메뉴 건너뛰기




Volumn 17 IFMBE, Issue , 2007, Pages 408-411

Four-dimensional regularization for electrical impedance tomography imaging

Author keywords

Electrical impedance tomography; Image reconstruction; Regularization; Spatial and temporal priors

Indexed keywords

ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; MATRIX ALGEBRA;

EID: 78649963581     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-73841-1_106     Document Type: Conference Paper
Times cited : (3)

References (8)
  • 1
    • 16444370982 scopus 로고    scopus 로고
    • A 1000-measurement frames/second ERT data capture system with real-time visualization
    • DOI 10.1109/JSEN.2004.842445
    • Wilkinson A J, Randall E W, Cilliers J J, Durrett D R, Naidoo T and Long T (2005) A 1000-measurement frames/second ERT data capture system with real-time visualization, IEEE Sensors Journal 5 300-307 (Pubitemid 40476007)
    • (2005) IEEE Sensors Journal , vol.5 , Issue.2 , pp. 300-307
    • Wilkinson, A.J.1    Randall, E.W.2    Cilliers, J.J.3    Durrett, D.R.4    Naidoo, T.5    Long, T.6
  • 2
    • 23044475008 scopus 로고    scopus 로고
    • Excitation patterns in three-dimensional electrical impedance tomography
    • DOI 10.1088/0967-3334/26/2/018
    • Dehgani H, Soni N, Halter R, Hartov A and Paulsen K D (2005) Excitation patterns in three-dimensional electrical impedance tomography, Physiol. Meas. 26 S185-S197 (Pubitemid 41223613)
    • (2005) Physiological Measurement , vol.26 , Issue.2
    • Dehghani, H.1    Soni, N.2    Halter, R.3    Hartov, A.4    Paulsen, K.D.5
  • 3
    • 34447106435 scopus 로고    scopus 로고
    • Electrode Placement Configurations for 3D EIT
    • Mar 2007
    • Graham B and Adler A (2007) Electrode Placement Configurations for 3D EIT, Physiol. Meas. Mar 2007
    • (2007) Physiol. Meas.
    • Graham, B.1    Adler, A.2
  • 4
    • 0032819129 scopus 로고    scopus 로고
    • Three-dimensional electrical impedance tomography based on the complete electrode model
    • Vauhkonen P J, Vauhkonen M, Savolainen T and Kaipio J P (1999) Three-dimensional electrical impedance tomography based on the complete electrode model, IEEE Trans, Biomedical Engineering, Vol 46, Issue 9, 1150-1160
    • (1999) IEEE Trans, Biomedical Engineering , vol.46 , Issue.9 , pp. 1150-1160
    • Vauhkonen, P.J.1    Vauhkonen, M.2    Savolainen, T.3    Kaipio, J.P.4
  • 5
    • 0032053399 scopus 로고    scopus 로고
    • A Kalman filter approach to track fast impendance changes in electrical impedance tomography
    • DOI 10.1109/10.664204
    • Vauhkonen M, Karjalainen P A, Kaipio J P (1998) A Kalman filter approach to track fast impedance changes in electrical impedance tomography, IEEE Trans. Biomed. Eng,45 486-493 (Pubitemid 28141772)
    • (1998) IEEE Transactions on Biomedical Engineering , vol.45 , Issue.4 , pp. 486-493
    • Vauhkonen, M.1    Karjalainen, P.A.2    Kaipio, J.P.3
  • 7
    • 33745137848 scopus 로고    scopus 로고
    • Uses and abuses of EIDORS: An extensible software base for EIT
    • DOI 10.1088/0967-3334/27/5/S03, PII S0967333406120390, S03
    • Adler A and Lionheart W R B (2006) Uses and abuses of EIDORS: An extensible software base for EIT, Physiol. Meas. 27 S25-S42 (Pubitemid 43890631)
    • (2006) Physiological Measurement , vol.27 , Issue.5
    • Adler, A.1    Lionheart, W.R.B.2
  • 8
    • 34447096601 scopus 로고    scopus 로고
    • Temporal Image Reconstruction in Electrical Impedance Tomography
    • In press, April 2007
    • Adler A, Dai T and Lionheart W R B (2007) Temporal Image Reconstruction in Electrical Impedance Tomography, In press, Physiol. Meas., April 2007
    • (2007) Physiol. Meas.
    • Adler, A.1    Dai, T.2    Lionheart, W.R.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.