-
1
-
-
0036480113
-
The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length
-
A. ElAyouti, R. Weiger, and C. Lost The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length J Endod 28 2002 116 119
-
(2002)
J Endod
, vol.28
, pp. 116-119
-
-
Elayouti, A.1
Weiger, R.2
Lost, C.3
-
2
-
-
0030114942
-
Comparison of radiographic and electronic working lengths
-
D.H. Pratten, and N.J. McDonald Comparison of radiographic and electronic working lengths J Endod 22 1996 173 176
-
(1996)
J Endod
, vol.22
, pp. 173-176
-
-
Pratten, D.H.1
McDonald, N.J.2
-
4
-
-
33745809484
-
The fundamental operating principles of electronic root canal length measurement devices
-
M.H. Nekoofar, M.M. Ghandi, S.J. Hayes, and P.M. Dummer The fundamental operating principles of electronic root canal length measurement devices Int Endod J 39 2006 595 609
-
(2006)
Int Endod J
, vol.39
, pp. 595-609
-
-
Nekoofar, M.H.1
Ghandi, M.M.2
Hayes, S.J.3
Dummer, P.M.4
-
6
-
-
0030275701
-
An in vivo evaluation of Root ZX electronic apex locator
-
S. Shabahang, W.W. Goon, and A.H. Gluskin An in vivo evaluation of Root ZX electronic apex locator J Endod 22 1996 616 618
-
(1996)
J Endod
, vol.22
, pp. 616-618
-
-
Shabahang, S.1
Goon, W.W.2
Gluskin, A.H.3
-
7
-
-
22244463551
-
An evaluation of root ZX and elements diagnostic apex locators
-
M. Tselnik, J.C. Baumgartner, and J.G. Marshall An evaluation of root ZX and elements diagnostic apex locators J Endod 31 2005 507 509
-
(2005)
J Endod
, vol.31
, pp. 507-509
-
-
Tselnik, M.1
Baumgartner, J.C.2
Marshall, J.G.3
-
8
-
-
33947130655
-
Influence of embedding media on the assessment of electronic apex locators
-
J.V. Baldi, F.R. Victorino, and R.A. Bernardes Influence of embedding media on the assessment of electronic apex locators J Endod 33 2007 476 479
-
(2007)
J Endod
, vol.33
, pp. 476-479
-
-
Baldi, J.V.1
Victorino, F.R.2
Bernardes, R.A.3
-
9
-
-
67649198048
-
An in vivo comparison of the Root ZX II, the Apex NRG XFR, and Mini Apex Locator by using rotary nickel-titanium files
-
C. Siu, J.G. Marshall, and J.C. Baumgartner An in vivo comparison of the Root ZX II, the Apex NRG XFR, and Mini Apex Locator by using rotary nickel-titanium files J Endod 35 2009 962 965
-
(2009)
J Endod
, vol.35
, pp. 962-965
-
-
Siu, C.1
Marshall, J.G.2
Baumgartner, J.C.3
-
10
-
-
70349855094
-
An in vivo comparison of working length determination of two frequency-based electronic apex locators
-
E.A. Pascon, M. Marrelli, O. Congi, R. Ciancio, F. Miceli, and M.A. Versiani An in vivo comparison of working length determination of two frequency-based electronic apex locators Int Endod J 42 2009 1026 1031
-
(2009)
Int Endod J
, vol.42
, pp. 1026-1031
-
-
Pascon, E.A.1
Marrelli, M.2
Congi, O.3
Ciancio, R.4
Miceli, F.5
Versiani, M.A.6
-
11
-
-
0000324382
-
Apical limit of root canal instrumentation and obturation, part 2. A histological study
-
D. Ricucci, and K. Langeland Apical limit of root canal instrumentation and obturation, part 2: a histological study Int Endod J 31 1998 394 409 (Pubitemid 128497692)
-
(1998)
International Endodontic Journal
, vol.31
, Issue.6
, pp. 394-409
-
-
Ricucci, D.1
Langeland, K.2
-
12
-
-
0021504490
-
