-
1
-
-
56949105809
-
Defibrillation or cardiopulmonary resuscitation first for patients with out-of-hospital cardiac arrests found by paramedics to be in ventricular fibrillation? A randomised control trial
-
Baker PW, Conway J, Cotton C, et al. Defibrillation or cardiopulmonary resuscitation first for patients with out-of-hospital cardiac arrests found by paramedics to be in ventricular fibrillation? A randomised control trial. Resuscitation 2008;79:424-31.
-
(2008)
Resuscitation
, vol.79
, pp. 424-431
-
-
Baker, P.W.1
Conway, J.2
Cotton, C.3
-
2
-
-
13544262488
-
CPR before defibrillation in out-of-hospital cardiac arrest: a randomized trial
-
Jacobs IG, Finn JC, Oxer HF, Jelinek GA. CPR before defibrillation in out-of-hospital cardiac arrest: a randomized trial. Emerg Med Australas 2005;17:39-45.
-
(2005)
Emerg Med Australas
, vol.17
, pp. 39-45
-
-
Jacobs, I.G.1
Finn, J.C.2
Oxer, H.F.3
Jelinek, G.A.4
-
3
-
-
65449175658
-
Shortening of cardiopulmonary resuscitation time before the defibrillation worsens the outcome in out-of-hospital VF patients
-
Hayakawa M, Gando S, Okamoto H, Asai Y, Uegaki S, Makise H. Shortening of cardiopulmonary resuscitation time before the defibrillation worsens the outcome in out-of-hospital VF patients. Am J Emerg Med 2009;27:470-4.
-
(2009)
Am J Emerg Med
, vol.27
, pp. 470-474
-
-
Hayakawa, M.1
Gando, S.2
Okamoto, H.3
Asai, Y.4
Uegaki, S.5
Makise, H.6
-
4
-
-
74649084037
-
Survival increases with CPR by Emergency Medical Services before defibrillation of out-of-hospital ventricular fibrillation or ventricular tachycardia: observations from the Resuscitation Outcomes Consortium
-
Bradley SM, Gabriel EE, Aufderheide TP, et al. Survival increases with CPR by Emergency Medical Services before defibrillation of out-of-hospital ventricular fibrillation or ventricular tachycardia: observations from the Resuscitation Outcomes Consortium. Resuscitation 2010;81:155-62.
-
(2010)
Resuscitation
, vol.81
, pp. 155-162
-
-
Bradley, S.M.1
Gabriel, E.E.2
Aufderheide, T.P.3
-
5
-
-
0037454292
-
Delaying defibrillation to give basic cardiopulmonary resuscitation to patients with out-of-hospital ventricular fibrillation: a randomized trial
-
Wik L, Hansen TB, Fylling F, et al. Delaying defibrillation to give basic cardiopulmonary resuscitation to patients with out-of-hospital ventricular fibrillation: a randomized trial. JAMA 2003;289:1389-95.
-
(2003)
JAMA
, vol.289
, pp. 1389-1395
-
-
Wik, L.1
Hansen, T.B.2
Fylling, F.3
-
6
-
-
0033531690
-
Influence of cardiopulmonary resuscitation prior to defibrillation in patients with out-of-hospital ventricular fibrillation
-
Cobb LA, Fahrenbruch CE, Walsh TR, et al. Influence of cardiopulmonary resuscitation prior to defibrillation in patients with out-of-hospital ventricular fibrillation. JAMA 1999;281:1182-8.
-
(1999)
JAMA
, vol.281
, pp. 1182-1128
-
-
Cobb, L.A.1
Fahrenbruch, C.E.2
Walsh, T.R.3
-
7
-
-
0023195551
-
Self-adhesive monitor/defibrillation pads improve prehospital defibrillation success
-
Stults KR, Brown DD, Cooley F, Kerber RE. Self-adhesive monitor/defibrillation pads improve prehospital defibrillation success. Ann Emerg Med 1987;16:872-7.
-
(1987)
Ann Emerg Med
, vol.16
, pp. 872-877
-
-
Stults, K.R.1
Brown, D.D.2
Cooley, F.3
Kerber, R.E.4
-
8
-
-
0023709169
-
Use of self-adhesive external defibrillator pads for complex cardiac surgical procedures
-
Bojar RM, Payne DD, Rastegar H, Diehl JT, Cleveland RJ. Use of self-adhesive external defibrillator pads for complex cardiac surgical procedures. Ann Thorac Surg 1988;46:587-8.
-
(1988)
Ann Thorac Surg
, vol.46
, pp. 587-588
-
-
Bojar, R.M.1
Payne, D.D.2
Rastegar, H.3
Diehl, J.T.4
Cleveland, R.J.5
-
9
-
-
0034839486
-
Cardiac arrest during surgery and ventilation in the prone position: a case report and systematic review
-
Brown J, Rogers J, Soar J. Cardiac arrest during surgery and ventilation in the prone position: a case report and systematic review. Resuscitation 2001;50:233-8.
-
(2001)
Resuscitation
, vol.50
, pp. 233-238
-
-
Brown, J.1
Rogers, J.2
Soar, J.3
-
10
-
-
0023255990
-
Defibrillation of high-risk patients during coronary angiography using self-adhesive, preapplied electrode pads
-
Wilson RF, Sirna S, White CW, Kerber RE. Defibrillation of high-risk patients during coronary angiography using self-adhesive, preapplied electrode pads. Am J Cardiol 1987;60:380-2.
-
(1987)
Am J Cardiol
, vol.60
, pp. 380-382
-
-
Wilson, R.F.1
Sirna, S.2
White, C.W.3
Kerber, R.E.4
-
11
-
-
0034026930
-
Reliability of ECG monitoring with a gel pad/paddle combination after defibrillation
-
Bradbury N, Hyde D, Nolan J. Reliability of ECG monitoring with a gel pad/paddle combination after defibrillation. Resuscitation 2000;44:203-6.
-
(2000)
Resuscitation
, vol.44
, pp. 203-206
-
-
Bradbury, N.1
Hyde, D.2
Nolan, J.3
-
12
-
-
33847375654
-
The impact of manual defibrillation technique on no-flow time during simulated cardiopulmonary resuscitation
-
Perkins GD, Davies RP, Soar J, Thickett DR. The impact of manual defibrillation technique on no-flow time during simulated cardiopulmonary resuscitation. Resuscitation 2007;73:109-14.
-
(2007)
Resuscitation
, vol.73
, pp. 109-114
-
-
Perkins, G.D.1
Davies, R.P.2
Soar, J.3
Thickett, D.R.4
-
13
-
-
85046499929
-
Paddle size in defibrillation
-
Deakin CD. Paddle size in defibrillation. Br J Anaesth 1998;81:657-8.
-
(1998)
Br J Anaesth
, vol.81
, pp. 657-658
-
-
Deakin, C.D.1
-
14
-
-
26444555575
-
A trial of self-adhesive patch electrodes and hand-held paddle electrodes for external cardioversion of atrial fibrillation (MOBIPAPA)
-
Kirchhof P, Monnig G, Wasmer K, et al. A trial of self-adhesive patch electrodes and hand-held paddle electrodes for external cardioversion of atrial fibrillation (MOBIPAPA). Eur Heart J 2005;26:1292-7.
-
(2005)
Eur Heart J
, vol.26
, pp. 1292-1297
-
-
Kirchhof, P.1
Monnig, G.2
Wasmer, K.3
-
15
-
-
0021855084
-
Experimental evaluation and initial clinical application of new self-adhesive defibrillation electrodes
-
Kerber RE, Martins JB, Ferguson DW, et al. Experimental evaluation and initial clinical application of new self-adhesive defibrillation electrodes. Int J Cardiol 1985;8:57-66.
-
(1985)
Int J Cardiol
, vol.8
, pp. 57-66
-
-
Kerber, R.E.1
Martins, J.B.2
Ferguson, D.W.3
-
16
-
-
0032102690
-
Transthoracic defibrillation: does electrode adhesive pad position alter transthoracic impedance?
-
Garcia LA, Kerber RE. Transthoracic defibrillation: does electrode adhesive pad position alter transthoracic impedance? Resuscitation 1998;37:139-43.
