메뉴 건너뛰기




Volumn 60, Issue 1, 2011, Pages 226-236

State-of-the-art predictive maintenance techniques

Author keywords

LCR testing; loop current step response (LCSR) method; predictive maintenance; time domain reflectrometry (TDR) test; wireless sensor

Indexed keywords

LCR TESTING; LOOP CURRENT; PREDICTIVE MAINTENANCE; TIME-DOMAIN REFLECTROMETRY; WIRELESS SENSOR;

EID: 78650064944     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2010.2047662     Document Type: Conference Paper
Times cited : (200)

References (9)
  • 1
    • 78650041693 scopus 로고    scopus 로고
    • InTech survey: Predictive maintenance top technology challenge in 2007
    • Jan, ISA: International Society of Automation
    • G. Hale, "InTech survey: Predictive maintenance top technology challenge in 2007", InTech2007, Jan. 2007, (ISA: International Society of Automation).
    • (2007) InTech2007
    • Hale, G.1
  • 2
    • 78650069420 scopus 로고    scopus 로고
    • Advanced instrumentation and maintenance technologies for nuclear power plants
    • Chicago, IL, NUREG/CR-5501
    • "Advanced instrumentation and maintenance technologies for nuclear power plants", U. S. Nucl. Regulatory Commission, Chicago, IL, NUREG/CR-5501, 1998.
    • (1998) U. S. Nucl. Regulatory Commission
  • 4
    • 0003690727 scopus 로고
    • Reliability centered maintenance. Report of work by United Airlines for the U. S. department of defense
    • Springfield, VA, Rep. A066-J79
    • F. S. Nowlan and H. F. Heap, "Reliability centered maintenance. Report of work by United Airlines for the U. S. Department of Defense", Nat. Tech. Inf. Service, Springfield, VA, Rep. A066-J79, 1978.
    • (1978) Nat. Tech. Inf. Service
    • Nowlan, F.S.1    Heap, H.F.2
  • 6
    • 78650044150 scopus 로고
    • On-line testing of calibration of process instrumentation channels in nuclear power plants
    • Chicago, IL, NUREG/CR-6343, Nov
    • H. M. Hashemian, "On-line testing of calibration of process instrumentation channels in nuclear power plants", U. S. Nucl. Regulatory Commission, Chicago, IL, NUREG/CR-6343, Nov. 1995.
    • (1995) U. S. Nucl. Regulatory Commission
    • Hashemian, H.M.1
  • 8
    • 37749053830 scopus 로고    scopus 로고
    • Accurately measure the dynamic response of pressure instruments
    • H. M. Hashemian, "Accurately measure the dynamic response of pressure instruments", Po w e r, vol. 151, no. 11, pp. 72-78, 2007.
    • (2007) Po W e r , vol.151 , Issue.11 , pp. 72-78
    • Hashemian, H.M.1
  • 9
    • 34547458655 scopus 로고    scopus 로고
    • Technical review of on-line monitoring techniques for performance assessment-Volume 1: State-of-the-art
    • Chicago, IL, NUREG/CR-6895, Jan
    • J. W. Hines and R. Seibert, "Technical review of on-line monitoring techniques for performance assessment-Volume 1: State-of-the-art", U. S. Nucl. Regulatory Commission, Chicago, IL, NUREG/CR-6895, Jan. 2006.
    • (2006) U. S. Nucl. Regulatory Commission
    • Hines, J.W.1    Seibert, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.