메뉴 건너뛰기




Volumn 80, Issue 2, 2011, Pages 169-174

Amperometric sensor for hydrogen peroxide based on direct electron transfer of spinach ferredoxin on Au electrode

Author keywords

Biosensor; Cyclic voltammetry; Ferredoxin; Hydrogen peroxide detection; Nanobiochip

Indexed keywords

11-MERCAPTOUNDECANOIC ACID; AG/AGCL; AMPEROMETRIC; AU ELECTRODES; DIRECT ELECTRON TRANSFER; ELECTROCHEMICAL BEHAVIORS; ELECTROCHEMICAL EXPERIMENTS; ELECTRON TRANSFER; ELECTRON-TRANSFER RATE CONSTANTS; FERREDOXIN; FILM FABRICATION; INTERFACIAL PROPERTY; IRON ATOMS; METAL CENTERS; MODIFIED ELECTRODES; NANOBIOCHIP; ONE-ELECTRON REDUCTIONS; REDOX COUPLE; REDOX PEAKS; REDUCTION POTENTIAL; SENSOR CALIBRATION; TRIS-HCL BUFFER SOLUTION;

EID: 78650172148     PISSN: 15675394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2010.08.002     Document Type: Article
Times cited : (30)

References (37)
  • 1
    • 34547643175 scopus 로고    scopus 로고
    • Direct electron transfer reaction of ascorbate oxidase immobilized by a self-assembled monolayer and polymer membrane combined system
    • Murata K., Nakamura N., Ohno H. Direct electron transfer reaction of ascorbate oxidase immobilized by a self-assembled monolayer and polymer membrane combined system. Electroanalysis 2007, 19:530-534.
    • (2007) Electroanalysis , vol.19 , pp. 530-534
    • Murata, K.1    Nakamura, N.2    Ohno, H.3
  • 2
    • 33747341598 scopus 로고    scopus 로고
    • Electrochemical characterization and application of azurin-modified gold electrodes for detection of superoxide
    • Shleev S., Wetterö J., Magnusson K., Ruzgas T. Electrochemical characterization and application of azurin-modified gold electrodes for detection of superoxide. Biosens. Bioelectron. 2006, 22:213-219.
    • (2006) Biosens. Bioelectron. , vol.22 , pp. 213-219
    • Shleev, S.1    Wetterö, J.2    Magnusson, K.3    Ruzgas, T.4
  • 3
    • 0030045725 scopus 로고    scopus 로고
    • Amperometric determination of hydrogen peroxide by direct and catalytic reduction at a copper electrode
    • Somasundrum M., Kirtikara K., Tanticharoen M. Amperometric determination of hydrogen peroxide by direct and catalytic reduction at a copper electrode. Anal. Chim. Acta 1996, 319:59-70.
    • (1996) Anal. Chim. Acta , vol.319 , pp. 59-70
    • Somasundrum, M.1    Kirtikara, K.2    Tanticharoen, M.3
  • 4
    • 0037077659 scopus 로고    scopus 로고
    • Direct wiring of cytochrome c's heme unit to an electrode: electrochemical studies
    • Wei J., Liu H., Dick A.R., Yamamoto H., He Y., Waldeck D.H. Direct wiring of cytochrome c's heme unit to an electrode: electrochemical studies. J. Am. Chem. Soc. 2002, 124:9591-9599.
    • (2002) J. Am. Chem. Soc. , vol.124 , pp. 9591-9599
    • Wei, J.1    Liu, H.2    Dick, A.R.3    Yamamoto, H.4    He, Y.5    Waldeck, D.H.6
  • 5
    • 33847370662 scopus 로고    scopus 로고
    • A novel wireless glucose sensor employing direct electron transfer principle based enzyme fuel cell
    • Kakehi N., Yamazaki T., Tsugawa W., Sode K. A novel wireless glucose sensor employing direct electron transfer principle based enzyme fuel cell. Biosens. Bioelectron. 2007, 22:2250-2255.
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 2250-2255
    • Kakehi, N.1    Yamazaki, T.2    Tsugawa, W.3    Sode, K.4
  • 6
    • 0030944115 scopus 로고    scopus 로고
    • Assembly of functionalized monolayers of redox proteins on electrode surface: novel bioelectronic and optobioelectronic systems
    • Willner I., Katz E., Willner B., Blonder R., Heleg-Shabtai V., Buckmann A.F. Assembly of functionalized monolayers of redox proteins on electrode surface: novel bioelectronic and optobioelectronic systems. Biosens. bioelectron. 1997, 12:337-356.
    • (1997) Biosens. bioelectron. , vol.12 , pp. 337-356
    • Willner, I.1    Katz, E.2    Willner, B.3    Blonder, R.4    Heleg-Shabtai, V.5    Buckmann, A.F.6
  • 7
    • 0035065346 scopus 로고    scopus 로고