The position and topography of the apical canal constriction and apical foramen
-
P.M. Dummer, J.H. McGinn, and D.G. Rees The position and topography of the apical canal constriction and apical foramen Int Endod J 17 1984 192 198
-
(1984)
Int Endod J
, vol.17
, pp. 192-198
-
-
Dummer, P.M.1
McGinn, J.H.2
Rees, D.G.3
-
13
-
-
0036777042
-
Clinical accuracy of a new apex locator with an automatic compensation circuit
-
S.J. Lee, K.C. Nam, Y.J. Kim, and D.W. Kim Clinical accuracy of a new apex locator with an automatic compensation circuit J Endod 28 2002 706 709
-
(2002)
J Endod
, vol.28
, pp. 706-709
-
-
Lee, S.J.1
Nam, K.C.2
Kim, Y.J.3
Kim, D.W.4
-
14
-
-
0027700136
-
In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator
-
D.L. Mayeda, J.H. Simon, D.F. Aimar, and K. Finley In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator J Endod 19 1993 545 548
-
(1993)
J Endod
, vol.19
, pp. 545-548
-
-
Mayeda, D.L.1
Simon, J.H.2
Aimar, D.F.3
Finley, K.4
-
15
-
-
0031600449
-
An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals
-
C.A. Dunlap, N.A. Remeikis, E.A. BeGole, and C.R. Rauschenberger An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals J Endod 24 1998 48 50
-
(1998)
J Endod
, vol.24
, pp. 48-50
-
-
Dunlap, C.A.1
Remeikis, N.A.2
Begole, E.A.3
Rauschenberger, C.R.4
-
16
-
-
33846128745
-
In vivo comparison of working length determination with two electronic apex locators
-
K.T. Wrbas, A.A. Ziegler, M.J. Altenburger, and J.F. Schirrmeister In vivo comparison of working length determination with two electronic apex locators Int Endod J 40 2007 133 138
-
(2007)
Int Endod J
, vol.40
, pp. 133-138
-
-
Wrbas, K.T.1
Ziegler, A.A.2
Altenburger, M.J.3
Schirrmeister, J.F.4
-
17
-
-
28944448625
-
Ex vivo comparison of two electronic apex locators with different scales and frequencies
-
D. Hor, S. Krusy, and T. Attin Ex vivo comparison of two electronic apex locators with different scales and frequencies Int Endod J 38 2005 855 859
-
(2005)
Int Endod J
, vol.38
, pp. 855-859
-
-
Hor, D.1
Krusy, S.2
Attin, T.3
-
18
-
-
78650179821
-
Root canal system preparation
-
K. Gulabivala, and C. Stock Root canal system preparation K. Gulabivala, C. Stock, R.T. Walker, Endodontics 3rd ed 2004 Elsevier, Mosby Edinburgh; New York 142 144
-
(2004)
Endodontics
, pp. 142-144
-
-
Gulabivala, K.1
Stock, C.2
-
19
-
-
0036484408
-
Accuracy of a new apex locator: An in vitro study
-
A.Y. Kaufman, S. Keila, and M. Yoshpe Accuracy of a new apex locator: an in vitro study Int Endod J 35 2002 186 192
-
(2002)
Int Endod J
, vol.35
, pp. 186-192
-
-
Kaufman, A.Y.1
Keila, S.2
Yoshpe, M.3
-
21
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
23
-
-
77049220185
-
Microscopic investigation of root apexes
-
Y. Kuttler Microscopic investigation of root apexes J Am Dent Assoc 50 1955 544 552
-
(1955)
J Am Dent Assoc
, vol.50
, pp. 544-552
-
-
Kuttler, Y.1
-
24
-
-
77950316069
-
Mixed dentition analysis using a multivariate approach
-
S.-H. Seo, H. An, S.-J. Lee, W.H. Lim, and B.-R. Kim Mixed dentition analysis using a multivariate approach Korean J Orthod 39 2009 112 119
-
(2009)
Korean J Orthod
, vol.39
, pp. 112-119
-
-
Seo, S.-H.1
An, H.2
Lee, S.-J.3
Lim, W.H.4
Kim, B.-R.5
|