메뉴 건너뛰기




Volumn 76, Issue 6, 2010, Pages 1512-1516

A 7% decrease in the differential renal uptake of MAG3 implies a loss in renal function

Author keywords

[No Author keywords available]

Indexed keywords

CREATININE; MERTIATIDE TC 99M;

EID: 78649906689     PISSN: 00904295     EISSN: 15279995     Source Type: Journal    
DOI: 10.1016/j.urology.2010.03.066     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 0033008416 scopus 로고    scopus 로고
    • Radionuclide renography: A personal approach
    • A. Taylor Radionuclide renography: a personal approach Semin Nucl Med 29 1999 102 127
    • (1999) Semin Nucl Med , vol.29 , pp. 102-127
    • Taylor, A.1
  • 2
    • 0026847481 scopus 로고
    • Technetium-99m (99mTc) mercaptoacetyltriglycine: Update on the new 99m Tc renal tubular function agent
    • D. Eshima, and A. Taylor Jr Technetium-99m (99mTc) mercaptoacetyltriglycine: update on the new 99m Tc renal tubular function agent Semin Nucl Med 22 1992 61 73
    • (1992) Semin Nucl Med , vol.22 , pp. 61-73
    • Eshima, D.1    Taylor Jr., A.2
  • 3
    • 0028041110 scopus 로고
    • Technetium-99m-MAG3 renal studies: Normal range and reproducibility of physiologic parameters as a function of age and sex
    • W.C. Klingensmith, D.E. Briggs, and W.I. Smith Technetium-99m-MAG3 renal studies: normal range and reproducibility of physiologic parameters as a function of age and sex J Nucl Med 35 1994 1612 1617
    • (1994) J Nucl Med , vol.35 , pp. 1612-1617
    • Klingensmith, W.C.1    Briggs, D.E.2    Smith, W.I.3
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet i 1986 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 38949166678 scopus 로고    scopus 로고
    • Diagnostic performance of an expert system for interpretation of Tc-99m MAG3 scans in suspected obstruction
    • A. Taylor, E.V. Garcia, J.N.G. Binongo, and A. Manatunga Diagnostic performance of an expert system for interpretation of Tc-99m MAG3 scans in suspected obstruction J Nucl Med 49 2008 216 224
    • (2008) J Nucl Med , vol.49 , pp. 216-224
    • Taylor, A.1    Garcia, E.V.2    Binongo, J.N.G.3    Manatunga, A.4
  • 7
    • 0035080564 scopus 로고    scopus 로고
    • Guidelines for standard and diuretic renography in children
    • I. Gordon, P. Colarinha, and J. Fettich Guidelines for standard and diuretic renography in children Eur J Nucl Med 28 2001 BP31 BP36
    • (2001) Eur J Nucl Med , vol.28
    • Gordon, I.1    Colarinha, P.2    Fettich, J.3
  • 8
    • 0037323937 scopus 로고    scopus 로고
    • Standardization of the renogram technique for investigating the dilated upper urinary tract and assessing the results of surgery
    • P.H. O'Reilly Standardization of the renogram technique for investigating the dilated upper urinary tract and assessing the results of surgery BJU Int 91 2003 239 243
    • (2003) BJU Int , vol.91 , pp. 239-243
    • O'Reilly, P.H.1
  • 9
    • 0032969865 scopus 로고    scopus 로고
    • Consensus report on quality control of quantitative measurements of renal function obtained from the renogram
    • A. Prigent, P. Cosgriff, and G.F. Gates Consensus report on quality control of quantitative measurements of renal function obtained from the renogram Semin Nucl Med 29 1999 146 159
    • (1999) Semin Nucl Med , vol.29 , pp. 146-159
    • Prigent, A.1    Cosgriff, P.2    Gates, G.F.3
  • 10
    • 10344260673 scopus 로고    scopus 로고
    • Consensus report on ACE inhibitor renography for detecting renovascular hypertension
    • A. Taylor, J. Nally, and M. Aurell Consensus report on ACE inhibitor renography for detecting renovascular hypertension J Nucl Med 37 1996 1876 1882
    • (1996) J Nucl Med , vol.37 , pp. 1876-1882
    • Taylor, A.1    Nally, J.2    Aurell, M.3
  • 11
    • 33947200567 scopus 로고    scopus 로고
    • 99mTc -MAG3 clearance, MAG3 curve parameters, excretory parameters and residual urine volume
    • 99mTc -MAG3 clearance, MAG3 curve parameters, excretory parameters and residual urine volume AJR Am J Roentgenol 187 2006 W610 W617
    • (2006) AJR Am J Roentgenol , vol.187
    • Esteves, F.P.1    Taylor, A.2    Manatunga, A.3
  • 12
    • 1842328061 scopus 로고    scopus 로고
    • Background subtraction in Tc-99m MAG3 renography
    • A. Taylor, K. Thakore, and R. Folks Background subtraction in Tc-99m MAG3 renography J Nucl Med 38 1997 74 79
    • (1997) J Nucl Med , vol.38 , pp. 74-79
    • Taylor, A.1    Thakore, K.2    Folks, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.