    • Hydrogen peroxide biosensors based on direct electron transfer from plant peroxidases immobilized on self-assembled thiol-monolayer modified gold electrodes
    • Gaspar S., Zimmermann H., Gazaryan I., Csöregi E., Schuhmann W. Hydrogen peroxide biosensors based on direct electron transfer from plant peroxidases immobilized on self-assembled thiol-monolayer modified gold electrodes. Electroanalysis 2001, 13:284-288.
    • (2001) Electroanalysis , vol.13 , pp. 284-288
    • Gaspar, S.1    Zimmermann, H.2    Gazaryan, I.3    Csöregi, E.4    Schuhmann, W.5
  • 8
    • 0032920461 scopus 로고    scopus 로고
    • Biosensor for phenol based on the direct electron transfer blocking of peroxidase immobilising on silica-titanium
    • Rosatto S.S., Kubota L.T., Neto G.de.O. Biosensor for phenol based on the direct electron transfer blocking of peroxidase immobilising on silica-titanium. Anal. Chem. Acta 1999, 390:65-72.
    • (1999) Anal. Chem. Acta , vol.390 , pp. 65-72
    • Rosatto, S.S.1    Kubota, L.T.2    Neto, G.3
  • 9
    • 33846884403 scopus 로고    scopus 로고
    • Diazonium-functionalized horseradish peroxidase immobilized via addressable electrodeposition: direct electron transfer and electrochemical detection
    • Polsky R., Harper J.C., Dirk S.M., Arango D.C., Wheeler D.R., Brozik S.M. Diazonium-functionalized horseradish peroxidase immobilized via addressable electrodeposition: direct electron transfer and electrochemical detection. Langmuir 2007, 23:364-366.
    • (2007) Langmuir , vol.23 , pp. 364-366
    • Polsky, R.1    Harper, J.C.2    Dirk, S.M.3    Arango, D.C.4    Wheeler, D.R.5    Brozik, S.M.6
  • 10
    • 58149147452 scopus 로고    scopus 로고
    • Ultra-sensitive immunosensor for β-amyloid (1-42) using scanning tunneling microscopy-based electrical detection
    • Kang D., Lee J., Oh B., Choi J. Ultra-sensitive immunosensor for β-amyloid (1-42) using scanning tunneling microscopy-based electrical detection. Biosens. Bioelectron. 2009, 24:1431-1436.
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 1431-1436
    • Kang, D.1    Lee, J.2    Oh, B.3    Choi, J.4
  • 11
    • 33750360843 scopus 로고    scopus 로고
    • Application of complement 1q for the site-selective recognition of immune complex in protein chip
    • Choi J.-W., Lee W., Oh B., Lee H., Lee D. Application of complement 1q for the site-selective recognition of immune complex in protein chip. Biosens. Bioelectron. 2006, 22:764-767.
    • (2006) Biosens. Bioelectron. , vol.22 , pp. 764-767
    • Choi, J.-W.1    Lee, W.2    Oh, B.3    Lee, H.4    Lee, D.5
  • 12
    • 15944397554 scopus 로고    scopus 로고
    • Cell immobilization using self-assembled synthetic oligopeptide and its application to biological toxicity detection using surface plasmon resonance
    • Choi J.-W., Park K., Lee D., Lee W., Lee W.H. Cell immobilization using self-assembled synthetic oligopeptide and its application to biological toxicity detection using surface plasmon resonance. Biosens. Bioelectron. 2005, 20:2300-2305.
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 2300-2305
    • Choi, J.-W.1    Park, K.2    Lee, D.3    Lee, W.4    Lee, W.H.5
  • 13
    • 70350225817 scopus 로고    scopus 로고
    • The fabrication of protein chip based on surface plasmon resonance for detection of pathogens
    • Lee J.-H., Kang D.-Y., Lee T., Kim S.-U., Oh B.-K., Choi J.-W. The fabrication of protein chip based on surface plasmon resonance for detection of pathogens. J. Nanosci. Nanotechnol. 2009, 9:7155-7160.
    • (2009) J. Nanosci. Nanotechnol. , vol.9 , pp. 7155-7160
    • Lee, J.-H.1    Kang, D.-Y.2    Lee, T.3    Kim, S.-U.4    Oh, B.-K.5    Choi, J.-W.6
  • 14
    • 76649138299 scopus 로고    scopus 로고
    • Multilevel biomemory device consisting of recombinant azurin/cytochrome c
    • Lee T., Kim S.-U., Min J., Choi J.-W. Multilevel biomemory device consisting of recombinant azurin/cytochrome c. Adv. Mater. 2010, 22:510-514.
    • (2010) Adv. Mater. , vol.22 , pp. 510-514
    • Lee, T.1    Kim, S.-U.2    Min, J.3    Choi, J.-W.4
  • 15
    • 54549097592 scopus 로고    scopus 로고