-
(1998)
Resuscitation
, vol.37
, pp. 139-143
-
-
Garcia, L.A.1
Kerber, R.E.2
-
17
-
-
33751256551
-
DC cardioversion of persistent atrial fibrillation: a comparison of two protocols
-
Boodhoo L, Mitchell AR, Bordoli G, Lloyd G, Patel N, Sulke N. DC cardioversion of persistent atrial fibrillation: a comparison of two protocols. Int J Cardiol 2007;114:16-21.
-
(2007)
Int J Cardiol
, vol.114
, pp. 16-21
-
-
Boodhoo, L.1
Mitchell, A.R.2
Bordoli, G.3
Lloyd, G.4
Patel, N.5
Sulke, N.6
-
18
-
-
33847044037
-
Anterior-posterior versus anterior-lateral electrode position for biphasic cardioversion of atrial fibrillation
-
Brazdzionyte J, Babarskiene RM, Stanaitiene G. Anterior-posterior versus anterior-lateral electrode position for biphasic cardioversion of atrial fibrillation. Medicina (Kaunas) 2006;42:994-8.
-
(2006)
Medicina (Kaunas)
, vol.42
, pp. 994-998
-
-
Brazdzionyte, J.1
Babarskiene, R.M.2
Stanaitiene, G.3
-
19
-
-
1242331452
-
External cardioversion in patients with persistent atrial fibrillation: a reappraisal of the effects of electrode pad position and transthoracic impedance on cardioversion success
-
Chen CJ, Guo GB. External cardioversion in patients with persistent atrial fibrillation: a reappraisal of the effects of electrode pad position and transthoracic impedance on cardioversion success. Jpn Heart J 2003;44:921-32.
-
(2003)
Jpn Heart J
, vol.44
, pp. 921-932
-
-
Chen, C.J.1
Guo, G.B.2
-
20
-
-
9944244950
-
External defibrillation in the left lateral position-a comparison of manual paddles with self-adhesive pads
-
Dodd TE, Deakin CD, Petley GW, Clewlow F. External defibrillation in the left lateral position-a comparison of manual paddles with self-adhesive pads. Resuscitation 2004;63:283-6.
-
(2004)
Resuscitation
, vol.63
, pp. 283-236
-
-
Dodd, T.E.1
Deakin, C.D.2
Petley, G.W.3
Clewlow, F.4
-
21
-
-
0019390755
-
Elective cardioversion: influence of paddle-electrode location and size on success rates and energy requirements
-
Kerber RE, Jensen SR, Grayzel J, Kennedy J, Hoyt R. Elective cardioversion: influence of paddle-electrode location and size on success rates and energy requirements. N Engl J Med 1981;305:658-62.
-
(1981)
N Engl J Med
, vol.305
, pp. 658-662
-
-
Kerber, R.E.1
Jensen, S.R.2
Grayzel, J.3
Kennedy, J.4
Hoyt, R.5
-
22
-
-
0033013945
-
Randomised comparison of electrode positions for cardioversion of atrial fibrillation
-
Mathew TP, Moore A, McIntyre M, et al. Randomised comparison of electrode positions for cardioversion of atrial fibrillation. Heart 1999;81:576-9.
-
(1999)
Heart
, vol.81
, pp. 576-579
-
-
Mathew, T.P.1
Moore, A.2
McIntyre, M.3
-
23
-
-
0029065257
-
A three-dimensional finite element model of human transthoracic defibrillation: paddle placement and size
-
Camacho MA, Lehr JL, Eisenberg SR. A three-dimensional finite element model of human transthoracic defibrillation: paddle placement and size. IEEE Trans Biomed Eng 1995;42:572-8.
-
(1995)
IEEE Trans Biomed Eng
, vol.42
, pp. 572-578
-
-
Camacho, M.A.1
Lehr, J.L.2
Eisenberg, S.R.3
-
25
-
-
58149240327
-
Impact of electrical shock waveform and paddle positions on efficacy of direct current cardioversion for atrial fibrillation
-
Stanaitiene G, Babarskiene RM. Impact of electrical shock waveform and paddle positions on efficacy of direct current cardioversion for atrial fibrillation. Medicina (Kaunas) 2008;44:665-72.
-
(2008)
Medicina (Kaunas)
, vol.44
, pp. 665-672
-
-
Stanaitiene, G.1
Babarskiene, R.M.2
-
26
-
-
0032702423
-
External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements
-
Botto GL, Politi A, Bonini W, Broffoni T, Bonatti R. External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements. Heart 1999;82:726-30.
-
(1999)
Heart
, vol.82
, pp. 726-730
-
-
Botto, G.L.1
Politi, A.2
Bonini, W.3
Broffoni, T.4
Bonatti, R.5
-
27
-
-
0037180238
-
Anterior-posterior versus anterior-lateral electrode positions for external cardioversion of atrial fibrillation: a randomised trial
-
Kirchhof P, Eckardt L, Loh P, et al. Anterior-posterior versus anterior-lateral electrode positions for external cardioversion of atrial fibrillation: a randomised trial. Lancet 2002;360:1275-9.
-
(2002)
Lancet
, vol.360
, pp. 1275-1279
-
-
Kirchhof, P.1
Eckardt, L.2
Loh, P.3
-
28
-
-
33748437404
-
Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation
-
Krasteva V, Matveev M, Mudrov N, Prokopova R. Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation. Physiol Meas 2006;27:1009-22.
-
(2006)
Physiol Meas
, vol.27
, pp. 1009-1022
-
-
Krasteva, V.1
Matveev, M.2
Mudrov, N.3
Prokopova, R.4
-
29
-
-
0036027602
-
Does electrode polarity alter the energy requirements for transthoracic biphasic waveform defibrillation? Experimental studies
-
Karlsson G, Zhang Y, Davies LR, Coddington W, Kerber RE. Does electrode polarity alter the energy requirements for transthoracic biphasic waveform defibrillation? Experimental studies. Resuscitation 2001;51:77-81.
-
(2001)
Resuscitation
, vol.51
, pp. 77-81
-
-
Karlsson, G.1
Zhang, Y.2
Davies, L.R.3
Coddington, W.4
Kerber, R.E.5
-
30
-
-
0029239627
-
Optimization of cardiac defibrillation by three-dimensional finite element modeling of the human thorax
-
Panescu D, Webster JG, Tompkins WJ, Stratbucker RA. Optimization of cardiac defibrillation by three-dimensional finite element modeling of the human thorax. IEEE Trans Biomed Eng 1995;42:185-92.
-
(1995)
IEEE Trans Biomed Eng
, vol.42
, pp. 185-192
-
-
Panescu, D.1
Webster, J.G.2
Tompkins, W.J.3
Stratbucker, R.A.4
-
31
-
-
0034664902
-
Randomised comparison of antero-lateral versus antero-posterior paddle positions for DC cardioversion of persistent atrial fibrillation
-
Alp NJ, Rahman S, Bell JA, Shahi M. Randomised comparison of antero-lateral versus antero-posterior paddle positions for DC cardioversion of persistent atrial fibrillation. Int J Cardiol 2000;75:211-6.
-
(2000)
Int J Cardiol
, vol.75
, pp. 211-216
-
-
Alp, N.J.1
Rahman, S.2
Bell, J.A.3
Shahi, M.4
-
32
-
-
0030947831
-
Effect of electrode position and gel-application technique on predicted transcardiac current during transthoracic defibrillation
-
Caterine MR, Yoerger DM, Spencer KT, Miller SG, Kerber RE. Effect of electrode position and gel-application technique on predicted transcardiac current during transthoracic defibrillation. Ann Emerg Med 1997;29:588-95.
-
(1997)
Ann Emerg Med
, vol.29
, pp. 588-595
-
-
Caterine, M.R.1
Yoerger, D.M.2
Spencer, K.T.3
Miller, S.G.4
Kerber, R.E.5
-
33
-
-
0030026251
-
Transthoracic defibrillation: importance of avoiding electrode placement directly on the female breast
-
Pagan-Carlo LA, Spencer KT, Robertson CE, Dengler A, Birkett C, Kerber RE. Transthoracic defibrillation: importance of avoiding electrode placement directly on the female breast. J Am Coll Cardiol 1996;27:449-52.
