메뉴 건너뛰기




Volumn 17, Issue 6, 2010, Pages 1764-1771

Analytical computation of discharge characteristic constants and critical parameters of flashover of polluted insulators

Author keywords

critical parameters; discharge characteristic constants; flashover; modeling; Pollution. insulators

Indexed keywords

ANALYTICAL COMPUTATIONS; CRITICAL PARAMETER; CRITICAL VOLTAGES; DISCHARGE CHANNEL; DISCHARGE CHARACTERISTICS; DISCHARGE TEMPERATURE; DYNAMIC EQUATIONS; EQUIVALENT ELECTRICAL CIRCUITS; MATHEMATICAL EXPRESSIONS; MODELING; POLLUTED INSULATORS; POSITIVE POLARITY; THERMAL CHARACTERISTICS;

EID: 78650017539     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2010.5658227     Document Type: Article
Times cited : (85)

References (37)
  • 1
    • 0001423840 scopus 로고
    • Growth of discharges on polluted insulation
    • L. L. Alston and S. Zoledziowski, "Growth of Discharges on Polluted Insulation", Proc. IEE, Vol. 110, pp. 1260-1266, 1963.
    • (1963) Proc. IEE , vol.110 , pp. 1260-1266
    • Alston, L.L.1    Zoledziowski, S.2
  • 3
    • 0015097409 scopus 로고
    • Predetermination of the behaviour of polluted insulators
    • P. Claverie, "Predetermination of the Behaviour of Polluted Insulators", IEEE Trans. Power App. Syst., Vol. 90, pp. 1902-1908, 1971.
    • (1971) IEEE Trans. Power App. Syst. , vol.90 , pp. 1902-1908
    • Claverie, P.1
  • 4
    • 33749885201 scopus 로고
    • The reignition voltage characteristics of freely recovering
    • F. W. Crawford and H. Edels, "The Reignition Voltage Characteristics of Freely Recovering", Proc. IEE, Vol. 107, pp. 202-212, 1960.
    • (1960) Proc. IEE , vol.107 , pp. 202-212
    • Crawford, F.W.1    Edels, H.2
  • 5
    • 33749921861 scopus 로고
    • Arc interruption and thermal reignition
    • H. Edels, "Arc Interruption and Thermal Reignition", Proc. IEE, Vol. 109, pp. 89-98, 1962.
    • (1962) Proc. IEE , vol.109 , pp. 89-98
    • Edels, H.1
  • 6
    • 0003160903 scopus 로고
    • Mathematical models for pollution flashover
    • F. A. M. Rizk, "Mathematical Models for Pollution Flashover", Electra, Vol. 78, pp. 71-103, 1981.
    • (1981) Electra , vol.78 , pp. 71-103
    • Rizk, F.A.M.1
  • 7
    • 0001430745 scopus 로고
    • Flashover mechanism of polluted insulation
    • B. F. Hampton, "Flashover Mechanism of Polluted Insulation", Proc. IEE, Vol. 111, pp. 985-990, 1964.
    • (1964) Proc. IEE , vol.111 , pp. 985-990
    • Hampton, B.F.1
  • 8
    • 0001462519 scopus 로고
    • Flashover voltage of HV insulators with uniform surface pollution films
    • R. Wilkins, "Flashover Voltage of HV Insulators with Uniform Surface Pollution Films", Proc IEE, Vol. 116, pp. 457-465, 1969.
    • (1969) Proc. IEE , vol.116 , pp. 457-465
    • Wilkins, R.1
  • 10
    • 0027579052 scopus 로고
    • Dynamic arc modelling of pollution flashover of insulators under dc voltage
    • R. Sundararajan and R. S. Gorur, "Dynamic Arc Modelling of Pollution Flashover of Insulators under dc Voltage", IEEE Trans. Electr. Insul., Vol. 28, pp. 209-219, 1993.
    • (1993) IEEE Trans. Electr. Insul. , vol.28 , pp. 209-219
    • Sundararajan, R.1    Gorur, R.S.2
  • 12
    • 0000445401 scopus 로고
    • Fremdschichtüberschlag und Kriechweglänge
    • F. Obenaus, "Fremdschichtüberschlag und Kriechweglä nge", Deutsche Electrotechnik, Vol. 4, pp. 135-136, 1958.
    • (1958) Deutsche Electrotechnik , vol.4 , pp. 135-136
    • Obenaus, F.1
  • 13
    • 0015617925 scopus 로고
    • How to choose Insulators for polluted Areas
    • P. Claverie, Y. Porcheron, "How to choose Insulators for polluted Areas", IEEE Trans. Power App. Syst., Vol. 92, pp. 1121-1131, 1973.
    • (1973) IEEE Trans. Power App. Syst. , vol.92 , pp. 1121-1131
    • Claverie, P.1    Porcheron, Y.2
