Volumn 54, Issue 4, 2011, Pages 975-982

Non-invasive measurement of the human core temperature

Author keywords

Human temperature; Non invasive; Temperature measurement; Thermal instrumentation

Indexed keywords

BIO-HEAT EQUATIONS; CONTROL ALGORITHMS; CORE TEMPERATURE; DIRECT MEASUREMENT; FOREHEAD SKIN; FOURIER HEAT CONDUCTION; HUMAN BODIES; HUMAN TEMPERATURE; MODEL PROBLEMS; NEW APPROACHES; NON-INVASIVE; NONINVASIVE MEASUREMENTS; NUMERICAL SIMULATION; OPTIMIZATION ROUTINE; PATIENT HEALTH; SENSING SYSTEMS; SENSOR SYSTEMS; TEMPERATURE VALUES; THERMAL INSTRUMENTATION; TIME VARYING; TISSUE LAYERS; TRANSIENT MODES;

EID: 78649934901     PISSN: 00179310     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijheatmasstransfer.2010.09.042     Document Type: Article
Times cited : (25)

References (20)
  • 1
    • 0014987164 scopus 로고
    • A new technique for monitoring the deep body temperature in man from the intact skin surface
    • R. Fox, and A. Solman A new technique for monitoring the deep body temperature in man from the intact skin surface J. Physiol. 212 1971 8 10
    • (1971) J. Physiol. , vol.212 , pp. 8-10
    • Fox, R.1    Solman, A.2
  • 2
    • 0015547160 scopus 로고
    • A new method for monitoring deep body temperature from the skin surface
    • R. Fox, A. Solman, R. Isaacs, A. Fry, and I. MacDonald A new method for monitoring deep body temperature from the skin surface Clin. Sci. 44 1973 81 86
    • (1973) Clin. Sci. , vol.44 , pp. 81-86
    • Fox, R.1    Solman, A.2    Isaacs, R.3    Fry, A.4    MacDonald, I.5
  • 4
    • 0015677269 scopus 로고
    • New thermometers for deep tissue temperature
    • A. Solman, and J. Dalton New thermometers for deep tissue temperature Biomed. Eng. 8 1973 432 435
    • (1973) Biomed. Eng. , vol.8 , pp. 432-435
    • Solman, A.1    Dalton, J.2
  • 5
    • 0021824079 scopus 로고
    • Body temperature measurement
    • T. Togwa Body temperature measurement Clin. Phys. Physiol. Meas. 6 1985 83 108
    • (1985) Clin. Phys. Physiol. Meas. , vol.6 , pp. 83-108
    • Togwa, T.1
  • 7
    • 0003306801 scopus 로고
    • Non-invasive deep body temperature measurement
    • T. Togwa, and T. Nemoto Non-invasive deep body temperature measurement Non-Invasive Physiol. Meas. 1 1979 261 277
    • (1979) Non-Invasive Physiol. Meas. , vol.1 , pp. 261-277
    • Togwa, T.1    Nemoto, T.2
  • 8
    • 0018563376 scopus 로고
    • Deep temperature monitoring in intensive care
    • T. Togwa, T. Nemoto, T. Tsuji, and K. Suma Deep temperature monitoring in intensive care Resuscitation 7 1979 53 57
    • (1979) Resuscitation , vol.7 , pp. 53-57
    • Togwa, T.1    Nemoto, T.2    Tsuji, T.3    Suma, K.4
  • 9
    • 0037943779 scopus 로고
    • Medical thermometer making use of zero-heat-flow method
    • T. Togwa, and T. Nemoto Medical thermometer making use of zero-heat-flow method Rep. Inst. Med. Dent. Eng. 7 1973 75 83
    • (1973) Rep. Inst. Med. Dent. Eng. , vol.7 , pp. 75-83
    • Togwa, T.1    Nemoto, T.2
  • 11
    • 0036948211 scopus 로고    scopus 로고
    • Evaluation of a newly developed monitor of deep body temperature
    • M. Yamakage, S. Iwasaki, and A. Namiki Evaluation of a newly developed monitor of deep body temperature J. Anesth. 16 2002 354 357
    • (2002) J. Anesth. , vol.16 , pp. 354-357
    • Yamakage, M.1    Iwasaki, S.2    Namiki, A.3
  • 12
    • 22144462818 scopus 로고    scopus 로고
    • Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement
    • D. Brajkovic, and M. Ducharme Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement Eur. J. Appl. Physiol. 94 2005 386 391
    • (2005) Eur. J. Appl. Physiol. , vol.94 , pp. 386-391
    • Brajkovic, D.1    Ducharme, M.2
  • 13
    • 24044525323 scopus 로고    scopus 로고
    • Modeling of temperature and perfusion during scalp cooling
    • F. Janssen, G. Van Leeuwen, and A. Van Steenhoven Modeling of temperature and perfusion during scalp cooling Phys. Med. Biol. 50 2005 4065 4073
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4065-4073
    • Janssen, F.1    Van Leeuwen, G.2    Van Steenhoven, A.3
  • 14
    • 0017096709 scopus 로고
    • A mathematical model of the human temperature regulatory system - Transient cold exposure response
    • R. Gordon, R. Roemer, and S. Horvath A mathematical model of the human temperature regulatory system - transient cold exposure response IEEE Trans. Biomed. Eng. BME-23 1976 434 444
    • (1976) IEEE Trans. Biomed. Eng. , vol.23 , pp. 434-444
    • Gordon, R.1    Roemer, R.2    Horvath, S.3
  • 15
    • 0023772184 scopus 로고
    • Temperature profiles with respect to inhomogeneity and geometry of the human body
    • J. Werner, and M. Buse Temperature profiles with respect to inhomogeneity and geometry of the human body J. Appl. Physiol. 65 1988 1110 1118
    • (1988) J. Appl. Physiol. , vol.65 , pp. 1110-1118
    • Werner, J.1    Buse, M.2
  • 16
    • 0006742816 scopus 로고
    • Regional differences in the basal and maximal rates of blood flow in the skin
    • A. Hertzman, and W. Randall Regional differences in the basal and maximal rates of blood flow in the skin J. Appl. Physiol. 1 1948 234 241
    • (1948) J. Appl. Physiol. , vol.1 , pp. 234-241
    • Hertzman, A.1    Randall, W.2
  • 17
    • 0032962951 scopus 로고    scopus 로고
    • A mathematical model for human brain cooling during cold-water near-drowning
    • X. Xu, P. Tikuisis, and G. Giesbrecht A mathematical model for human brain cooling during cold-water near-drowning J. Appl. Physiol. 86 1999 265 272
    • (1999) J. Appl. Physiol. , vol.86 , pp. 265-272
    • Xu, X.1    Tikuisis, P.2    Giesbrecht, G.3
  • 18
    • 0028860152 scopus 로고
    • Fluid distribution and tissue thickness changes in 29 men during 1 week at moderate altitude (2,315 m)
    • H. Gunga Fluid distribution and tissue thickness changes in 29 men during 1 week at moderate altitude (2,315 m) Eur. J. Appl. Physiol. 70 1995 1 5
    • (1995) Eur. J. Appl. Physiol. , vol.70 , pp. 1-5
    • Gunga, H.1
  • 19
    • 0031132414 scopus 로고    scopus 로고
    • Convective and radiative heat transfer coefficients for individual human body segments
    • R. de Dear, E. Arens, and Z. Hui Convective and radiative heat transfer coefficients for individual human body segments Int. J. Biometeorol. 40 1997 141 156
    • (1997) Int. J. Biometeorol. , vol.40 , pp. 141-156
    • De Dear, R.1    Arens, E.2    Hui, Z.3
  • 20
    • 34247634178 scopus 로고
    • New measurements of the convective heat transfer coefficient: Influences of turbulence, mean air velocity and geometry of the human body
    • E. Mayer New measurements of the convective heat transfer coefficient: influences of turbulence, mean air velocity and geometry of the human body Proc. Roomvent 3 1992 263 276
    • (1992) Proc. Roomvent , vol.3 , pp. 263-276
    • Mayer, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.