메뉴 건너뛰기




Volumn 37, Issue 12, 2010, Pages 6466-6479

Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems

Author keywords

commissioning; FMEA; MLC tracking; quality assurance

Indexed keywords

BIOMEDICAL ENGINEERING; FAILURE (MECHANICAL); FAILURE MODES; QUALITY ASSURANCE; QUALITY CONTROL; SOFTWARE TESTING; TRACKING (POSITION); TUMORS;

EID: 78650081291     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3517837     Document Type: Article
Times cited : (67)

References (33)
  • 1
    • 42949109604 scopus 로고    scopus 로고
    • Management of three-dimensional intrafraction motion through real-time DMLC tracking
    • DOI 10.1118/1.2905355
    • A. Sawant, R. Venkat, V. Srivastava, D. Carlson, S. Povzner, H. Cattell, and P. Keall, " Management of three-dimensional intrafraction motion through real-time DMLC tracking.," Med. Phys. MPHYA6 0094-2405 35, 2050-2061 (2008). 10.1118/1.2905355 (Pubitemid 351614820)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 2050-2061
    • Sawant, A.1    Venkat, R.2    Srivastava, V.3    Carlson, D.4    Povzner, S.5    Cattell, H.6    Keall, P.7
  • 2
    • 60549112021 scopus 로고    scopus 로고
    • DMLC motion tracking of moving targets for intensity modulated arc therapy treatment: A feasibility study
    • ACTOEL 0284-186X. 10.1080/02841860802266722
    • J. Zimmerman, S. Korreman, G. Persson, H. Cattell, M. Svatos, A. Sawant, R. Venkat, D. Carlson, and P. Keall, " DMLC motion tracking of moving targets for intensity modulated arc therapy treatment: A feasibility study.," Acta Oncol. ACTOEL 0284-186X 48, 245-250 (2009). 10.1080/02841860802266722
    • (2009) Acta Oncol. , vol.48 , pp. 245-250
    • Zimmerman, J.1    Korreman, S.2    Persson, G.3    Cattell, H.4    Svatos, M.5    Sawant, A.6    Venkat, R.7    Carlson, D.8    Keall, P.9
  • 3
    • 65449175240 scopus 로고    scopus 로고
    • Toward submillimeter accuracy in the management of intrafraction motion: The integration of real-time internal position monitoring and multileaf collimator target tracking
    • IOBPD3 0360-3016. 10.1016/j.ijrob2008.12.057
    • A. Sawant, R. L. Smith, R. B. Venkat, L. Santanam, B. Cho, P. Poulsen, H. Cattell, L. J. Newell, P. Parikh, and P. J. Keall, " Toward submillimeter accuracy in the management of intrafraction motion: The integration of real-time internal position monitoring and multileaf collimator target tracking.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 74, 575-582 (2009). 10.1016/j.ijrobp.2008.12.057
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.74 , pp. 575-582
    • Sawant, A.1    Smith, R.L.2    Venkat, R.B.3    Santanam, L.4    Cho, B.5    Poulsen, P.6    Cattell, H.7    Newell, L.J.8    Parikh, P.9    Keall, P.J.10
  • 4
    • 67049109075 scopus 로고    scopus 로고
    • Integration of real-time internal electromagnetic position monitoring coupled with dynamic multileaf collimator tracking: An intensity-modulated radiation therapy feasibility study
    • IOBPD3 0360-3016. 10.1016/j.ijrob2009.01.031
    • R. L. Smith, A. Sawant, L. Santanam, R. B. Venkat, L. J. Newell, B. C. Cho, P. Poulsen, H. Catell, P. J. Keall, and P. J. Parikh, " Integration of real-time internal electromagnetic position monitoring coupled with dynamic multileaf collimator tracking: An intensity-modulated radiation therapy feasibility study.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 74, 868-875 (2009). 10.1016/j.ijrobp.2009.01.031
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.74 , pp. 868-875
    • Smith, R.L.1    Sawant, A.2    Santanam, L.3    Venkat, R.B.4    Newell, L.J.5    Cho, B.C.6    Poulsen, P.7    Catell, H.8    Keall, P.J.9    Parikh, P.J.10