-
(1996)
J Am Coll Cardiol
, vol.27
, pp. 449-452
-
-
Pagan-Carlo, L.A.1
Spencer, K.T.2
Robertson, C.E.3
Dengler, A.4
Birkett, C.5
Kerber, R.E.6
-
34
-
-
0034283875
-
Effect of shaving the chest of hirsute subjects on transthoracic impedance to self-adhesive defibrillation electrode pads
-
Bissing JW, Kerber RE. Effect of shaving the chest of hirsute subjects on transthoracic impedance to self-adhesive defibrillation electrode pads. Am J Cardiol 2000;86:587-9.
-
(2000)
Am J Cardiol
, vol.86
, pp. 587-589
-
-
Bissing, J.W.1
Kerber, R.E.2
-
35
-
-
0345802613
-
Comparison of the effects of removal of chest hair with not doing so before external defibrillation on transthoracic impedance
-
Sado DM, Deakin CD, Petley GW, Clewlow F. Comparison of the effects of removal of chest hair with not doing so before external defibrillation on transthoracic impedance. Am J Cardiol 2004;93:98-100.
-
(2004)
Am J Cardiol
, vol.93
, pp. 98-100
-
-
Sado, D.M.1
Deakin, C.D.2
Petley, G.W.3
Clewlow, F.4
-
36
-
-
0036842172
-
Defibrillation threshold and cardiac responses using an external biphasic defibrillator with pediatric and adult adhesive patches in pediatric-sized piglets
-
Killingsworth CR, Melnick SB, Chapman FW, et al. Defibrillation threshold and cardiac responses using an external biphasic defibrillator with pediatric and adult adhesive patches in pediatric-sized piglets. Resuscitation 2002;55:177-85.
-
(2002)
Resuscitation
, vol.55
, pp. 177-185
-
-
Killingsworth, C.R.1
Melnick, S.B.2
Chapman, F.W.3
-
37
-
-
0024464088
-
Electrode pad size, transthoracic impedance and success of external ventricular defibrillation
-
Dalzell GW, Cunningham SR, Anderson J, Adgey AA. Electrode pad size, transthoracic impedance and success of external ventricular defibrillation. Am J Cardiol 1989;64:741-4.
-
(1989)
Am J Cardiol
, vol.64
, pp. 741-744
-
-
Dalzell, G.W.1
Cunningham, S.R.2
Anderson, J.3
Adgey, A.A.4
-
38
-
-
0019497010
-
Transthoracic resistance in human defibrillation. Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure
-
Kerber RE, Grayzel J, Hoyt R, Marcus M, Kennedy J. Transthoracic resistance in human defibrillation. Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure. Circulation 1981;63:676-82.
-
(1981)
Circulation
, vol.63
, pp. 676-682
-
-
Kerber, R.E.1
Grayzel, J.2
Hoyt, R.3
Marcus, M.4
Kennedy, J.5
-
39
-
-
0015757856
-
Transthoracic impedance to defibrillator discharge Effect of electrode size and electrode-chest wall interface
-
Connell PN, Ewy GA, Dahl CF, Ewy MD. Transthoracic impedance to defibrillator discharge. Effect of electrode size and electrode-chest wall interface. J Electrocardiol 1973;6:313-20.
-
(1973)
J Electrocardiol
, vol.6
, pp. 313-320
-
-
Connell, P.N.1
Ewy, G.A.2
Dahl, C.F.3
Ewy, M.D.4
-
40
-
-
0016273357
-
Myocardial necrosis from direct current countershock: effect of paddle electrode size and time interval between discharges
-
Dahl CF, Ewy GA, Warner ED, Thomas ED. Myocardial necrosis from direct current countershock: effect of paddle electrode size and time interval between discharges. Circulation 1974;50:956-61.
-
(1974)
Circulation
, vol.50
, pp. 956-961
-
-
Dahl, C.F.1
Ewy, G.A.2
Warner, E.D.3
Thomas, E.D.4
-
42
-
-
0017577668
-
Effectiveness of direct current defibrillation: role of paddle electrode size
-
Thomas ED, Ewy GA, Dahl CF, Ewy MD. Effectiveness of direct current defibrillation: role of paddle electrode size. Am Heart J 1977;93:463-7.
-
(1977)
Am Heart J
, vol.93
, pp. 463-467
-
-
Thomas, E.D.1
Ewy, G.A.2
Dahl, C.F.3
Ewy, M.D.4
-
43
-
-
0028277328
-
Pediatric defibrillation: current flow is improved by using "adult" electrode paddles
-
Atkins DL, Kerber RE. Pediatric defibrillation: current flow is improved by using "adult" electrode paddles. Pediatrics 1994;94:90-3.
-
(1994)
Pediatrics
, vol.94
, pp. 90-93
-
-
Atkins, D.L.1
Kerber, R.E.2
-
44
-
-
0024205987
-
Pediatric defibrillation: importance of paddle size in determining transthoracic impedance
-
Atkins DL, Sirna S, Kieso R, Charbonnier F, Kerber RE. Pediatric defibrillation: importance of paddle size in determining transthoracic impedance. Pediatrics 1988;82:914-8.
-
(1988)
Pediatrics
, vol.82
, pp. 914-918
-
-
Atkins, D.L.1
Sirna, S.2
Kieso, R.3
Charbonnier, F.4
Kerber, R.E.5
-
45
-
-
0028967855
-
Optimal size of self-adhesive preapplied electrode pads in pediatric defibrillation
-
Samson RA, Atkins DL, Kerber RE. Optimal size of self-adhesive preapplied electrode pads in pediatric defibrillation. Am J Cardiol 1995;75: 544-5.
-
(1995)
Am J Cardiol
, vol.75
, pp. 544-545
-
-
Samson, R.A.1
Atkins, D.L.2
Kerber, R.E.3
-
46
-
-
0023815388
-
Factors affecting transthoracic impedance during electrical cardioversion
-
Sirna SJ, Ferguson DW, Charbonnier F, Kerber RE. Factors affecting transthoracic impedance during electrical cardioversion. Am J Cardiol 1988;62: 1048-52.
-
(1988)
Am J Cardiol
, vol.62
, pp. 1048-1052
-
-
Sirna, S.J.1
Ferguson, D.W.2
Charbonnier, F.3
Kerber, R.E.4
-
47
-
-
3242699080
-
Optimisation of electroimpulse therapy of life threatening arrhythmia in patients with ischemic heart disease
-
Razumov KV, Vostrikov VA, Kholin PV. Optimisation of electroimpulse therapy of life threatening arrhythmia in patients with ischemic heart disease. Anesteziol Reanimatol 2003:45-7.
-
(2003)
Anesteziol Reanimatol
, pp. 45-47
-
-
Razumov, K.V.1
Vostrikov, V.A.2
Kholin, P.V.3
-
49
-
-
0019230950
-
Defibrillation recovery curves for different electrode materials
-
Das DP, Webster JG. Defibrillation recovery curves for different electrode materials. IEEE Trans Biomed Eng 1980;27:230-3.
-
(1980)
IEEE Trans Biomed Eng
, vol.27
, pp. 230-233
-
-
Das, D.P.1
Webster, J.G.2
-
50
-
-
0035141401
-
How often should defibrillation pads be changed?: the effect of evaporative drying
-
Deakin CD, Petley GW, Drury NE, Clewlow F. How often should defibrillation pads be changed?: the effect of evaporative drying. Resuscitation 2001;48:157-62.
-
(2001)
Resuscitation
, vol.48
, pp. 157-162
-
-
Deakin, C.D.1
Petley, G.W.2
Drury, N.E.3
Clewlow, F.4
-
51
-
-
43449089813
-
Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation
-
Lloyd MS, Heeke B, Walter PF, Langberg JJ. Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation. Circulation 2008;117:2510-4.
-
(2008)
Circulation
, vol.117
, pp. 2510-2514
-
-
Lloyd, M.S.1
Heeke, B.2
Walter, P.F.3
Langberg, J.J.4
-
52
-
-
0017576410
-
Disposable defibrillator electrodes
-
Ewy GA, Horan WJ, Ewy MD. Disposable defibrillator electrodes. Heart Lung 1977;6:127-30.
