behavior of single polystyrene particles in aqueous manganese(II) chloride
-
Watarai H, Namba M (2001) Magnetophoretic behavior of single polystyrene particles in aqueous manganese(II) chloride. Anal Sci 17:1233-1236
-
(2001)
Anal Sci
, vol.17
, pp. 1233-1236
-
-
Watarai, H.1
Namba, M.2
-
42
-
-
0037188758
-
Capillary magnetophoresis of human blood cells and their magnetophoretic trapping in a flow system
-
Watarai H, Namba M (2002) Capillary magnetophoresis of human blood cells and their magnetophoretic trapping in a flow system. J Chromatogr A 961:3-8
-
(2002)
J Chromatogr A
, vol.961
, pp. 3-8
-
-
Watarai, H.1
Namba, M.2
-
43
-
-
32544439539
-
Synthesis of magnetic nanoparticles and their application to bioassays
-
Osaka T, Matsunaga T, Nakanishi T, Arakaki A, Niwa D, Iida H (2006) Synthesis of magnetic nanoparticles and their application to bioassays. Anal Bioanal Chem 384:593-600
-
(2006)
Anal Bioanal Chem
, vol.384
, pp. 593-600
-
-
Osaka, T.1
Matsunaga, T.2
Nakanishi, T.3
Arakaki, A.4
Niwa, D.5
Iida, H.6
-
44
-
-
34547510568
-
Synthesis of Fe3O4 nanoparticles with various sizes and magnetic properties by controlled hydrolysis
-
Iida H, Takayanagi K, Nakanishi T, Osaka T (2007) Synthesis of Fe3O4 nanoparticles with various sizes and magnetic properties by controlled hydrolysis. J Colloid Interface Sci 314:274-280
-
(2007)
J Colloid Interface Sci
, vol.314
, pp. 274-280
-
-
Iida, H.1
Takayanagi, K.2
Nakanishi, T.3
Osaka, T.4
-
45
-
-
27944496941
-
Cell-specific targeting of nanoparticles by multivalent attachment of small molecules
-
Weissleder R, Kelly K, Sun EY, Shtatland T, Josephson L (2005) Cell-specific targeting of nanoparticles by multivalent attachment of small molecules. Nat Biotechnol 23:1418-1423
-
(2005)
Nat Biotechnol
, vol.23
, pp. 1418-1423
-
-
Weissleder, R.1
Kelly, K.2
Sun, E.Y.3
Shtatland, T.4
Josephson, L.5
-
46
-
-
34347222593
-
Binding of biological effectors on magnetic nanoparticles measured by a magnetically induced transient birefringence experiment
-
Wilhelm C, Gazeau F, Roger J, Pons JN, Salis MF, Perzynski R et al (2002) Binding of biological effectors on magnetic nanoparticles measured by a magnetically induced transient birefringence experiment. Phys Rev E Stat Nonlin Soft Matter Phys 65:031404
-
(2002)
Phys Rev E Stat Nonlin Soft Matter Phys
, vol.65
, pp. 031404
-
-
Wilhelm, C.1
Gazeau, F.2
Roger, J.3
Pons, J.N.4
Salis, M.F.5
Perzynski, R.6
-
47
-
-
0036586093
-
Magnetophoresis and ferromagnetic resonance of magnetically labeled cells
-
Wilhelm C, Gazeau F, Bacri JC (2002) Magnetophoresis and ferromagnetic resonance of magnetically labeled cells. Eur Biophys J 31:118-125
-
(2002)
Eur Biophys J
, vol.31
, pp. 118-125
-
-
Wilhelm, C.1
Gazeau, F.2
Bacri, J.C.3
-
48
-
-
0242526952
-
Deformation of intracellular endosomes under a magnetic field
-
Wilhelm C, Cebers A, Bacri JC, Gazeau F (2003) Deformation of intracellular endosomes under a magnetic field. Eur Biophys J 32:655-660
-
(2003)
Eur Biophys J
, vol.32
, pp. 655-660
-
-
Wilhelm, C.1
Cebers, A.2
Bacri, J.C.3
Gazeau, F.4
-
49
-
-
0037334220
-
Intracellular uptake of anionic superparamagnetic nanoparticles as a function of their surface coating
-
Wilhelm C, Billotey C, Roger J, Pons JN, Bacri JC, Gazeau F (2003) Intracellular uptake of anionic superparamagnetic nanoparticles as a function of their surface coating. Biomaterials 24:1001-1011
-
(2003)
Biomaterials
, vol.24
, pp. 1001-1011
-
-
Wilhelm, C.1
Billotey, C.2
Roger, J.3
Pons, J.N.4