  • 5
    • 67049086549 scopus 로고    scopus 로고
    • First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking
    • IOBPD3 0360-3016. 10.1016/j.ijrob2009.02.012
    • B. Cho, P. R. Poulsen, A. Sloutsky, A. Sawant, and P. J. Keall, " First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 74, 859-867 (2009). 10.1016/j.ijrobp.2009.02.012
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.74 , pp. 859-867
    • Cho, B.1    Poulsen, P.R.2    Sloutsky, A.3    Sawant, A.4    Keall, P.J.5
  • 6
    • 75749118592 scopus 로고    scopus 로고
    • Real-time tumor tracking: Automatic compensation of target motion using ythe Siemens 160 MLC
    • MPHYA6 0094-2405 ().
    • U. Oelfke, M. Tacke, A. Kraus, and S. Nill, " Real-time tumor tracking: Automatic compensation of target motion using ythe Siemens 160 MLC.," Med. Phys. MPHYA6 0094-2405 37 (2), 753-761 (2009).
    • (2009) Med. Phys. , vol.37 , Issue.2 , pp. 753-761
    • Oelfke, U.1    Tacke, M.2    Kraus, A.3    Nill, S.4
  • 8
    • 0036580468 scopus 로고    scopus 로고
    • Using health care failure mode and effect analysis: The VA National Center for patient safety's prospective risk analysis system
    • ZZZZZZ ().
    • J. DeRosier, E. Stalhandske, J. P. Bagian, and T. Nudell, " Using health care failure mode and effect analysis: The VA National Center for patient safety's prospective risk analysis system.," Jt. Common. J. Qual. Improv. ZZZZZZ 27 (5), 248-267 (2002).
    • (2002) Jt. Common. J. Qual. Improv. , vol.27 , Issue.5 , pp. 248-267
    • Derosier, J.1    Stalhandske, E.2    Bagian, J.P.3    Nudell, T.4
  • 9
    • 0141832682 scopus 로고    scopus 로고
    • Using failure mode and effects analysis to improve patient safety
    • ZZZZZZ 0001-2092. 10.1016/S0001-2092(06)61343-4
    • P. L. Spath, " Using failure mode and effects analysis to improve patient safety.," AORN J. ZZZZZZ 0001-2092 78, 15-37 (2003). 10.1016/S0001-2092(06)61343-4
    • (2003) AORN J. , vol.78 , pp. 15-37
    • Spath, P.L.1
  • 10
    • 16544393971 scopus 로고    scopus 로고
    • Failure mode and effects analysis. A hands-on guide for healthcare facilities
    • ZZZZZZ 0046-7022.
    • " Failure mode and effects analysis. A hands-on guide for healthcare facilities.," Health Devices ZZZZZZ 0046-7022 33, 233-243 (2004).
    • (2004) Health Devices , vol.33 , pp. 233-243
  • 13
    • 41749099277 scopus 로고    scopus 로고
    • Tools for developing a quality management program: Proactive tools (process mapping, value stream mapping, fault tree analysis, and failure mode and effects analysis)
    • IOBPD3 0360-3016. 10.1016/j.ijrob2007.07.2385
    • F. Rath, " Tools for developing a quality management program: Proactive tools (process mapping, value stream mapping, fault tree analysis, and failure mode and effects analysis).," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 71, S187-S190 (2008). 10.1016/j.ijrobp.2007.07.2385
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.71
    • Rath, F.1
  • 15
    • 76849090485 scopus 로고    scopus 로고
    • Kernel density estimation-based real-time prediction for respiratory motion
    • PHMBA7 0031-9155. 10.1088/0031-9155/55/5/004
    • D. Ruan, " Kernel density estimation-based real-time prediction for respiratory motion.," Phys. Med. Biol. PHMBA7 0031-9155 55, 1311-1326 (2010). 10.1088/0031-9155/55/5/004
    • (2010) Phys. Med. Biol. , vol.55 , pp. 1311-1326
    • Ruan, D.1
  • 16
    • 70149108974 scopus 로고    scopus 로고
    • Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm
    • PHMBA7 0031-9155. 10.1088/0031-9155/54/12/014