    • The fabrication of cell chips for use as biosensors
    • Yea C.H., Min J., Choi J.W. The fabrication of cell chips for use as biosensors. BioChip J. 2007, 4:219-227.
    • (2007) BioChip J. , vol.4 , pp. 219-227
    • Yea, C.H.1    Min, J.2    Choi, J.W.3
  • 17
    • 6344285767 scopus 로고    scopus 로고
    • A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode
    • Zhang J., Oyama M. A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode. Electrochim. Acta 2004, 50:85-90.
    • (2004) Electrochim. Acta , vol.50 , pp. 85-90
    • Zhang, J.1    Oyama, M.2
  • 18
    • 1342306786 scopus 로고    scopus 로고
    • Immobilization of hemoglobin on zirconium dioxide nanoparticles for preparation of a novel hydrogen peroxide biosensor
    • Liu S., Dai Z., Chen H., Ju H. Immobilization of hemoglobin on zirconium dioxide nanoparticles for preparation of a novel hydrogen peroxide biosensor. Biosens. Bioelectron. 2004, 19:963-969.
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 963-969
    • Liu, S.1    Dai, Z.2    Chen, H.3    Ju, H.4
  • 19
    • 0036883541 scopus 로고    scopus 로고
    • Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode
    • Razola S.S., Ruiz B.L., Diez N.M., Mark H.B., Kauffmann J. Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode. Biosens. Bioelectron. 2002, 17:921-928.
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 921-928
    • Razola, S.S.1    Ruiz, B.L.2    Diez, N.M.3    Mark, H.B.4    Kauffmann, J.5
  • 20
    • 0033947948 scopus 로고    scopus 로고
    • Amperometric biosensors for sensing of hydrogen peroxide based on electron transfer between horseradish peroxidase and ferrocene as a mediator
    • Nakabayashi Y., Yoshikawa H. Amperometric biosensors for sensing of hydrogen peroxide based on electron transfer between horseradish peroxidase and ferrocene as a mediator. Anal. Sci. 2000, 16:609-613.
    • (2000) Anal. Sci. , vol.16 , pp. 609-613
    • Nakabayashi, Y.1    Yoshikawa, H.2
  • 21
    • 0030363580 scopus 로고    scopus 로고
    • Poly(o-aminophenol)-modified bienzyme carbon paste electrode for the detection of uric acid
    • Miland E., Ordieres A.J.M., Blanco P.T., Smyth M.R., Fágáin C.O. Poly(o-aminophenol)-modified bienzyme carbon paste electrode for the detection of uric acid. Talanta 1996, 43:785-796.
    • (1996) Talanta , vol.43 , pp. 785-796
    • Miland, E.1    Ordieres, A.J.M.2    Blanco, P.T.3    Smyth, M.R.4    Fágáin, C.O.5
  • 23
    • 0035861311 scopus 로고    scopus 로고
    • Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid-cysteamine-modified gold electrode
    • Gu H., Yu A., Chen H. Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid-cysteamine-modified gold electrode. J. Electroanal. Chem. 2001, 516:119-126.
    • (2001) J. Electroanal. Chem. , vol.516 , pp. 119-126
    • Gu, H.1    Yu, A.2    Chen, H.3
  • 24
    • 22044452968 scopus 로고    scopus 로고
    • Attachment of gold nanoparticles to glassy carbon electrode and its application for the direct electrochemistry and electrocatalytic behavior of hemoglobin
    • Zhang L., Jiang X., Wang E., Dong S. Attachment of gold nanoparticles to glassy carbon electrode and its application for the direct electrochemistry and electrocatalytic behavior of hemoglobin. Biosens. Bioelectron. 2005, 21:337-345.
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 337-345
    • Zhang, L.1    Jiang, X.2    Wang, E.3    Dong, S.4
  • 25
    • 2342616755 scopus 로고    scopus 로고
    • 2 biosensor based on the enzyme-like activity of myoglobin on multi-walled carbon nanotubes
    • 2 biosensor based on the enzyme-like activity of myoglobin on multi-walled carbon nanotubes. Anal. Biochem. 2004, 329:160-161.
    • (2004) Anal. Biochem. , vol.329 , pp. 160-161
    • Zhao, G.-C.1    Zhang, L.2    Wei, X.3
  • 27
    • 54549096964 scopus 로고    scopus 로고
    • A new enzyme immobilization technique based on thionine-bovine serum albumin conjugate and gold colloidal nanoparticles for reagentless amperometric biosensor applications
