메뉴 건너뛰기




Volumn 34, Issue 12, 2010, Pages 1158-1163

In Vivo Biocompatibility Evaluation of a New Resilient, Hard-Carbon, Thin-Film Coating for Ventricular Assist Devices

Author keywords

Continuous flow pump; Materials testing; Ventricular assist device

Indexed keywords

BLOOD; CARBON; COATINGS; FIBER OPTIC SENSORS; JOURNAL BEARINGS; LEFT VENTRICULAR ASSIST DEVICES; MATERIALS TESTING; PUMPS; STATORS; THIN FILMS;

EID: 78650059798     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00985.x     Document Type: Article
Times cited : (7)

References (8)
  • 1
    • 59649123277 scopus 로고    scopus 로고
    • Development of DexAide right ventricular assist device: update II
    • Fukamachi K, Saeed D, Massiello AL, et al. Development of DexAide right ventricular assist device: update II. ASAIO J 2008;54:589-93.
    • (2008) ASAIO J , vol.54 , pp. 589-593
    • Fukamachi, K.1    Saeed, D.2    Massiello, A.L.3
  • 2
    • 38349148970 scopus 로고    scopus 로고
    • Acute in vivo evaluation of an implantable continuous flow biventricular assist system
    • Saeed D, Ootaki Y, Ootaki C, et al. Acute in vivo evaluation of an implantable continuous flow biventricular assist system. ASAIO J 2008;54:20-4.
    • (2008) ASAIO J , vol.54 , pp. 20-24
    • Saeed, D.1    Ootaki, Y.2    Ootaki, C.3
  • 3
    • 78650061738 scopus 로고    scopus 로고
    • BioMedFlex, LLC. Homepage. Available at: Accessed December 22, 2009.
    • BioMedFlex, LLC. Homepage. Available at: Accessed December 22, 2009.
  • 4
    • 78650065032 scopus 로고    scopus 로고
    • In vitro evaluation of a new resilient, hard-carbon, thin-film coating as a bearing material for ventricular assist devices
    • (in press).
    • Mielke N, Massiello AL, Horvath DJ, et al. In vitro evaluation of a new resilient, hard-carbon, thin-film coating as a bearing material for ventricular assist devices. J Biomed Sci Eng (in press).
    • J Biomed Sci Eng
    • Mielke, N.1    Massiello, A.L.2    Horvath, D.J.3
  • 5
    • 0026717145 scopus 로고
    • Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device
    • Frazier OH, Rose EA, Macmanus Q, et al. Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device. Ann Thorac Surg 1992;53:1080-90.
    • (1992) Ann Thorac Surg , vol.53 , pp. 1080-1090
    • Frazier, O.H.1    Rose, E.A.2    Macmanus, Q.3
  • 7
    • 0030847048 scopus 로고    scopus 로고
    • Cora rotary pump for implantable left ventricular assist device: biomaterial aspects
    • Montiès JR, Dion I, Havlik P, Rouais F, Trinkl J, Baquey C. Cora rotary pump for implantable left ventricular assist device: biomaterial aspects. Artif Organs 1997;21:730-4.
    • (1997) Artif Organs , vol.21 , pp. 730-734
    • Montiès, J.R.1    Dion, I.2    Havlik, P.3    Rouais, F.4    Trinkl, J.5    Baquey, C.6
  • 8
    • 0032888117 scopus 로고    scopus 로고
    • Time-dependent cellular population of textured-surface left ventricular assist devices contributes to the development of a biphasic systemic procoagulant response
    • Spanier TB, Chen JM, Oz MC, Stern DM, Rose EA, Schmidt AM. Time-dependent cellular population of textured-surface left ventricular assist devices contributes to the development of a biphasic systemic procoagulant response. J Thorac Cardiovasc Surg 1999;118:404-13.
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 404-413
    • Spanier, T.B.1    Chen, J.M.2    Oz, M.C.3    Stern, D.M.4    Rose, E.A.5    Schmidt, A.M.6