-
(1977)
Heart Lung
, vol.6
, pp. 127-130
-
-
Ewy, G.A.1
Horan, W.J.2
Ewy, M.D.3
-
53
-
-
0017836079
-
Impedance to transthoracic direct current discharge: a model for testing interface material
-
Ewy GA, Taren D. Impedance to transthoracic direct current discharge: a model for testing interface material. Med Instrum 1978;12:47-8.
-
(1978)
Med Instrum
, vol.12
, pp. 47-48
-
-
Ewy, G.A.1
Taren, D.2
-
54
-
-
0032426307
-
A comparison of transthoracic impedance using standard defibrillation paddles and self-adhesive defibrillation pads
-
Deakin CD, McLaren RM, Petley GW, Clewlow F, Dalrymple-Hay MJ. A comparison of transthoracic impedance using standard defibrillation paddles and self-adhesive defibrillation pads. Resuscitation 1998;39:43-6.
-
(1998)
Resuscitation
, vol.39
, pp. 43-46
-
-
Deakin, C.D.1
McLaren, R.M.2
Petley, G.W.3
Clewlow, F.4
Dalrymple-Hay, M.J.5
-
55
-
-
18144365202
-
Graber GP. Impedance-gradient electrode reduces skin irritation induced by transthoracic defibrillation
-
Meyer PF, Gadsby PD, Van Sickle D, Schoenlein WE, Foster KS, Graber GP. Impedance-gradient electrode reduces skin irritation induced by transthoracic defibrillation. Med Biol Eng Comput 2005;43:225-9.
-
(2005)
Med Biol Eng Comput
, vol.43
, pp. 225-229
-
-
Meyer, P.F.1
Gadsby, P.D.2
Van Sickle, D.3
Schoenlein, W.E.4
Foster, K.S.5
-
56
-
-
0022398416
-
Defibrillator electrodechest wall coupling agents: influence on transthoracic impedance and shock success
-
Aylward PE, Kieso R, Hite P, Charbonnier F, Kerber RE. Defibrillator electrodechest wall coupling agents: influence on transthoracic impedance and shock success. J Am Coll Cardiol 1985;6:682-6.
-
(1985)
J Am Coll Cardiol
, vol.6
, pp. 682-686
-
-
Aylward, P.E.1
Kieso, R.2
Hite, P.3
Charbonnier, F.4
Kerber, R.E.5
-
57
-
-
0021334055
-
Self-adhesive preapplied electrode pads for defibrillation and cardioversion
-
Kerber RE, Martins JB, Kelly KJ, et al. Self-adhesive preapplied electrode pads for defibrillation and cardioversion. J Am Coll Cardiol 1984;3:815-20.
-
(1984)
J Am Coll Cardiol
, vol.3
, pp. 815-820
-
-
Kerber, R.E.1
Martins, J.B.2
Kelly, K.J.3
-
58
-
-
0024981958
-
A comparative study of contact media for defibrillation
-
Andersen C, Larsen B. A comparative study of contact media for defibrillation. Ugeskr Laeger 1989;151:1987-8.
-
(1989)
Ugeskr Laeger
, vol.151
, pp. 1987-1988
-
-
Andersen, C.1
Larsen, B.2
-
59
-
-
21544447006
-
Attenuated pediatric electrode pads for automated external defibrillator use in children
-
Atkins DL, Jorgenson DB. Attenuated pediatric electrode pads for automated external defibrillator use in children. Resuscitation 2005;66:31-7.
-
(2005)
Resuscitation
, vol.66
, pp. 31-37
-
-
Atkins, D.L.1
Jorgenson, D.B.2
-
60
-
-
2342446537
-
Attenuated adult biphasic shocks compared with weight-based monophasic shocks in a swine model of prolonged pediatric ventricular fibrillation
-
Berg RA, Chapman FW, Berg MD, et al. Attenuated adult biphasic shocks compared with weight-based monophasic shocks in a swine model of prolonged pediatric ventricular fibrillation. Resuscitation 2004;61:189-97.
-
(2004)
Resuscitation
, vol.61
, pp. 189-197
-
-
Berg, R.A.1
Chapman, F.W.2
Berg, M.D.3
-
61
-
-
0345357365
-
Estimation of current density distribution under electrodes for external defibrillation
-
Krasteva VT, Papazov SP. Estimation of current density distribution under electrodes for external defibrillation. Biomed Eng Online 2002;1:7.
-
(2002)
Biomed Eng Online
, vol.1
, pp. 7
-
-
Krasteva, V.T.1
Papazov, S.P.2
-
62
-
-
22744456999
-
Out-of-hospital cardiac arrest rectilinear biphasic to monophasic damped sine defibrillation waveforms with advanced life support intervention trial (ORBIT)
-
Morrison LJ, Dorian P, Long J, et al. Out-of-hospital cardiac arrest rectilinear biphasic to monophasic damped sine defibrillation waveforms with advanced life support intervention trial (ORBIT). Resuscitation 2005;66:149-57.
-
(2005)
Resuscitation
, vol.66
, pp. 149-157
-
-
Morrison, L.J.1
Dorian, P.2
Long, J.3
-
63
-
-
0034633848
-
Multicenter, randomized, controlled trial of 150-J biphasic shocks compared with 200-to 360-J monophasic shocks in the resuscitation of out-of-hospital cardiac arrest victims Optimized Response to Cardiac Arrest (ORCA) Investigators
-
Schneider T, Martens PR, Paschen H, et al. Multicenter, randomized, controlled trial of 150-J biphasic shocks compared with 200-to 360-J monophasic shocks in the resuscitation of out-of-hospital cardiac arrest victims. Optimized Response to Cardiac Arrest (ORCA) Investigators. Circulation 2000;102:1780-7.
-
(2000)
Circulation
, vol.102
, pp. 1780-1787
-
-
Schneider, T.1
Martens, P.R.2
Paschen, H.3
-
64
-
-
0038642762
-
A prospective, randomised and blinded comparison of first shock success of monophasic and biphasic waveforms in out-of-hospital cardiac arrest
-
van Alem AP, Chapman FW, Lank P, Hart AA, Koster RW. A prospective, randomised and blinded comparison of first shock success of monophasic and biphasic waveforms in out-of-hospital cardiac arrest. Resuscitation 2003;58:17-24.
-
(2003)
Resuscitation
, vol.58
, pp. 17-24
-
-
van Alem, A.P.1
Chapman, F.W.2
Lank, P.3
Hart, A.A.4
Koster, R.W.5
-
65
-
-
0242643607
-
Defibrillation waveform and post-shock rhythm in out-of-hospital ventricular fibrillation cardiac arrest
-
Carpenter J, Rea TD, Murray JA, Kudenchuk PJ, Eisenberg MS. Defibrillation waveform and post-shock rhythm in out-of-hospital ventricular fibrillation cardiac arrest. Resuscitation 2003;59:189-96.
-
(2003)
Resuscitation
, vol.59
, pp. 189-196
-
-
Carpenter, J.1
Rea, T.D.2
Murray, J.A.3
Kudenchuk, P.J.4
Eisenberg, M.S.5
-
66
-
-
41649108823
-
Biphasic defibrillation does not improve outcomes compared to monophasic defibrillation in out-of-hospital cardiac arrest
-
Freeman K, Hendey GW, Shalit M, Stroh G. Biphasic defibrillation does not improve outcomes compared to monophasic defibrillation in out-of-hospital cardiac arrest. Prehosp Emerg Care 2008;12:152-6.
-
(2008)
Prehosp Emerg Care
, vol.12
, pp. 152-156
-
-
Freeman, K.1
Hendey, G.W.2
Shalit, M.3
Stroh, G.4
-
67
-
-
0033158078
-
Electrocardiographic evaluation of defibrillation shocks delivered to out-of-hospital sudden cardiac arrest patients
-
Gliner BE, White RD. Electrocardiographic evaluation of defibrillation shocks delivered to out-of-hospital sudden cardiac arrest patients. Resuscitation 1999;41:133-44.
