메뉴 건너뛰기




Volumn 71, Issue 6, 2010, Pages 403-410

Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch;Präzision eines instrumentellen Analyseverfahrens der Okklusion und ihrer resultierenden Kraftverteilung im Zahnbogen

Author keywords

Functional diagnostics; Functional therapy; Occlusal analysis; T Scan

Indexed keywords

ADULT; ARTICLE; COMPUTER ASSISTED DIAGNOSIS; DENTAL CARE; EQUIPMENT; EQUIPMENT DESIGN; EVALUATION; FEMALE; HUMAN; INSTRUMENTATION; MALE; MANOMETRY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TOOTH OCCLUSION;

EID: 78650083051     PISSN: 14345293     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00056-010-1023-7     Document Type: Article
Times cited : (131)

References (28)
  • 1
    • 0015400312 scopus 로고
    • The six keys to normal occlusion
    • 10.1016/S0002-9416(72)90268-0 4505873
    • L.F. Andrews 1972 The six keys to normal occlusion Am J Orthod 62 296 309 10.1016/S0002-9416(72)90268-0 4505873
    • (1972) Am J Orthod , vol.62 , pp. 296-309
    • Andrews, L.F.1
  • 2
    • 78650109307 scopus 로고
    • Über den artikulären Ausgleich und die Entlastungstherapie beim Knirsch- und Pressgebiss
    • 13241177
    • W. Balters 1955 Über den artikulären Ausgleich und die Entlastungstherapie beim Knirsch- und Pressgebiss Dtsch Zahnärztl Z 10 867 73 13241177
    • (1955) Dtsch Zahnärztl Z , vol.10 , pp. 867-73
    • Balters, W.1
  • 5
    • 41449104524 scopus 로고    scopus 로고
    • Fractures related to occlusal overload with single posterior implants: A clinical report
    • 10.1016/S0022-3913(08)00041-3 18395533
    • H.J. Conrad J.K. Schulte M.C. Vallee 2008 Fractures related to occlusal overload with single posterior implants: a clinical report J Prosthet Dent 99 251 6 10.1016/S0022-3913(08)00041-3 18395533
    • (2008) J Prosthet Dent , vol.99 , pp. 251-6
    • Conrad, H.J.1    Schulte, J.K.2    Vallee, M.C.3
  • 6
    • 0026749467 scopus 로고
    • Der Einsatz des T-Scan-Systems in der okklusalen Diagnostik
    • 1420658
    • A. Dees K. Kess P. Proff 1992 Der Einsatz des T-Scan-Systems in der okklusalen Diagnostik Dtsch Zahn Mund Kieferheilkd Zentralbl 80 145 51 1420658
    • (1992) Dtsch Zahn Mund Kieferheilkd Zentralbl , vol.80 , pp. 145-51
    • Dees, A.1    Kess, K.2    Proff, P.3
  • 7
    • 53149132450 scopus 로고    scopus 로고
    • Phenomenon of domination of the strongest contacts in centric occlusion
    • 18618031
    • A.D. Filtchev Y.S. Kalachev 2008 Phenomenon of domination of the strongest contacts in centric occlusion Quintessence Int 39 e99 106 18618031
    • (2008) Quintessence Int , vol.39 , pp. 99-106
    • Filtchev, A.D.1    Kalachev, Y.S.2
  • 8
    • 0022704898 scopus 로고
    • Reproducibility of occlusal marking techniques
    • 10.1016/0022-3913(86)90188-5 3457184
    • E. Gazit S. Fitzig M.A. Lieberman 1986 Reproducibility of occlusal marking techniques J Prosthet Dent 55 505 9 10.1016/0022-3913(86)90188-5 3457184
    • (1986) J Prosthet Dent , vol.55 , pp. 505-9
    • Gazit, E.1    Fitzig, S.2    Lieberman, M.A.3
  • 9
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
    • 10.1034/j.1600-0501.1996.070208.x 9002833
    • F. Isidor 1996 Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys Clin Oral Implants Res 7 143 52 10.1034/j.1600-0501.1996.070208.x 9002833
    • (1996) Clin Oral Implants Res , vol.7 , pp. 143-52
    • Isidor, F.1
  • 10
    • 0035469413 scopus 로고    scopus 로고
    • Current applications of computerized occlusal analysis in dental medicine
    • 12017798
    • R.B. Kerstein 2001 Current applications of computerized occlusal analysis in dental medicine Gen Dent 49 521 30 12017798
    • (2001) Gen Dent , vol.49 , pp. 521-30
    • Kerstein, R.B.1
  • 11
    • 54749110255 scopus 로고    scopus 로고
    • Articulating paper mark misconceptions and computerized occlusal analysis technology