    • Y. Suh, A. Sawant, R. Venkat, and P. J. Keall, " Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm.," Phys. Med. Biol. PHMBA7 0031-9155 54, 3821-3835 (2009). 10.1088/0031-9155/54/12/014
    • (2009) Phys. Med. Biol. , vol.54 , pp. 3821-3835
    • Suh, Y.1    Sawant, A.2    Venkat, R.3    Keall, P.J.4
  • 17
    • 77952410548 scopus 로고    scopus 로고
    • Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method
    • MPHYA6 0094-2405. 10.1118/1.3319498
    • M. Gui, Y. Feng, B. Yi, A. A. Dhople, and C. Yu, " Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method.," Med. Phys. MPHYA6 0094-2405 37, 1966-1975 (2010). 10.1118/1.3319498
    • (2010) Med. Phys. , vol.37 , pp. 1966-1975
    • Gui, M.1    Feng, Y.2    Yi, B.3    Dhople, A.A.4    Yu, C.5
  • 19
    • 68149149921 scopus 로고    scopus 로고
    • Quality assurance for clinical implementation of an electromagnetic tracking system
    • MPHYA6 0094-2405. 10.1118/1.3158812
    • L. Santanam, C. Noel, T. R. Willoughby, J. Esthappan, S. Mutic, E. E. Klein, D. A. Low, and P. J. Parikh, " Quality assurance for clinical implementation of an electromagnetic tracking system.," Med. Phys. MPHYA6 0094-2405 36, 3477-3486 (2009). 10.1118/1.3158812
    • (2009) Med. Phys. , vol.36 , pp. 3477-3486
    • Santanam, L.1    Noel, C.2    Willoughby, T.R.3    Esthappan, J.4    Mutic, S.5    Klein, E.E.6    Low, D.A.7    Parikh, P.J.8
  • 21
    • 41749111799 scopus 로고    scopus 로고
    • IMRT delivery performance with a Varian multileaf collimator
    • IOBPD3 0360-3016. 10.1016/j.ijrob2007.06.082
    • T. Losasso, " IMRT delivery performance with a Varian multileaf collimator.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 71, S85-S88 (2008). 10.1016/j.ijrobp.2007.06.082
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.71
    • Losasso, T.1
  • 23
    • 51449112251 scopus 로고    scopus 로고
    • Commissioning and quality assurance of RapidArc radiotherapy delivery system
    • IOBPD3 0360-3016. 10.1016/j.ijrob2008.05.060
    • C. C. Ling, P. Zhang, Y. Archambault, J. Bocanek, G. Tang, and T. Losasso, " Commissioning and quality assurance of RapidArc radiotherapy delivery system.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 72, 575-581 (2008). 10.1016/j.ijrobp.2008.05.060
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.72 , pp. 575-581
    • Ling, C.C.1    Zhang, P.2    Archambault, Y.3    Bocanek, J.4    Tang, G.5    Losasso, T.6
  • 24
    • 85027220293 scopus 로고    scopus 로고
    • National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) v4.0.
    • National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) v4.0, http://evs.nci.nih.gov/ftp1/CTCAE/About.html (2009).
    • (2009)
  • 25
    • 65449142560 scopus 로고    scopus 로고
    • Use of the 4D phantom to test real-time targeted radiation therapy device accuracy
    • MPHYA6 0094-2405. 10.1118/1.2761600
    • K. Malinowski, K. Lechleiter, J. Hubenschmidt, D. Low, and P. Parikh, " Use of the 4D phantom to test real-time targeted radiation therapy device accuracy.," Med. Phys. MPHYA6 0094-2405 34, 2611-2611 (2007). 10.1118/1.2761600
    • (2007) Med. Phys. , vol.34 , pp. 2611-2611
    • Malinowski, K.1    Lechleiter, K.2    Hubenschmidt, J.3    Low, D.4    Parikh, P.5
  • 26
    • 77249155934 scopus 로고    scopus 로고
    • A novel optimization based leaf sequencing algorithm with explicit underdose and overdose penalties in 4D radiotherapy
    • IOBPD3 0360-3016. 10.1016/j.ijrob2009.07.1433
    • D. Ruan, A. Sawant, B. C. Cho, P. R. Poulsen, and P. J. Keall, " A novel optimization based leaf sequencing algorithm with explicit underdose and overdose penalties in 4D radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 75, S627-S627 (2009). 10.1016/j.ijrobp.2009.07.1433