-
(1999)
Resuscitation
, vol.41
, pp. 133-144
-
-
Gliner, B.E.1
White, R.D.2
-
68
-
-
39849097309
-
Increased prevalence of sustained return of spontaneous circulation following transition to biphasic waveform defibrillation
-
Hess EP, Atkinson EJ, White RD. Increased prevalence of sustained return of spontaneous circulation following transition to biphasic waveform defibrillation. Resuscitation 2008;77:39-45.
-
(2008)
Resuscitation
, vol.77
, pp. 39-45
-
-
Hess, E.P.1
Atkinson, E.J.2
White, R.D.3
-
69
-
-
33750808252
-
Transthoracic incremental monophasic versus biphasic defibrillation by emergency responders (TIMBER): a randomized comparison of monophasic with biphasic waveform ascending energy defibrillation for the resuscitation of out-of-hospital cardiac arrest due to ventricular fibrillation
-
Kudenchuk PJ, Cobb LA, Copass MK, Olsufka M, Maynard C, Nichol G. Transthoracic incremental monophasic versus biphasic defibrillation by emergency responders (TIMBER): a randomized comparison of monophasic with biphasic waveform ascending energy defibrillation for the resuscitation of out-of-hospital cardiac arrest due to ventricular fibrillation. Circulation 2006;114:2010-8.
-
(2006)
Circulation
, vol.114
, pp. 2010-2018
-
-
Kudenchuk, P.J.1
Cobb, L.A.2
Copass, M.K.3
Olsufka, M.4
Maynard, C.5
Nichol, G.6
-
70
-
-
67649840232
-
Comparison of neurological outcomes following witnessed out-of-hospital ventricular fibrillation defibrillated with either biphasic or monophasic automated external defibrillators
-
Kajino K, Iwami T, Berg RA, et al. Comparison of neurological outcomes following witnessed out-of-hospital ventricular fibrillation defibrillated with either biphasic or monophasic automated external defibrillators. Emerg Med J 2009;26:492-6.
-
(2009)
Emerg Med J
, vol.26
, pp. 492-496
-
-
Kajino, K.1
Iwami, T.2
Berg, R.A.3
-
71
-
-
0034702730
-
Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care: international consensus on science Part 3 adult basic life support
-
American Heart Association in collaboration with International Liaison Committee on Resuscitation
-
American Heart Association in collaboration with International Liaison Committee on Resuscitation. Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care: international consensus on science, Part 3: adult basic life support. Circulation 2000;102(Suppl. I):I22-59.
-
(2000)
Circulation
, vol.102
, Issue.SUPPL. I
-
-
-
72
-
-
0032406040
-
Encircling overlapping multipulse shock waveforms for transthoracic defibrillation
-
Pagan-Carlo LA, Allan JJ, Spencer KT, Birkett CL, Myers R, Kerber RE. Encircling overlapping multipulse shock waveforms for transthoracic defibrillation. J Am Coll Cardiol 1998;32:2065-71.
-
(1998)
J Am Coll Cardiol
, vol.32
, pp. 2065-2071
-
-
Pagan-Carlo, L.A.1
Allan, J.J.2
Spencer, K.T.3
Birkett, C.L.4
Myers, R.5
Kerber, R.E.6
-
73
-
-
0041626145
-
Triphasic waveforms are superior to biphasic waveforms for transthoracic defibrillation: experimental studies
-
Zhang Y, Ramabadran RS, Boddicker KA, et al. Triphasic waveforms are superior to biphasic waveforms for transthoracic defibrillation: experimental studies. J Am Coll Cardiol 2003;42:568-75.
-
(2003)
J Am Coll Cardiol
, vol.42
, pp. 568-575
-
-
Zhang, Y.1
Ramabadran, R.S.2
Boddicker, K.A.3
-
74
-
-
34247523716
-
BIPHASIC Trial: a randomized comparison of fixed lower versus escalating higher energy levels for defibrillation in out-of-hospital cardiac arrest
-
Stiell IG, Walker RG, Nesbitt LP, et al. BIPHASIC Trial: a randomized comparison of fixed lower versus escalating higher energy levels for defibrillation in out-of-hospital cardiac arrest. Circulation 2007;115:1511-7.
-
(2007)
Circulation
, vol.115
, pp. 1511-1517
-
-
Stiell, I.G.1
Walker, R.G.2
Nesbitt, L.P.3
-
75
-
-
3242732358
-
Efficacy of distinct energy delivery protocols comparing two biphasic defibrillators for cardiac arrest
-
Walsh SJ, McClelland AJ, Owens CG, et al. Efficacy of distinct energy delivery protocols comparing two biphasic defibrillators for cardiac arrest. Am J Cardiol 2004;94:378-80.
-
(2004)
Am J Cardiol
, vol.94
, pp. 378-380
-
-
Walsh, S.J.1
McClelland, A.J.2
Owens, C.G.3
-
76
-
-
38849085165
-
Clinical experience with a low-energy pulsed biphasic waveform in out-of-hospital cardiac arrest
-
Didon JP, Fontaine G, White RD, Jekova I, Schmid JJ, Cansell A. Clinical experience with a low-energy pulsed biphasic waveform in out-of-hospital cardiac arrest. Resuscitation 2008;76:350-3.
-
(2008)
Resuscitation
, vol.76
, pp. 350-353
-
-
Didon, J.P.1
Fontaine, G.2
White, R.D.3
Jekova, I.4
Schmid, J.J.5
Cansell, A.6
-
77
-
-
0019946755
-
Ventricular defibrillation: a comparative trial using 175-J and 320-J shocks
-
Weaver WD, Cobb LA, Copass MK, Hallstrom AP. Ventricular defibrillation: a comparative trial using 175-J and 320-J shocks. N Engl J Med 1982;307:1101-6.
-
(1982)
N Engl J Med
, vol.307
, pp. 1101-1106
-
-
Weaver, W.D.1
Cobb, L.A.2
Copass, M.K.3
Hallstrom, A.P.4
-
78
-
-
0018747534
-
Determinants of ventricular defibrillation in adults
-
Gascho JA, Crampton RS, Cherwek ML, Sipes JN, Hunter FP, O'Brien WM. Determinants of ventricular defibrillation in adults. Circulation 1979;60:231-40.
-
(1979)
Circulation
, vol.60
, pp. 231-240
-
-
Gascho, J.A.1
Crampton, R.S.2
Cherwek, M.L.3
Sipes, J.N.4
Hunter, F.P.5
O'Brien, W.M.6
-
79
-
-
0020512068
-
Determinants of defibrillation: prospective analysis of 183 patients
-
Kerber RE, Jensen SR, Gascho JA, Grayzel J, Hoyt R, Kennedy J. Determinants of defibrillation: prospective analysis of 183 patients. Am J Cardiol 1983;52:739-45.
-
(1983)
Am J Cardiol
, vol.52
, pp. 739-745
-
-
Kerber, R.E.1
Jensen, S.R.2
Gascho, J.A.3
Grayzel, J.4
Hoyt, R.5
Kennedy, J.6
-
80
-
-
1842478223
-
The effects of biphasic waveform design on post-resuscitation myocardial function
-
Tang W, Weil MH, Sun S, et al. The effects of biphasic waveform design on post-resuscitation myocardial function. J Am Coll Cardiol 2004;43:1228-35.
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 1228-1235
-
-
Tang, W.1
Weil, M.H.2
Sun, S.3
-
81
-
-
0030838120
-
High-energy defibrillation increases the severity of postresuscitation myocardial dysfunction
-
Xie J, Weil MH, Sun S, et al. High-energy defibrillation increases the severity of postresuscitation myocardial dysfunction. Circulation 1997;96:683-8.
-
(1997)
Circulation
, vol.96
, pp. 683-688
-
-
Xie, J.1
Weil, M.H.2
Sun, S.3
-
82
-
-
71449125781
-
Comparison of low-energy versus high-energy biphasic defibrillation shocks following prolonged ventricular fibrillation
-
Walcott GP, Melnick SB, Killingsworth CR, Ideker RE. Comparison of low-energy versus high-energy biphasic defibrillation shocks following prolonged ventricular fibrillation. Prehosp Emerg Care 2010;14:62-70.