    • Chen S., Yuan R., Chai Y., Li N. A new enzyme immobilization technique based on thionine-bovine serum albumin conjugate and gold colloidal nanoparticles for reagentless amperometric biosensor applications. Electroanalysis 2008, 20:418-425.
    • (2008) Electroanalysis , vol.20 , pp. 418-425
    • Chen, S.1    Yuan, R.2    Chai, Y.3    Li, N.4
  • 28
    • 0014429438 scopus 로고
    • Spinach ferredoxin: amino acid composition and terminal seqences
    • Matsubara H., Sasaki R.M., Chain R.K. Spinach ferredoxin: amino acid composition and terminal seqences. J. Biol. Chem. 1968, 243:1725-1731.
    • (1968) J. Biol. Chem. , vol.243 , pp. 1725-1731
    • Matsubara, H.1    Sasaki, R.M.2    Chain, R.K.3
  • 29
    • 0015038868 scopus 로고
    • Mossbauer effect in scenedesmus and spinach feredoxins: the mechanism of electron transfer in plant-type iron-sulfur proteins
    • Rao K.K., Cammack R., Hall D.O., Johnson C.E. Mossbauer effect in scenedesmus and spinach feredoxins: the mechanism of electron transfer in plant-type iron-sulfur proteins. Biochem. J. 1971, 122:257-265.
    • (1971) Biochem. J. , vol.122 , pp. 257-265
    • Rao, K.K.1    Cammack, R.2    Hall, D.O.3    Johnson, C.E.4
  • 30
    • 49049115593 scopus 로고    scopus 로고
    • Direct electrochemistry of redox enzymes as a tool for mechanistic studies
    • Leger C., Bertrand P. Direct electrochemistry of redox enzymes as a tool for mechanistic studies. Chem. Rev. 2008, 108:2379-2438.
    • (2008) Chem. Rev. , vol.108 , pp. 2379-2438
    • Leger, C.1    Bertrand, P.2
  • 31
    • 0032717605 scopus 로고    scopus 로고
    • Direct electron transfer between heme-containing enzymes and electrodes as basis for third generation biosensors
    • Gorton L., Lindgren A., Larsson T., Munteanu F.D., Ruzgas T., Gazaryan I. Direct electron transfer between heme-containing enzymes and electrodes as basis for third generation biosensors. Anal. Chim. Acta 1999, 400:91-108.
    • (1999) Anal. Chim. Acta , vol.400 , pp. 91-108
    • Gorton, L.1    Lindgren, A.2    Larsson, T.3    Munteanu, F.D.4    Ruzgas, T.5    Gazaryan, I.6
  • 33
    • 0000777189 scopus 로고    scopus 로고
    • A scanning probe microscopy study of the physisorption and chemisorption of protein molecules onto carboxylate terminated self-assembled monolayers
    • Patel N., Davies M.C., Heaton R.J., Roberts C.J., Tendler S.J.B., Williams P.M. A scanning probe microscopy study of the physisorption and chemisorption of protein molecules onto carboxylate terminated self-assembled monolayers. Appl. Phys. A 1998, 66:S569-S574.
    • (1998) Appl. Phys. A , vol.66
    • Patel, N.1    Davies, M.C.2    Heaton, R.J.3    Roberts, C.J.4    Tendler, S.J.B.5    Williams, P.M.6
  • 34
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • Laviron E. General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems. J. Electroanal. Chem. 1979, 101:19-28.
    • (1979) J. Electroanal. Chem. , vol.101 , pp. 19-28
    • Laviron, E.1
  • 35
    • 0034897214 scopus 로고    scopus 로고
    • Amplification of antigen-antibody interactions based on biotin labeled protein-streptavidin network complex using impedance spectroscopy
    • Pei R., Cheng Z., Wang E., Yang X. Amplification of antigen-antibody interactions based on biotin labeled protein-streptavidin network complex using impedance spectroscopy. Biosens. Bioelectron. 2001, 16:355-361.
    • (2001) Biosens. Bioelectron. , vol.16 , pp. 355-361
    • Pei, R.1    Cheng, Z.2    Wang, E.3    Yang, X.4
  • 36
    • 0033878705 scopus 로고    scopus 로고
    • Electrochemical and in-situ ellipsometric investigation of the permeability and stability of layered polyelectrolyte films
    • Harris J.J., Bruening M.L. Electrochemical and in-situ ellipsometric investigation of the permeability and stability of layered polyelectrolyte films. Langmuir 2000, 16:2006-2013.
    • (2000) Langmuir , vol.16 , pp. 2006-2013
    • Harris, J.J.1    Bruening, M.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.