메뉴 건너뛰기




Volumn 122, Issue 22, 2010, Pages 2234-2235

Editorial: Shedding light on bioabsorbable stent struts seen by optical coherence tomography in the ABSORB trial

Author keywords

animal model; biodegradable polymer; drug eluting stents; Editorials; optical coherence tomography

Indexed keywords

EDITORIAL; HEART CATHETERIZATION; HEART MUSCLE REVASCULARIZATION; OPTICAL COHERENCE TOMOGRAPHY; POLARIZATION; PRIORITY JOURNAL; STENT; ANIMAL; ANIMAL MODEL; BIODEGRADABLE IMPLANT; CORONARY ARTERY DISEASE; HUMAN; NOTE; SWINE; TIME;

EID: 78650178341     PISSN: 00097322     EISSN: 15244539     Source Type: Journal    
DOI: 10.1161/CIRCULATIONAHA.110.980730     Document Type: Editorial
Times cited : (8)

References (13)
  • 1
    • 0035960591 scopus 로고    scopus 로고
    • Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: Comparison with intravascular Ultrasound
    • Jang IK, Tearney G, Bouma B. Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: comparison with intravascular ultrasound. Circulation. 2001;104:2754. (Pubitemid 33108146)
    • (2001) Circulation , vol.104 , Issue.22 , pp. 2754
    • Jang, I.-K.1    Tearney, G.2    Bouma, B.3
  • 2
    • 35148829522 scopus 로고    scopus 로고
    • Coronary bioabsorbable magnesium stent: 15-Month intravascular ultrasound and optical coherence tomography findings
    • DOI 10.1093/eurheartj/ehm119
    • Barlis P, Tanigawa J, Di Mario C. Coronary bioabsorbable magnesium stent: 15-month intravascular ultrasound and optical coherence tomography findings. Eur Heart J. 2007;28:2319. (Pubitemid 47537770)
    • (2007) European Heart Journal , vol.28 , Issue.19 , pp. 2319
    • Barlis, P.1    Tanigawa, J.2    Di Mario, C.3
  • 3
    • 36349007769 scopus 로고    scopus 로고
    • Optical coherence tomographic imaging of a bioabsorbable magnesium stent lost in a porcine coronary artery
    • DOI 10.1016/j.carrev.2007.09.002, PII S155383890700303X
    • Pinto Slottow TL, Pakala R, Lovec RJ, Tio FO, Waksman R. Optical coherence tomographic imaging of a bioabsorbable magnesium stent lost in a porcine coronary artery. Cardiovasc Revasc Med. 2007;8:293-294. (Pubitemid 350161454)
    • (2007) Cardiovascular Revascularization Medicine , vol.8 , Issue.4 , pp. 293-294
    • Pinto Slottow, T.L.1    Pakala, R.2    Lovec, R.J.3    Tio, F.O.4    Waksman, R.5
  • 4
    • 35349018576 scopus 로고    scopus 로고
    • Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: Insights from the ABSORB and SPIRIT trials
    • DOI 10.1002/ccd.21136
    • Tanimoto S, Serruys PW, Thuesen L, Dudek D, de Bruyne B, Chevalier B, Ormiston JA. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials. Catheter Cardiovasc Interv. 2007;70:515-523. (Pubitemid 47597022)
    • (2007) Catheterization and Cardiovascular Interventions , vol.70 , Issue.4 , pp. 515-523
    • Tanimoto, S.1    Serruys, P.W.2    Thuesen, L.3    Dudek, D.4    De Bruyne, B.5    Chevalier, B.6    Ormiston, J.A.7
  • 5
    • 40649083620 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): A prospective open-label trial
    • DOI 10.1016/S0140-6736(08)60415-8, PII S0140673608604158
    • Ormiston JA, Serruys PW, Regar E, Dudek D, Thuesen L, Webster MW, Onuma Y, Garcia-Garcia HM, McGreevy R, Veldhof S. A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial. Lancet. 2008;371:899-907. (Pubitemid 351384734)
    • (2008) The Lancet , vol.371 , Issue.9616 , pp. 899-907
    • Ormiston, J.A.1    Serruys, P.W.2    Regar, E.3    Dudek, D.4    Thuesen, L.5    Webster, M.W.6    Onuma, Y.7    Garcia-Garcia, H.M.8    McGreevy, R.9    Veldhof, S.10
  • 6
    • 38849191742 scopus 로고    scopus 로고
    • Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery
    • DOI 10.1093/eurheartj/ehm365
    • Pinto Slottow TL, Pakala R, Waksman R. Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery. Eur Heart J. 2008;29:314. (Pubitemid 351197742)
    • (2008) European Heart Journal , vol.29 , Issue.3 , pp. 314
    • Pinto Slottow, T.L.1    Pakala, R.2    Waksman, R.3
  • 7
    • 53449099699 scopus 로고    scopus 로고
    • Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries
    • Slottow TL, Pakala R, Okabe T, Hellinga D, Lovec RJ, Tio FO, Bui AB, Waksman R. Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries. Cardiovasc Revasc Med. 2008;9:248-254.
    • (2008) Cardiovasc Revasc Med , vol.9 , pp. 248-254
    • Slottow, T.L.1    Pakala, R.2    Okabe, T.3    Hellinga, D.4    Lovec, R.J.5    Tio, F.O.6    Bui, A.B.7    Waksman, R.8
  • 10
    • 78650171486 scopus 로고    scopus 로고
    • Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: An attempt to decipher the human optical coherence tomography images in the ABSORB trial
    • Onuma Y, Serruys PW, Perkins LEL, Okamura T, Gonzalo N, Garcia-Garcia HM, Regar E, Kamberi M, Powers JC, Rapoza R, van Beusekom H, van der Giessen W, Virmani R. Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: an attempt to decipher the human optical coherence tomography images in the ABSORB trial. Circulation. 2010; 122:2288-2300.
    • (2010) Circulation , vol.122 , pp. 2288-2300
    • Onuma, Y.1    Serruys, P.W.2    Lel, P.3    Okamura, T.4    Gonzalo, N.5    Garcia-Garcia, H.M.6    Regar, E.7    Kamberi, M.8    Powers, J.C.9    Rapoza, R.10    Van Beusekom, H.11    Van Der Giessen, W.12    Virmani, R.13
  • 13
    • 34250352736 scopus 로고    scopus 로고
    • Polarization-sensitive optical coherence tomography for imaging human atherosclerosis
    • DOI 10.1364/AO.46.002520
    • Kuo WC, Chou NK, Chou C, Lai CM, Huang HJ, Wang SS, Shyu JJ. Polarization-sensitive optical coherence tomography for imaging human atherosclerosis. Appl Opt. 2007;46:2520-2527. (Pubitemid 46918396)
    • (2007) Applied Optics , vol.46 , Issue.13 , pp. 2520-2527
    • Kuo, W.-C.1    Chou, N.-K.2    Chou, C.3    Lai, C.-M.4    Huang, H.-J.5    Wang, S.-S.6    Shyu, J.-J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.