-
(2010)
Prehosp Emerg Care
, vol.14
, pp. 62-70
-
-
Walcott, G.P.1
Melnick, S.B.2
Killingsworth, C.R.3
Ideker, R.E.4
-
84
-
-
77950959469
-
DEFI 2005 a randomized controlled trial of the effect of automated external defibrillator cardiopulmonary resuscitation protocol on outcome from out-of-hospital cardiac arrest
-
Jost D, Degrange H, Verret C, et al. DEFI 2005: a randomized controlled trial of the effect of automated external defibrillator cardiopulmonary resuscitation protocol on outcome from out-of-hospital cardiac arrest. Circulation 2010;121:1614-22.
-
(2010)
Circulation
, vol.121
, pp. 1614-1622
-
-
Jost, D.1
Degrange, H.2
Verret, C.3
-
85
-
-
40749151501
-
Minimally interrupted cardiac resuscitation by emergency medical services for out-of-hospital cardiac arrest
-
Bobrow BJ, Clark LL, Ewy GA, et al. Minimally interrupted cardiac resuscitation by emergency medical services for out-of-hospital cardiac arrest. JAMA 2008;299:1158-65.
-
(2008)
JAMA
, vol.299
, pp. 1158-1165
-
-
Bobrow, B.J.1
Clark, L.L.2
Ewy, G.A.3
-
86
-
-
33845909870
-
Increasing use of cardiopulmonary resuscitation during out-of-hospital ventricular fibrillation arrest: survival implications of guideline changes
-
Rea TD, Helbock M, Perry S, et al. Increasing use of cardiopulmonary resuscitation during out-of-hospital ventricular fibrillation arrest: survival implications of guideline changes. Circulation 2006;114:2760-5.
-
(2006)
Circulation
, vol.114
, pp. 2760-2765
-
-
Rea, T.D.1
Helbock, M.2
Perry, S.3
-
87
-
-
46749134785
-
Improved survival after an out-of-hospital cardiac arrest using new guidelines
-
Steinmetz J, Barnung S, Nielsen SL, Risom M, Rasmussen LS. Improved survival after an out-of-hospital cardiac arrest using new guidelines. Acta Anaesthesiol Scand 2008;52:908-13.
-
(2008)
Acta Anaesthesiol Scand
, vol.52
, pp. 908-913
-
-
Steinmetz, J.1
Barnung, S.2
Nielsen, S.L.3
Risom, M.4
Rasmussen, L.S.5
-
88
-
-
61449182089
-
Effect of implementation of new resuscitation guidelines on quality of cardiopulmonary resuscitation and survival
-
Olasveengen TM, Vik E, Kuzovlev A, Sunde K. Effect of implementation of new resuscitation guidelines on quality of cardiopulmonary resuscitation and survival. Resuscitation 2009;80:407-11.
-
(2009)
Resuscitation
, vol.80
, pp. 407-411
-
-
Olasveengen, T.M.1
Vik, E.2
Kuzovlev, A.3
Sunde, K.4
-
89
-
-
51749086122
-
A high peak current 150-J fixed-energy defibrillation protocol treats recurrent ventricular fibrillation (VF) as effectively as initial VF
-
Hess EP, Russell JK, Liu PY, White RD. A high peak current 150-J fixed-energy defibrillation protocol treats recurrent ventricular fibrillation (VF) as effectively as initial VF. Resuscitation 2008;79:28-33.
-
(2008)
Resuscitation
, vol.79
, pp. 28-33
-
-
Hess, E.P.1
Russell, J.K.2
Liu, P.Y.3
White, R.D.4
-
90
-
-
77649317657
-
Chest compressions cause recurrence of ventricular fibrillation after the first successful conversion by defibrillation in out-of-hospital cardiac arrest
-
Berdowski J, Tijssen JG, Koster RW. Chest compressions cause recurrence of ventricular fibrillation after the first successful conversion by defibrillation in out-of-hospital cardiac arrest. Circ Arrhythm Electrophysiol; 3:72-8.
-
Circ Arrhythm Electrophysiol
, vol.3
, pp. 72-78
-
-
Berdowski, J.1
Tijssen, J.G.2
Koster, R.W.3
-
91
-
-
34548230590
-
Shock outcome is related to prior rhythm and duration of ventricular fibrillation
-
Eilevstjonn J, Kramer-Johansen J, Sunde K. Shock outcome is related to prior rhythm and duration of ventricular fibrillation. Resuscitation 2007;75: 60-7.
-
(2007)
Resuscitation
, vol.75
, pp. 60-67
-
-
Eilevstjonn, J.1
Kramer-Johansen, J.2
Sunde, K.3
-
92
-
-
77951895178
-
Delaying a shock after takeover from the automated external defibrillator by paramedics is associated with decreased survival
-
Berdowski J, Schulten RJ, Tijssen JG, van Alem AP, Koster RW. Delaying a shock after takeover from the automated external defibrillator by paramedics is associated with decreased survival. Resuscitation 2010;81:287-92.
-
(2010)
Resuscitation
, vol.81
, pp. 287-292
-
-
Berdowski, J.1
Schulten, R.J.2
Tijssen, J.G.3
van Alem, A.P.4
Koster, R.W.5
-
93
-
-
48049110929
-
Recurrent ventricular fibrillation during advanced life support care of patients with prehospital cardiac arrest
-
Koster RW, Walker RG, Chapman FW. Recurrent ventricular fibrillation during advanced life support care of patients with prehospital cardiac arrest. Resuscitation 2008;78:252-7.
-
(2008)
Resuscitation
, vol.78
, pp. 252-257
-
-
Koster, R.W.1
Walker, R.G.2
Chapman, F.W.3
-
94
-
-
84944367520
-
Automatic external defibrillators used by emergency medical technicians: a controlled clinical trial
-
Cummins RO, Eisenberg MS, Litwin PE, Graves JR, Hearne TR, Hallstrom AP. Automatic external defibrillators used by emergency medical technicians: a controlled clinical trial. JAMA 1987;257:1605-10.
-
(1987)
JAMA
, vol.257
, pp. 1605-1660
-
-
Cummins, R.O.1
Eisenberg, M.S.2
Litwin, P.E.3
Graves, J.R.4
Hearne, T.R.5
Hallstrom, A.P.6
-
95
-
-
0022532858
-
Efficacy of an automated external defibrillator in the management of out-of-hospital cardiac arrest: validation of the diagnostic algorithm and initial clinical experience in a rural environment
-
Stults KR, Brown DD, Kerber RE. Efficacy of an automated external defibrillator in the management of out-of-hospital cardiac arrest: validation of the diagnostic algorithm and initial clinical experience in a rural environment. Circulation 1986;73:701-9.
-
(1986)
Circulation
, vol.73
, pp. 701-709
-
-
Stults, K.R.1
Brown, D.D.2
Kerber, R.E.3
-
96
-
-
67650568601
-
Cardiac arrest survival after implementation of automated external defibrillator technology in the in-hospital setting
-
Forcina MS, Farhat AY, O'Neil WW, Haines DE. Cardiac arrest survival after implementation of automated external defibrillator technology in the in-hospital setting. Crit Care Med 2009;37:1229-36.
-
(2009)
Crit Care Med
, vol.37
, pp. 1229-1236
-
-
Forcina, M.S.1
Farhat, A.Y.2
O'Neil, W.W.3
Haines, D.E.4
-
97
-
-
34147135624
-
Pauses in chest compression and inappropriate shocks: a comparison of manual and semi-automatic defibrillation attempts
-
Kramer-Johansen J, Edelson DP, Abella BS, Becker LB, Wik L, Steen PA. Pauses in chest compression and inappropriate shocks: a comparison of manual and semi-automatic defibrillation attempts. Resuscitation 2007;73:212-20.