  • 14
    • 0025469745 scopus 로고
    • Calculation of dc and ac flashover voltage of polluted insulators
    • Guan Zhanga and Zhang Renyu, "Calculation of dc and ac Flashover Voltage of Polluted Insulators", IEEE Trans. Electr. Insul., Vol. 25, pp. 723-728, 1990.
    • (1990) IEEE Trans. Electr. Insul. , vol.25 , pp. 723-728
    • Zhanga, G.1    Renyu, Z.2
  • 18
    • 0000248618 scopus 로고
    • DC interfacial breakdown on contaminated electrolytic surfaces
    • T. C. Chen, H. I. M. Nour and C. Y. Wu, "DC Interfacial Breakdown on Contaminated Electrolytic Surfaces", IEEE Trans. Electr. Insul., Vol. 19, pp. 536-542, 1984.
    • (1984) IEEE Trans. Electr. Insul. , vol.19 , pp. 536-542
    • Chen, T.C.1    Nour, H.I.M.2    Wu, C.Y.3
  • 19
    • 65949098652 scopus 로고    scopus 로고
    • Investigation on influence of salts mixture on the determination of flashover discharge constant Part I: A preliminary study
    • M. El-A. Slama, H. Hadi and S. Flazi, "Investigation on Influence of Salts Mixture on the Determination of Flashover Discharge Constant Part I: A Preliminary Study", IEEE Conf. Electr. Insul. Dielectr. Phenomena (CEIDP). Vancouver Canada, pp. 674-677, 2008.
    • (2008) IEEE Conf. Electr. Insul. Dielectr. Phenomena (CEIDP). Vancouver Canada , pp. 674-677
    • Slama, M.El-A.1    Hadi, H.2    Flazi, S.3
  • 21
    • 0031124947 scopus 로고    scopus 로고
    • Modeling of altitude effects on AC flashover of polluted HV insulators
    • F. A. M. Rizk and A. Q. Rezazada, "Modeling of altitude effects on AC flashover of polluted HV insulators", IEEE Trans. Power Delivery, Vol. 12, No. 2, pp. 810-822, 1997
    • (1997) IEEE Trans. Power Delivery , vol.12 , Issue.2 , pp. 810-822
    • Rizk, F.A.M.1    Rezazada, A.Q.2
  • 22
    • 33749947879 scopus 로고
    • Verschmutzungszustand und Kriechweg
    • Wiss., Berlin
    • G. Neumarker, "Verschmutzungszustand und Kriechweg", Monatsber. D. Deut. Akad, Wiss., Berlin, Vol. 1, pp. 352-359, 1959.
    • (1959) Monatsber. D. Deut. Akad , vol.1 , pp. 352-359
    • Neumarker, G.1
  • 23
    • 0033741947 scopus 로고    scopus 로고
    • Flashover dynamic model of polluted insulators under ac voltage
    • N. Dhahbi-Megriche and A. Beroual, "Flashover Dynamic Model of Polluted Insulators under ac Voltage", IEEE Trans. Dielectr. Electr. Insul., Vol. 7, pp. 283-289, 2000.
    • (2000) IEEE Trans. Dielectr. Electr. Insul. , vol.7 , pp. 283-289
    • Dhahbi-Megriche, N.1    Beroual, A.2
  • 29
    • 33645530799 scopus 로고
    • An asymptotic treatment of the Elenbaas-Heller equation for a radiating wall-stabilized high-pressure gas-discharge arc
    • H. K. Kuiken, "An asymptotic treatment of the Elenbaas-Heller equation for a radiating wall-stabilized high-pressure gas-discharge arc", J. Appl. Phys. Vol. 70, pp. 5282-5291, 1991.
    • (1991) J. Appl. Phys. , vol.70 , pp. 5282-5291
    • Kuiken, H.K.1
  • 34
    • 0024167591 scopus 로고
    • Polarity effect in DC withstand voltages of contaminated surfaces
    • M. lshii and H. Ohashi, "Polarity Effect in DC Withstand Voltages of Contaminated Surfaces", IEEE Trans. Electr. Insul., Vol. 23, pp. 1033-1042, 1988.
    • (1988) IEEE Trans. Electr. Insul. , vol.23 , pp. 1033-1042
    • Lshii, M.1    Ohashi, H.2
  • 35
    • 56249140762 scopus 로고    scopus 로고
    • Studies on erosion of silicone rubber exposed to partial arc discharge
    • K. Haji, Y. Zhu, M. Otsubo and T. Sakoda, "Studies on erosion of silicone rubber exposed to partial arc discharge", Polymer degradation and stability, Vol. 93, pp. 2214-2221, 2008.
    • (2008) Polymer. Degradation and Stability , vol.93 , pp. 2214-2221
    • Haji, K.1    Zhu, Y.2    Otsubo, M.3    Sakoda, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.