    • 18686885
    • R.B. Kerstein 2008 Articulating paper mark misconceptions and computerized occlusal analysis technology Dent Implantol Update 19 41 6 18686885
    • (2008) Dent Implantol Update , vol.19 , pp. 41-6
    • Kerstein, R.B.1
  • 12
    • 53749104670 scopus 로고    scopus 로고
    • T-scan III applications in mixed arch and complete arch, implant-supported prosthodontics
    • 18700457
    • R.B. Kerstein 2008 T-scan III applications in mixed arch and complete arch, implant-supported prosthodontics Dent Implantol Update 19 49 53 18700457
    • (2008) Dent Implantol Update , vol.19 , pp. 49-53
    • Kerstein, R.B.1
  • 13
    • 0018276770 scopus 로고
    • Diagnostik vorzeitiger Kontakte
    • 279172
    • J. Komari 1978 Diagnostik vorzeitiger Kontakte ZWR 87 768 70 279172
    • (1978) ZWR , vol.87 , pp. 768-70
    • Komari, J.1
  • 14
    • 67349242497 scopus 로고    scopus 로고
    • Analysis of fracture and deformation modes in teeth subjected to occlusal loading
    • 10.1016/j.actbio.2009.02.001 19268644
    • B.R. Lawn J.J. Lee 2009 Analysis of fracture and deformation modes in teeth subjected to occlusal loading Acta Biomater 5 2213 21 10.1016/j.actbio. 2009.02.001 19268644
    • (2009) Acta Biomater , vol.5 , pp. 2213-21
    • Lawn, B.R.1    Lee, J.J.2
  • 15
    • 0020800998 scopus 로고
    • An evaluation of occlusal contact marking indicators: A descriptive, qualitative method
    • 6587420
    • P.L. Millstein 1983 An evaluation of occlusal contact marking indicators: a descriptive, qualitative method Quintessence Int Dent Dig 14 813 36 6587420
    • (1983) Quintessence Int Dent Dig , vol.14 , pp. 813-36
    • Millstein, P.L.1
  • 16
    • 33646820024 scopus 로고    scopus 로고
    • Chewing Patterns in Subjects with Normal Occlusion and With Malocclusions
    • DOI 10.1053/j.sodo.2006.01.007, PII S1073874606000089
    • P.A. Pröschel 2006 Chewing patterns in subjects with normal occlusion and with malocclusions Semin Orthod 12 138 49 10.1053/j.sodo.2006.01. 007 (Pubitemid 43758555)
    • (2006) Seminars in Orthodontics , vol.12 , Issue.2 , pp. 138-149
    • Proeschel, P.A.1
  • 17
    • 0026921680 scopus 로고
    • Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system
    • 10.1034/j.1600-0501.1992.030302.x 1290790
    • M. Quirynen I. Naert D. van Steenberghe 1992 Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system Clin Oral Implants Res 3 104 11 10.1034/j.1600-0501.1992.030302.x 1290790
    • (1992) Clin Oral Implants Res , vol.3 , pp. 104-11
    • Quirynen, M.1    Naert, I.2    Van Steenberghe, D.3
  • 18
    • 0029303274 scopus 로고
    • Bending overload and implant fracture: A retrospective clinical analysis
    • 7615329
    • B. Rangert P.H. Krogh B. Langer 1995 Bending overload and implant fracture: a retrospective clinical analysis Int J Oral Maxillofac Implants 10 326 34 7615329
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 326-34
    • Rangert, B.1    Krogh, P.H.2    Langer, B.3
  • 19
    • 0024609526 scopus 로고
    • Das Zeichnungsverhalten von Okklusionindikatoren. I. Einfluss der Indikatorstärke, des Druckes und der Oberflächenmorphologie
    • 2598875
    • T. Reiber K. Fuhr H. Hartmann 1989 Das Zeichnungsverhalten von Okklusionindikatoren. I. Einfluss der Indikatorstärke, des Druckes und der Oberflächenmorphologie Dtsch Zahnärztl Z 44 90 3 2598875
    • (1989) Dtsch Zahnärztl Z , vol.44 , pp. 90-3
    • Reiber, T.1    Fuhr, K.2    Hartmann, H.3
  • 20
    • 0024721985 scopus 로고
    • Das Zeichnungsverhalten von Okklusionsindikatoren. Einfluss des Oberflächenmaterials und der Oberflächenrauhigkeit
    • 2639556
    • T. Reiber K. Fuhr H. Hartmann 1989 Das Zeichnungsverhalten von Okklusionsindikatoren. Einfluss des Oberflächenmaterials und der Oberflächenrauhigkeit ZWR 98 756 2639556