-
(2007)
Resuscitation
, vol.73
, pp. 212-220
-
-
Kramer-Johansen, J.1
Edelson, D.P.2
Abella, B.S.3
Becker, L.B.4
Wik, L.5
Steen, P.A.6
-
98
-
-
33847363744
-
Comparison of hands-off time during CPR with manual and semi-automatic defibrillation in a manikin model
-
Pytte M, Pedersen TE, Ottem J, Rokvam AS, Sunde K. Comparison of hands-off time during CPR with manual and semi-automatic defibrillation in a manikin model. Resuscitation 2007;73:131-6.
-
(2007)
Resuscitation
, vol.73
, pp. 131-136
-
-
Pytte, M.1
Pedersen, T.E.2
Ottem, J.3
Rokvam, A.S.4
Sunde, K.5
-
99
-
-
0037118665
-
Adverse outcomes of interrupted precordial compression during automated defibrillation
-
Yu T, Weil MH, Tang W, et al. Adverse outcomes of interrupted precordial compression during automated defibrillation. Circulation 2002;106: 368-72.
-
(2002)
Circulation
, vol.106
, pp. 368-372
-
-
Yu, T.1
Weil, M.H.2
Tang, W.3
-
100
-
-
0037076435
-
Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest
-
Eftestol T, Sunde K, Steen PA. Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest. Circulation 2002;105:2270-3.
-
(2002)
Circulation
, vol.105
, pp. 2270-2273
-
-
Eftestol, T.1
Sunde, K.2
Steen, P.A.3
-
101
-
-
33750173272
-
Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest
-
Edelson DP, Abella BS, Kramer-Johansen J, et al. Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. Resuscitation 2006;71:137-45.
-
(2006)
Resuscitation
, vol.71
, pp. 137-145
-
-
Edelson, D.P.1
Abella, B.S.2
Kramer-Johansen, J.3
-
102
-
-
33344454853
-
Post-shock myocardial stunning: a prospective randomised double-blind comparison of monophasic and biphasic waveforms
-
Deakin CD, Ambler JJ. Post-shock myocardial stunning: a prospective randomised double-blind comparison of monophasic and biphasic waveforms. Resuscitation 2006;68:329-33.
-
(2006)
Resuscitation
, vol.68
, pp. 329-333
-
-
Deakin, C.D.1
Ambler, J.J.2
-
103
-
-
0037134946
-
Biphasic versus monophasic shock waveform for conversion of atrial fibrillation: the results of an international randomized, double-blind multicenter trial
-
Page RL, Kerber RE, Russell JK, et al. Biphasic versus monophasic shock waveform for conversion of atrial fibrillation: the results of an international randomized, double-blind multicenter trial. J Am Coll Cardiol 2002;39:1956-63.
-
(2002)
J Am Coll Cardiol
, vol.39
, pp. 1956-1963
-
-
Page, R.L.1
Kerber, R.E.2
Russell, J.K.3
-
104
-
-
20144389343
-
Prospective, randomized comparison of two biphasic waveforms for the efficacy and safety of transthoracic biphasic cardioversion of atrial fibrillation
-
Alatawi F, Gurevitz O, White R. Prospective, randomized comparison of two biphasic waveforms for the efficacy and safety of transthoracic biphasic cardioversion of atrial fibrillation. Heart Rhythm 2005;2:382-7.
-
(2005)
Heart Rhythm
, vol.2
, pp. 382-387
-
-
Alatawi, F.1
Gurevitz, O.2
White, R.3
-
105
-
-
33750171623
-
A randomized controlled trial of efficacy and ST change following use of the Welch-Allyn MRL PIC biphasic waveform versus damped sine monophasic waveform for external DC cardioversion
-
Ambler JJ, Deakin CD. A randomized controlled trial of efficacy and ST change following use of the Welch-Allyn MRL PIC biphasic waveform versus damped sine monophasic waveform for external DC cardioversion. Resuscitation 2006;71:146-51.
-
(2006)
Resuscitation
, vol.71
, pp. 146-151
-
-
Ambler, J.J.1
Deakin, C.D.2
-
106
-
-
0346002956
-
Higher energy monophasic DC cardioversion for persistent atrial fibrillation: is it time to start at 360 joules?
-
Boos C, Thomas MD, Jones A, Clarke E, Wilbourne G, More RS. Higher energy monophasic DC cardioversion for persistent atrial fibrillation: is it time to start at 360 joules? Ann Noninvasive Electrocardiol 2003;8:121-6.
-
(2003)
Ann Noninvasive Electrocardiol
, vol.8
, pp. 121-126
-
-
Boos, C.1
Thomas, M.D.2
Jones, A.3
Clarke, E.4
Wilbourne, G.5
More, R.S.6
-
107
-
-
46249085502
-
Biphasic energy selection for transthoracic cardioversion of atrial fibrillation
-
Glover BM, Walsh SJ, McCann CJ, et al. Biphasic energy selection for transthoracic cardioversion of atrial fibrillation. The BEST AF Trial. Heart 2008;94:884-7.
-
(2008)
The BEST AF Trial. Heart
, vol.94
, pp. 884-887
-
-
Glover, B.M.1
Walsh, S.J.2
McCann, C.J.3
-
108
-
-
0033930581
-
Initial energy for elective external cardioversion of persistent atrial fibrillation
-
Joglar JA, Hamdan MH, Ramaswamy K, et al. Initial energy for elective external cardioversion of persistent atrial fibrillation. Am J Cardiol 2000;86:348-50.
-
(2000)
Am J Cardiol
, vol.86
, pp. 348-350
-
-
Joglar, J.A.1
Hamdan, M.H.2
Ramaswamy, K.3
-
109
-
-
33846969966
-
Monophasic versus biphasic waveform shocks for atrial fibrillation cardioversion in patients with concomitant amiodarone therapy
-
Kawabata VS, Vianna CB, Moretti MA, et al. Monophasic versus biphasic waveform shocks for atrial fibrillation cardioversion in patients with concomitant amiodarone therapy. Europace 2007;9:143-6.
-
(2007)
Europace
, vol.9
, pp. 143-146
-
-
Kawabata, V.S.1
Vianna, C.B.2
Moretti, M.A.3
-
110
-
-
0042510378
-
Biphasic versus monophasic cardioversion in shock-resistant atrial fibrillation
-
Khaykin Y, Newman D, Kowalewski M, Korley V, Dorian P. Biphasic versus monophasic cardioversion in shock-resistant atrial fibrillation. J Cardiovasc Electrophysiol 2003;14:868-72.
-
(2003)
J Cardiovasc Electrophysiol
, vol.14
, pp. 868-872
-
-
Khaykin, Y.1
Newman, D.2
Kowalewski, M.3
Korley, V.4
Dorian, P.5
-
111
-
-
33749333800
-
Comparison the effectiveness of damped sine wave monophasic and rectilinear biphasic shocks in patients with persistent atrial fibrillation
-
Kmec J. Comparison the effectiveness of damped sine wave monophasic and rectilinear biphasic shocks in patients with persistent atrial fibrillation. Kardiologia 2006;15:265-78.
-
(2006)
Kardiologia
, vol.15
, pp. 265-278
-
-
Kmec, J.1
-
112
-
-
3042851661
-
A randomized trial comparing monophasic and biphasic waveform shocks for external cardioversion of atrial fibrillation
-
Koster RW, Dorian P, Chapman FW, Schmitt PW, O'Grady SG, Walker RG. A randomized trial comparing monophasic and biphasic waveform shocks for external cardioversion of atrial fibrillation. Am Heart J 2004;147:e20.
-
(2004)
Am Heart J
, vol.147
-
-
Koster, R.W.1
Dorian, P.2
Chapman, F.W.3
Schmitt, P.W.4
O'Grady, S.G.5
Walker, R.G.6
-
113
-
-
0141483337
-
Efficacy and impact of monophasic versus biphasic countershocks for transthoracic cardioversion of persistent atrial fibrillation
-
Marinsek M, Larkin GL, Zohar P, et al. Efficacy and impact of monophasic versus biphasic countershocks for transthoracic cardioversion of persistent atrial fibrillation. Am J Cardiol 2003;92:988-91.
