메뉴 건너뛰기




Volumn 55, Issue 22, 2010, Pages 6739-6757

AB-OSEM reconstruction for improved Patlak kinetic parameter estimation: A simulation study

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVITY CONCENTRATION; COLD REGIONS; COMPETING ALGORITHMS; CURRENT ANALYSIS; DYNAMIC IMAGING; DYNAMIC PET; FORWARD MODELS; HIGH-RESOLUTION RESEARCH TOMOGRAPH; ITERATION NUMBERS; LOWER BOUNDS; NON-NEGATIVITY; OSEM RECONSTRUCTION; PARAMETRIC IMAGE; PARAMETRIC IMAGING; POSITIVE BIAS; RECONSTRUCTED IMAGE; RECONSTRUCTION METHOD; ROOT MEAN SQUARED ERRORS; SIMULATION STUDIES; STANDARD DEVIATION;

EID: 78650010663     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/22/009     Document Type: Article
Times cited : (27)

References (20)
  • 2
    • 0031675604 scopus 로고    scopus 로고
    • Accelerating theEMMLalgorithm and related iterative algorithms by rescaled block-iterative methods
    • Byrne C 1998a Accelerating theEMMLalgorithm and related iterative algorithms by rescaled block-iterative methods IEEE Trans. Image Process. 7 100-9
    • (1998) IEEE Trans. Image Process. , vol.7 , pp. 100-109
    • Byrne, C.1
  • 3
    • 0001183858 scopus 로고    scopus 로고
    • Iterative algorithms for deblurring and deconvolution with constraints
    • Byrne C 1998b Iterative algorithms for deblurring and deconvolution with constraints Inverse Problems 14 1455-67
    • (1998) Inverse Problems , vol.14 , pp. 1455-1467
    • Byrne, C.1
  • 8
    • 0028700063 scopus 로고
    • Accelerated image-reconstruction using ordered subsets of projection data
    • Hudson H M and Larkin R S 1994 Accelerated image-reconstruction using ordered subsets of projection data IEEE Trans. Med. Imaging 13 601-9
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 9
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K and Carson R 1984 EM reconstruction algorithms for emission and transmission tomography J. Comput. Assist. Tomogr. 8 306-16
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 11
    • 0036321928 scopus 로고    scopus 로고
    • Reducing loss of image quality because of the attenuation artifact in uncorrected PET whole-body images
    • Nuyts J, Stroobants S, Dupont P, Vleugels S, Flamen P and Mortelmans L 2002 Reducing loss of image quality because of the attenuation artifact in uncorrected PET whole-body images J. Nucl. Med. 43 1054-62
    • (2002) J. Nucl. Med. , vol.43 , pp. 1054-1062
    • Nuyts, J.1    Stroobants, S.2    Dupont, P.3    Vleugels, S.4    Flamen, P.5    Mortelmans, L.6
  • 12
    • 0018582265 scopus 로고
    • Tomographic measurement of local cerebral glucose metabolic-rate in humans with (F-18)2-Fluoro-2-Deoxy-D-Glucose: Validation ofmethod
    • Phelps M E, Huang S C, Hoffman E J, Selin C, Sokoloff L and Kuhl D E 1979 Tomographic measurement of local cerebral glucose metabolic-rate in humans with (F-18)2-Fluoro-2-Deoxy-D-Glucose: validation ofmethod Ann. Neurol. 6 371-88
    • (1979) Ann. Neurol. , vol.6 , pp. 371-388
    • Phelps, M.E.1    Huang, S.C.2    Hoffman, E.J.3    Selin, C.4    Sokoloff, L.5    Kuhl, D.E.6
  • 13
    • 43149117030 scopus 로고    scopus 로고
    • Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events
    • Rahmim A et al 2008 Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events IEEE Trans. Med. Imaging 27 1018-33
    • (2008) IEEE Trans. Med. Imaging , vol.27 , pp. 1018-1033
    • Rahmim, A.1
  • 14
    • 36148937522 scopus 로고    scopus 로고
    • Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies
    • Reilhac A, Tomei S, Buvat I, Michell C, Keheren F and Costes N 2008 Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies Neuroimage 39 359-68
    • (2008) Neuroimage , vol.39 , pp. 359-368
    • Reilhac, A.1    Tomei, S.2    Buvat, I.3    Michell, C.4    Keheren, F.5    Costes, N.6
  • 15
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L A and Vardi Y 1982 Maximum likelihood reconstruction for emission tomography IEEE Trans. Med. Imaging MI-1 113-22
    • (1982) IEEE Trans. Med. Imaging , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 16
    • 41449108094 scopus 로고    scopus 로고
    • Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography
    • Tsoumpas C, Turkheimer F E and Thielemans K 2008 Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography Med. Phys. 35 1299-309
    • (2008) Med. Phys. , vol.35 , pp. 1299-1309
    • Tsoumpas, C.1    Turkheimer, F.E.2    Thielemans, K.3
  • 18
    • 45949099893 scopus 로고    scopus 로고
    • Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for high-resolution research tomograph studies: Effects of randoms estimation methods
    • van Velden F H P, Kloet R W, van Berckel B N M, Wolfensberger S P A, Lammertsma A A and Boellaard R 2008 Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for high-resolution research tomograph studies: effects of randoms estimation methods Phys. Med. Biol. 53 3217-30
    • (2008) Phys. Med. Biol. , vol.53 , pp. 3217-3230
    • Van Velden, F.H.P.1    Kloet, R.W.2    Van Berckel, B.N.M.3    Wolfensberger, S.P.A.4    Lammertsma, A.A.5    Boellaard, R.6
  • 19
    • 78650022475 scopus 로고    scopus 로고
    • Task-oriented quantitative image reconstruction in emission tomography for single- and multi-subject studies
    • in press
    • Verhaeghe J, Gravel P and Reader A J 2010 Task-oriented quantitative image reconstruction in emission tomography for single- and multi-subject studies Phys. Med. Biol. in press
    • (2010) Phys. Med. Biol.
    • Verhaeghe, J.1    Gravel, P.2    Reader, A.J.3
  • 20
    • 0036464422 scopus 로고    scopus 로고
    • The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph
    • Wienhard K et al 2002 The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph IEEE Trans. Nucl. Sci. 49 104-10
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 104-110
    • Wienhard, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.