    • (1989) ZWR , vol.98 , pp. 756
    • Reiber, T.1    Fuhr, K.2    Hartmann, H.3
  • 21
    • 0026422087 scopus 로고
    • Beurteilung des T-SCAN-Systems zur Registierung der okklusalen Kontaktverhältnisse
    • 1872056
    • W. Scholz H. Pancherz R. Reichel 1991 Beurteilung des T-SCAN-Systems zur Registierung der okklusalen Kontaktverhältnisse Zahnärztl Prax 42 6 9 1872056
    • (1991) Zahnärztl Prax , vol.42 , pp. 6-9
    • Scholz, W.1    Pancherz, H.2    Reichel, R.3
  • 22
    • 0025459473 scopus 로고
    • Messeigenschaften eines Systems zur digitalen Okklusionsdiagnostik
    • 2269157
    • J. Setz J. Geis-Gerstorfer 1990 Messeigenschaften eines Systems zur digitalen Okklusionsdiagnostik Dtsch Zahnärztl Z 45 S65 6 2269157
    • (1990) Dtsch Zahnärztl Z , vol.45 , pp. 65-6
    • Setz, J.1    Geis-Gerstorfer, J.2
  • 23
    • 78650122144 scopus 로고    scopus 로고
    • Comparison of the Greifswald Digital Analyzing System with the T-Scan III with respect to clinical reproducibility for displaying occlusal contacts
    • K. Stern B. Korda 2010 Comparison of the Greifswald Digital Analyzing System with the T-Scan III with respect to clinical reproducibility for displaying occlusal contacts J CranioMand Func 2 107 19
    • (2010) J CranioMand Func , vol.2 , pp. 107-19
    • Stern, K.1    Korda, B.2
  • 24
    • 0036561465 scopus 로고    scopus 로고
    • Changes in occlusal force and occlusal contact area after active orthodontic treatment: A pilot study using pressure-sensitive sheets
    • DOI 10.1046/j.1365-2842.2002.00849.x
    • M.H. Sultana K. Yamada K. Hanada 2002 Changes in occlusal force and occlusal contact area after active orthodontic treatment: a pilot study using pressure-sensitive sheets J Oral Rehabil 29 484 91 10.1046/j.1365-2842.2002. 00849.x 12028498 (Pubitemid 41697891)
    • (2002) Journal of Oral Rehabilitation , vol.29 , Issue.5 , pp. 484-491
    • Sultana, M.H.1    Yamada, K.2    Hanada, K.3
  • 25
    • 40849118285 scopus 로고    scopus 로고
    • Peri-implant bone loss caused by occlusal overload: Repair of the peri-implant defect following correction of the traumatic occlusion. A case report
    • 18416428
    • G. Tawil 2008 Peri-implant bone loss caused by occlusal overload: repair of the peri-implant defect following correction of the traumatic occlusion. A case report Int J Oral Maxillofac Implants 23 153 7 18416428
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 153-7
    • Tawil, G.1
  • 26
    • 69149084700 scopus 로고    scopus 로고
    • Calibration of T-Scan sensors for recording bite forces in denture patients
    • 10.1111/j.1365-2842.2009.01978.x 19602099
    • G.S. Throckmorton J. Rasmussen R. Caloss 2009 Calibration of T-Scan sensors for recording bite forces in denture patients J Oral Rehabil 36 636 43 10.1111/j.1365-2842.2009.01978.x 19602099
    • (2009) J Oral Rehabil , vol.36 , pp. 636-43
    • Throckmorton, G.S.1    Rasmussen, J.2    Caloss, R.3
  • 27
    • 0025703538 scopus 로고
    • T-Scan - Möglichkeiten und Grenzen eines neuen okklusionsdiagnostischen Verfahrens
    • 2238913
    • H. Tschernitschek G. Handel H. Gunay 1990 T-Scan - Möglichkeiten und Grenzen eines neuen okklusionsdiagnostischen Verfahrens Zahnärztl Prax 41 54 6 2238913
    • (1990) Zahnärztl Prax , vol.41 , pp. 54-6
    • Tschernitschek, H.1    Handel, G.2    Gunay, H.3
  • 28
    • 0034160828 scopus 로고    scopus 로고
    • Occlusal contact force and stress analysis of molars with vertical root split
    • 11780488
    • Y. Zeng J. Wang S. [. Zhou 2000 Occlusal contact force and stress analysis of molars with vertical root split Zhonghua Kou Qiang Yi Xue Za Zhi 35 142 3 11780488
    • (2000) Zhonghua Kou Qiang Yi Xue Za Zhi , vol.35 , pp. 142-3
    • Zeng, Y.1    Wang, J.2    Zhou, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.