메뉴 건너뛰기




Volumn , Issue , 2010, Pages 3091-3095

Flexible control of DC-link voltage for doubly fed induction generator during grid voltage swell

Author keywords

Back to back converter; DC link voltage; Doubly fed induction generator; Grid voltage swell; Losses; Voltage control

Indexed keywords

BACK-TO-BACK CONVERTER; CONTROL STRATEGIES; CONVENTIONAL CONTROL; DC-LINK VOLTAGES; DOUBLY FED INDUCTION GENERATORS; DOUBLY-FED INDUCTION GENERATOR; FLEXIBLE CONTROL; GRID VOLTAGE; NORMAL OPERATIONS; POWER-LOSSES;

EID: 78650119902     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ECCE.2010.5618402     Document Type: Conference Paper
Times cited : (35)

References (14)
  • 1
    • 40449134843 scopus 로고    scopus 로고
    • Overview of different wind generator systems and their comparisons and their comparisons
    • June
    • H. Li, Z. Chen, "Overview of different wind generator systems and their comparisons and their comparisons, " IET Renewable Power Generation, vol. 2, no. 2, pp. 123-138, June 2008.
    • (2008) IET Renewable Power Generation , vol.2 , Issue.2 , pp. 123-138
    • Li, H.1    Chen, Z.2
  • 2
    • 40849141184 scopus 로고    scopus 로고
    • Wind turbines based on doubly fed induction generator under asymmetrical voltage dips
    • March
    • J. Lopez, E. Gubia, P. Sanchis, X. Roboam, and L. Marroyo, "Wind turbines based on doubly fed induction generator under asymmetrical voltage dips, " IEEE Trans. on Energy Conversion, vol. 23, pp. 321- 330, March 2008.
    • (2008) IEEE Trans. on Energy Conversion , vol.23 , pp. 321-330
    • Lopez, J.1    Gubia, E.2    Sanchis, P.3    Roboam, X.4    Marroyo, L.5
  • 3
    • 25144466008 scopus 로고    scopus 로고
    • Transient stability of DFIG wind turbines at an external short-circuit fault
    • August
    • T. Sun, Z. Chen, and F. Blaabjerg, "Transient stability of DFIG wind turbines at an external short-circuit fault, " Wind Energy, vol. 8, pp. 345-360, August 2005.
    • (2005) Wind Energy , vol.8 , pp. 345-360
    • Sun, T.1    Chen, Z.2    Blaabjerg, F.3
  • 4
    • 85008063672 scopus 로고    scopus 로고
    • Providing ride-through capability to a doubly fed induction generator under unbalanced voltage dips
    • July
    • D. Santos-Martin, J. L. Rodriguez-Amenedo, and S. Arnaltes, "Providing ride-through capability to a doubly fed induction generator under unbalanced voltage dips, " IEEE Trans. on Power Electronics, vol. 24, no. 7, pp. 1747-1757, July 2009.
    • (2009) IEEE Trans. on Power Electronics , vol.24 , Issue.7 , pp. 1747-1757
    • Santos-Martin, D.1    Rodriguez-Amenedo, J.L.2    Arnaltes, S.3
  • 5
    • 76649127421 scopus 로고    scopus 로고
    • Rotor voltage dynamics in the doubly fed induction generator during grid faults
    • Jan.
    • F. K. Lima, A. Luna, P. Rodriguez, E. H. Watanabe, and F. Blaabjerg, "Rotor voltage dynamics in the doubly fed induction generator during grid faults, " IEEE Trans. on Power Electronics, vol. 25, no. 1, pp. 118- 130, Jan. 2010.
    • (2010) IEEE Trans. on Power Electronics , vol.25 , Issue.1 , pp. 118-130
    • Lima, F.K.1    Luna, A.2    Rodriguez, P.3    Watanabe, E.H.4    Blaabjerg, F.5
  • 6
    • 25144444348 scopus 로고    scopus 로고
    • International comparison of requirements for connection of wind turbines to power systems
    • July
    • C. Jauch, J. Matevosyan, T. Ackermann, and S. Bolik, "International comparison of requirements for connection of wind turbines to power systems, " Wind Energy, vol. 8, no. 3, pp. 295-306, July 2005.
    • (2005) Wind Energy , vol.8 , Issue.3 , pp. 295-306
    • Jauch, C.1    Matevosyan, J.2    Ackermann, T.3    Bolik, S.4
  • 7
    • 44449131797 scopus 로고    scopus 로고
    • An improved control strategy of limiting the dc-Link voltage fluctuation for a doubly fed induction wind generator
    • May
    • J. Yao, H. Li, Y. Liao, and Z. Chen, "An improved control strategy of limiting the dc-Link voltage fluctuation for a doubly fed induction wind generator, " IEEE Trans. on Power Electronics, vol. 23, no. 3, pp. 1205- 1213, May 2008.
    • (2008) IEEE Trans. on Power Electronics , vol.23 , Issue.3 , pp. 1205-1213
    • Yao, J.1    Li, H.2    Liao, Y.3    Chen, Z.4
  • 8
    • 44449096034 scopus 로고    scopus 로고
    • A dc voltage monitoring and control method for three-phase grid-connected wind turbine inverters
    • May
    • Z. Wang, L. Chang, "A dc voltage monitoring and control method for three-phase grid-connected wind turbine inverters, " IEEE Trans. on Power Electronics, vol. 23, no. 3, pp. 1118-1125, May 2008.
    • (2008) IEEE Trans. on Power Electronics , vol.23 , Issue.3 , pp. 1118-1125
    • Wang, Z.1    Chang, L.2
  • 9
    • 50649116153 scopus 로고    scopus 로고
    • Modeling and control of grid-connected voltage-sourced converters under generalized unbalanced operation conditions
    • Sept.
    • J. Hu, Y. He, "Modeling and control of grid-connected voltage-sourced converters under generalized unbalanced operation conditions, " IEEE Trans. on Energy Conversion, vol. 23, no. 3, pp. 903-913, Sept. 2008.
    • (2008) IEEE Trans. on Energy Conversion , vol.23 , Issue.3 , pp. 903-913
    • Hu, J.1    He, Y.2
  • 10
    • 44449142859 scopus 로고    scopus 로고
    • Coordinated control of DFIG's rotor and grid side converters during network unbalance
    • May
    • L. Xu, "Coordinated control of DFIG's rotor and grid side converters during network unbalance, " IEEE Trans. on Power Electronics, vol. 23, no. 3, pp. 1041-1049, May 2008.
    • (2008) IEEE Trans. on Power Electronics , vol.23 , Issue.3 , pp. 1041-1049
    • Xu, L.1
  • 13
    • 0033705678 scopus 로고    scopus 로고
    • DC-bus voltage control of threephase AC/DC PWM converters using feedback linearization
    • May/June
    • D.-C. Lee, G. Lee, and K.-D. Lee, "DC-bus voltage control of threephase AC/DC PWM converters using feedback linearization, " IEEE Trans. on Industry Applications, vol. 36, no. 3, pp. 826-833, May/June 2000.
    • (2000) IEEE Trans. on Industry Applications , vol.36 , Issue.3 , pp. 826-833
    • Lee, D.-C.1    Lee, G.2    Lee, K.-D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.