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.75
    • Ruan, D.1    Sawant, A.2    Cho, B.C.3    Poulsen, P.R.4    Keall, P.J.5
  • 27
    • 47649126554 scopus 로고    scopus 로고
    • An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients
    • DOI 10.1088/0031-9155/53/13/016, PII S0031915508691010
    • Y. Suh, S. Dieterich, B. Cho, and P. J. Keall, " An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients.," Phys. Med. Biol. PHMBA7 0031-9155 53, 3623-3640 (2008). 10.1088/0031-9155/53/13/016 (Pubitemid 352020045)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.13 , pp. 3623-3640
    • Suh, Y.1    Dieterich, S.2    Cho, B.3    Keall, P.J.4
  • 28
    • 41749093434 scopus 로고    scopus 로고
    • Cyberknife image-guided delivery and quality assurance
    • IOBPD3 0360-3016. 10.1016/j.ijrob2007.08.081
    • S. Dieterich and T. Pawlicki, " Cyberknife image-guided delivery and quality assurance.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 71, S126-S130 (2008). 10.1016/j.ijrobp.2007.08.081
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.71
    • Dieterich, S.1    Pawlicki, T.2
  • 29
    • 0035840765 scopus 로고    scopus 로고
    • A new approach for evaluation of risk priorities of failure modes in FMEA
    • DOI 10.1080/00207540110056162
    • F. Franceschini and M. Galetto, " A new approach for evaluation of risk priorities of failure modes in FMEA.," Int. J. Prod. Res. IJPRB8 0020-7543 39, 2991-3002 (2001). 10.1080/00207540110056162 (Pubitemid 35165556)
    • (2001) International Journal of Production Research , vol.39 , Issue.13 , pp. 2991-3002
    • Franceschini, F.1    Galetto, M.2
  • 30
    • 0037226720 scopus 로고    scopus 로고
    • Modified failure mode and effects analysis using approximate reasoning
    • RESSEP 0951-8320. 10.1016/S0951-8320(02)00179-5
    • A. Pillay and J. Wang, " Modified failure mode and effects analysis using approximate reasoning.," Reliab. Eng. Syst. Saf. RESSEP 0951-8320 79, 69-85 (2003). 10.1016/S0951-8320(02)00179-5
    • (2003) Reliab. Eng. Syst. Saf. , vol.79 , pp. 69-85
    • Pillay, A.1    Wang, J.2
  • 31
    • 33646477009 scopus 로고    scopus 로고
    • Reprioritization of failures in a system failure mode and effects analysis by decision making trial and evaluation laboratory technique
    • RESSEP 0951-8320. 10.1016/j.ress.2005.09.005
    • S. M. Seyed-Hosseini, N. Safaei, and M. J. Asgharpour, " Reprioritization of failures in a system failure mode and effects analysis by decision making trial and evaluation laboratory technique.," Reliab. Eng. Syst. Saf. RESSEP 0951-8320 91, 872-881 (2006). 10.1016/j.ress.2005.09.005
    • (2006) Reliab. Eng. Syst. Saf. , vol.91 , pp. 872-881
    • Seyed-Hosseini, S.M.1    Safaei, N.2    Asgharpour, M.J.3
  • 32
    • 70349554431 scopus 로고    scopus 로고
    • An alternative evaluation of FMEA: Fuzzy art algorithm
    • QREIE5 0748-8017. 10.1002/qre.984
    • G. A. Keskin and C. Ozkan, " An alternative evaluation of FMEA: Fuzzy art algorithm.," Qual. Reliab. Eng. Int QREIE5 0748-8017 25, 647-661 (2009). 10.1002/qre.984
    • (2009) Qual. Reliab. Eng. Int , vol.25 , pp. 647-661
    • Keskin, G.A.1    Ozkan, C.2
  • 33
    • 85027231582 scopus 로고    scopus 로고
    • See supplementary material at E-MPHYA6-37-042012. For more information on supplementary material see.
    • See supplementary material at E-MPHYA6-37-042012. For more information on supplementary material see, http://www/aip/org/pubservs/epaps.html.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.