Volumn 17, Issue 6, 2010, Pages 767-776

Comparison of second-generation stents for application in the superficial femoral artery: An in vitro evaluation focusing on stent design

Author keywords

Bending; Compression; Experimental study; Fatigue testing; Finite element analysis; Nitinol; Stent; Stent design; Stent fracture; Superficial femoral artery; Torsion

Indexed keywords

NITINOL;

EID: 78650114629     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/10-3069.1     Document Type: Article
Times cited : (43)

References (16)
  • 1
    • 0034878180 scopus 로고    scopus 로고
    • Randomized study to compare PTA alone versus PTA with Palmaz stent placement for femoropopliteal lesions
    • Grimm J, Müller-Hülsbeck S, Jahnke T, et al. Randomized study to compare PTA alone versus PTA with Palmaz stent placement for femoropopliteal lesions. J Vasc Interv Radiol. 2001;12:935-942.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 935-942
    • Grimm, J.1    Müller-Hülsbeck, S.2    Jahnke, T.3
  • 4
    • 0037126077 scopus 로고    scopus 로고
    • Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease: Six-month results
    • Duda SH, Pusich B, Richter G, et al. Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease: six-month results. Circulation. 2002;106:1505-1509.
    • (2002) Circulation , vol.106 , pp. 1505-1509
    • Duda, S.H.1    Pusich, B.2    Richter, G.3
  • 7
    • 77956639806 scopus 로고    scopus 로고
    • MISAGO 1: First-in-man clinical trial with Misago nitinol stent
    • Schulte KL, Müller-Hülsbeck S, Cao P, et al. MISAGO 1: first-in-man clinical trial with Misago nitinol stent. EuroIntervention. 2010;5:687-691.
    • (2010) EuroIntervention , vol.5 , pp. 687-691
    • Schulte, K.L.1    Müller-Hülsbeck, S.2    Cao, P.3
  • 9
    • 70350576544 scopus 로고    scopus 로고
    • Quantitative assessment of the conformational change in the femoropopliteal arterywith leg movement
    • Klein AJ, Chen SJ, Messenger JC, et al. Quantitative assessment of the conformational change in the femoropopliteal arterywith leg movement. Catheter Cardiovasc Interv. 2009;74:787-798.
    • (2009) Catheter Cardiovasc Interv , vol.74 , pp. 787-798
    • Klein, A.J.1    Chen, S.J.2    Messenger, J.C.3
  • 10
    • 33748146391 scopus 로고    scopus 로고
    • In vivo MR angiographic quantification of axial and twisting deformations of the superficial femoral artery resulting from maximum hip and knee flexion
    • Cheng CP, Wilson NM, Hallett RL, et al. In vivo MR angiographic quantification of axial and twisting deformations of the superficial femoral artery resulting from maximum hip and knee flexion. J Vasc Interv Radiol. 2006;17:979-987.
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 979-987
    • Cheng, C.P.1    Wilson, N.M.2    Hallett, R.L.3
  • 11
    • 74449085296 scopus 로고    scopus 로고
    • The effect of aging on deformations of the superficial femoral artery resulting from hip and knee flexion: Potential clinical implications
    • Cheng CP, Choi G, Herfkens RJ, et al. The effect of aging on deformations of the superficial femoral artery resulting from hip and knee flexion: potential clinical implications. J Vasc Interv Radiol. 2010;21:195-202.
    • (2010) J Vasc Interv Radiol , vol.21 , pp. 195-202
    • Cheng, C.P.1    Choi, G.2    Herfkens, R.J.3
  • 12
    • 66149141026 scopus 로고    scopus 로고
    • In vivo quantification of femoral-popliteal compression during isometric thigh contraction: Assessment using MR angiography
    • Brown R, Nguyen TD, Spincemaille P, et al. In vivo quantification of femoral-popliteal compression during isometric thigh contraction: assessment using MR angiography. J Magn Reson Imaging. 2009;29:1116-1124.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 1116-1124
    • Brown, R.1    Nguyen, T.D.2    Spincemaille, P.3
  • 14
    • 68549090697 scopus 로고    scopus 로고
    • Nitinol stent implantation in long superficial femoral artery lesions: 12-month results of the DURABILITY I study
    • Bosiers M, Torsello G, Gissler HM, et al. Nitinol stent implantation in long superficial femoral artery lesions: 12-month results of the DURABILITY I study. J Endovasc Ther. 2009;16:261-269.
    • (2009) J Endovasc Ther , vol.16 , pp. 261-269
    • Bosiers, M.1    Torsello, G.2    Gissler, H.M.3
  • 15
    • 47349088904 scopus 로고    scopus 로고
    • Fracture of self-expanding nitinol stents stressed in vitro under simulated intravascular conditions
    • Nikanorov A, Smouse HB, Osman K, et al. Fracture of self-expanding nitinol stents stressed in vitro under simulated intravascular conditions. Vasc Surg. 2008;48:435-340.
    • (2008) Vasc Surg , vol.48 , pp. 435-1340
    • Nikanorov, A.1    Smouse, H.B.2    Osman, K.3
  • 16
    • 35848945086 scopus 로고    scopus 로고
    • Standardized evaluation and reporting of stent fractures in clinical trials of noncoronary devices
    • DOI 10.1002/ccd.21240
    • Jaff M, Dake M, Pompa J, et al. Standardized evaluation and reporting of stent fractures in clinical trials of noncoronary devices. Catheter Cardiovasc Interv. 2007;70:460-462. (Pubitemid 350194998)
    • (2007) Catheterization and Cardiovascular Interventions , vol.70 , Issue.3 , pp. 460-462
    • Jaff, M.1    Dake, M.2    Pompa, J.3    Ansel, G.4    Yoder, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.