Bacri, J.C.5
Gazeau, F.6
-
50
-
-
33847723425
-
Size-sorted anionic iron oxide nanomagnets as colloidal mediators for magnetic hyperthermia
-
Fortin JP, Wilhelm C, Servais J, Menager C, Bacri JC, Gazeau F (2007) Size-sorted anionic iron oxide nanomagnets as colloidal mediators for magnetic hyperthermia. J Am Chem Soc 129:2628-2635
-
(2007)
J Am Chem Soc
, vol.129
, pp. 2628-2635
-
-
Fortin, J.P.1
Wilhelm, C.2
Servais, J.3
Menager, C.4
Bacri, J.C.5
Gazeau, F.6
-
51
-
-
0037381123
-
Cell internalization of anionic maghemite nanoparticles: Quantitative effect on magnetic resonance imaging
-
Billotey C, Wilhelm C, Devaud M, Bacri JC, Bittoun J, Gazeau F (2003) Cell internalization of anionic maghemite nanoparticles: quantitative effect on magnetic resonance imaging. Magn Reson Med 49:646-654
-
(2003)
Magn Reson Med
, vol.49
, pp. 646-654
-
-
Billotey, C.1
Wilhelm, C.2
Devaud, M.3
Bacri, J.C.4
Bittoun, J.5
Gazeau, F.6
-
52
-
-
10644278990
-
On-chip free-flow magnetophoresis: Continuous flow separation of magnetic particles and agglomerates
-
Pamme N, Manz A (2004) On-chip free-flow magnetophoresis: continuous flow separation of magnetic particles and agglomerates. Anal Chem 76:7250-7256
-
(2004)
Anal Chem
, vol.76
, pp. 7250-7256
-
-
Pamme, N.1
Manz, A.2
-
53
-
-
70449090303
-
Mobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow
-
Peyman SA, Iles A, Pamme N (2009) Mobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow. Lab Chip 9:3110-3117
-
(2009)
Lab Chip
, vol.9
, pp. 3110-3117
-
-
Peyman, S.A.1
Iles, A.2
Pamme, N.3
-
54
-
-
20844434014
-
Magnetic force-based multiplexed immunoassay using superparamagnetic nanoparticles in microfluidic channel
-
Kim KS, Park JK (2005) Magnetic force-based multiplexed immunoassay using superparamagnetic nanoparticles in microfluidic channel. Lab Chip 5:657-664
-
(2005)
Lab Chip
, vol.5
, pp. 657-664
-
-
Kim, K.S.1
Park, J.K.2
-
55
-
-
33947412001
-
Magnetophoretic immunoassay of allergen-specific IgE in an enhanced magnetic field gradient
-
Hahn YK, Jin Z, Kang JH, Oh E, Han MK, Kim HS, et al (2007) Magnetophoretic immunoassay of allergen-specific IgE in an enhanced magnetic field gradient. Anal Chem 2214-2220
-
(2007)
Anal Chem
, pp. 2214-2220
-
-
Hahn, Y.K.1
Jin, Z.2
Kang, J.H.3
Oh, E.4
Han, M.K.5
Kim, H.S.6
-
56
-
-
60349127252
-
Magnetophoretic position detection for multiplexed immunoassay using colored microspheres in a microchannel
-
Hahn YK, Chang JB, Jin Z, Kim HS, Park JK (2009) Magnetophoretic position detection for multiplexed immunoassay using colored microspheres in a microchannel. Biosens Bioelectron 24:1870-1876
-
(2009)
Biosens Bioelectron
, vol.24
, pp. 1870-1876
-
-
Hahn, Y.K.1
Chang, J.B.2
Jin, Z.3
Kim, H.S.4
Park, J.K.5
-
57
-
-
67549088806
-
Micro flow cytometry utilizing a magnetic bead-based immunoassay for rapid virus detection
-
Yang SY, Lien KY, Huang KJ, Lei HY, Lee GB (2008) Micro flow cytometry utilizing a magnetic bead-based immunoassay for rapid virus detection. Biosens Bioelectron 24:861-868
-
(2008)
Biosens Bioelectron
, vol.24
, pp. 861-868
-
-
Yang, S.Y.1
Lien, K.Y.2
Huang, K.J.3
Lei, H.Y.4
Lee, G.B.5
-
58
-
-
70350393261
-
An integrated microfluidic system for rapid diagnosis of dengue virus infection
-
Lee YF, Lien KY, Lei HY, Lee GB (2009) An integrated microfluidic system for rapid diagnosis of dengue virus infection. Biosens Bioelectron 25:745-752
-
(2009)
Biosens Bioelectron
, vol.25
, pp. 745-752
-
-
Lee, Y.F.1
Lien, K.Y.2
Lei, H.Y.3
Lee, G.B.4
|