-
(2003)
Am J Cardiol
, vol.92
, pp. 988-991
-
-
Marinsek, M.1
Larkin, G.L.2
Zohar, P.3
-
114
-
-
0034696653
-
Transthoracic cardioversion of atrial fibrillation: comparison of rectilinear biphasic versus damped sine wave monophasic shocks
-
Mittal S, Ayati S, Stein KM, et al. Transthoracic cardioversion of atrial fibrillation: comparison of rectilinear biphasic versus damped sine wave monophasic shocks. Circulation 2000;101:1282-7.
-
(2000)
Circulation
, vol.101
, pp. 1282-1287
-
-
Mittal, S.1
Ayati, S.2
Stein, K.M.3
-
115
-
-
48249148346
-
Biphasic versus monophasic shock for external cardioversion of atrial flutter: a prospective, randomized trial
-
Mortensen K, Risius T, Schwemer TF, et al. Biphasic versus monophasic shock for external cardioversion of atrial flutter: a prospective, randomized trial. Cardiology 2008;111:57-62.
-
(2008)
Cardiology
, vol.111
, pp. 57-62
-
-
Mortensen, K.1
Risius, T.2
Schwemer, T.F.3
-
116
-
-
0033008506
-
A comparison of 50-J versus 100-J shocks for direct-current cardioversion of atrial flutter
-
Pinski SL, Sgarbossa EB, Ching E, Trohman RG. A comparison of 50-J versus 100-J shocks for direct-current cardioversion of atrial flutter. Am Heart J 1999;137:439-42.
-
(1999)
Am Heart J
, vol.137
, pp. 439-442
-
-
Pinski, S.L.1
Sgarbossa, E.B.2
Ching, E.3
Trohman, R.G.4
-
117
-
-
0037108209
-
Efficacy of biphasic waveform cardioversion for atrial fibrillation and atrial flutter compared with conventional monophasic waveforms
-
Ermis C, Zhu AX, Sinha S, et al. Efficacy of biphasic waveform cardioversion for atrial fibrillation and atrial flutter compared with conventional monophasic waveforms. Am J Cardiol 2002;90:891-2.
-
(2002)
Am J Cardiol
, vol.90
, pp. 891-892
-
-
Ermis, C.1
Zhu, A.X.2
Sinha, S.3
-
118
-
-
13944262527
-
Efficacy of transthoracic cardioversion of atrial fibrillation using a biphasic, truncated exponential shock waveform at variable initial shock energies
-
Rashba EJ, Gold MR, Crawford FA, Leman RB, Peters RW, Shorofsky SR. Efficacy of transthoracic cardioversion of atrial fibrillation using a biphasic, truncated exponential shock waveform at variable initial shock energies. Am J Cardiol 2004;94:1572-4.
-
(2004)
Am J Cardiol
, vol.94
, pp. 1572-1574
-
-
Rashba, E.J.1
Gold, M.R.2
Crawford, F.A.3
Leman, R.B.4
Peters, R.W.5
Shorofsky, S.R.6
-
119
-
-
33751217742
-
A randomised controlled trial of the effect of biphasic or monophasic waveform on the incidence and severity of cutaneous burns following external direct current cardioversion
-
Ambler JJ, Deakin CD. A randomised controlled trial of the effect of biphasic or monophasic waveform on the incidence and severity of cutaneous burns following external direct current cardioversion. Resuscitation 2006;71:293-300.
-
(2006)
Resuscitation
, vol.71
, pp. 293-300
-
-
Ambler, J.J.1
Deakin, C.D.2
-
120
-
-
0023820718
-
Prehospital external cardiac pacing: a prospective, controlled clinical trial
-
Barthell E, Troiano P, Olson D, Stueven HA, Hendley G. Prehospital external cardiac pacing: a prospective, controlled clinical trial. Ann Emerg Med 1988;17:1221-6.
-
(1988)
Ann Emerg Med
, vol.17
, pp. 1221-1226
-
-
Barthell, E.1
Troiano, P.2
Olson, D.3
Stueven, H.A.4
Hendley, G.5
-
121
-
-
0027197066
-
Out-of-hospital transcutaneous pacing by emergency medical technicians in patients with asystolic cardiac arrest
-
Cummins RO, Graves JR, Larsen MP, et al. Out-of-hospital transcutaneous pacing by emergency medical technicians in patients with asystolic cardiac arrest. N Engl J Med 1993;328:1377-82.
-
(1993)
N Engl J Med
, vol.328
, pp. 1377-1382
-
-
Cummins, R.O.1
Graves, J.R.2
Larsen, M.P.3
-
122
-
-
0023472540
-
Prehospital trial of emergency transcutaneous cardiac pacing
-
Hedges JR, Syverud SA, Dalsey WC, Feero S, Easter R, Shultz B. Prehospital trial of emergency transcutaneous cardiac pacing. Circulation 1987;76:1337-43.
-
(1987)
Circulation
, vol.76
, pp. 1337-1343
-
-
Hedges, J.R.1
Syverud, S.A.2
Dalsey, W.C.3
Feero, S.4
Easter, R.5
Shultz, B.6
-
123
-
-
0021949664
-
Immediate transthoracic pacing for cardiac asystole in an emergency department setting
-
White JD, Brown CG. Immediate transthoracic pacing for cardiac asystole in an emergency department setting. Am J Emerg Med 1985;3:125-8.
-
(1985)
Am J Emerg Med
, vol.3
, pp. 125-128
-
-
White, J.D.1
Brown, C.G.2
-
124
-
-
0036157411
-
Effect of three emergency pacing modalities on cardiac output in cardiac arrest due to ventricular asystole
-
Chan L, Reid C, Taylor B. Effect of three emergency pacing modalities on cardiac output in cardiac arrest due to ventricular asystole. Resuscitation 2002;52:117-9.
-
(2002)
Resuscitation
, vol.52
, pp. 117-119
-
-
Chan, L.1
Reid, C.2
Taylor, B.3
-
125
-
-
0029950021
-
Ventricular standstill and cardiac percussion
-
Dowdle JR. Ventricular standstill and cardiac percussion. Resuscitation 1996;32:31-2.
-
(1996)
Resuscitation
, vol.32
, pp. 31-32
-
-
Dowdle, J.R.1
-
126
-
-
26444540412
-
Percussion pacing in a three-year-old girl with complete heart block during cardiac catheterization
-
Eich C, Bleckmann A, Paul T. Percussion pacing in a three-year-old girl with complete heart block during cardiac catheterization. Br J Anaesth 2005;95:465-7.
-
(2005)
Br J Anaesth
, vol.95
, pp. 465-467
-
-
Eich, C.1
Bleckmann, A.2
Paul, T.3
-
127
-
-
0023356731
-
Fist pacing, a forgotten procedure in bradyasystolic cardiac arrest
-
Iseri LT, Allen BJ, Baron K, Brodsky MA. Fist pacing, a forgotten procedure in bradyasystolic cardiac arrest. Am Heart J 1987;113:1545-50.
-
(1987)
Am Heart J
, vol.113
, pp. 1545-1550
-
-
Iseri, L.T.1
Allen, B.J.2
Baron, K.3
Brodsky, M.A.4
-
128
-
-
0028872159
-
Manual external (fist) pacing during high-degree atrioventricular block: a lifesaving intervention
-
Tucker KJ, Shaburihvili TS, Gedevanishvili AT. Manual external (fist) pacing during high-degree atrioventricular block: a lifesaving intervention. Am J Emerg Med 1995;13:53-4.
-
(1995)
Am J Emerg Med
, vol.13
, pp. 53-54
-
-
Tucker, K.J.1
Shaburihvili, T.S.2
Gedevanishvili, A.T.3
-
129
-
-
34248209491
-
Percussion pacing-an almost forgotten procedure for haemodynamically unstable bradycardias? A report of three case studies and review of the literature
-
Eich C, Bleckmann A, Schwarz SK. Percussion pacing-an almost forgotten procedure for haemodynamically unstable bradycardias? A report of three case studies and review of the literature. Br J Anaesth 2007;98:429-33.
-
(2007)
Br J Anaesth
, vol.98
, pp. 429-433
-
-
Eich, C.1
Bleckmann, A.2
Schwarz, S.K.3
-
130
-
-
0017808227
-
The manual extrathoracal stimulation of the heart Technique and effect of the precordial thump (author's transl)
-
Zeh E, Rahner E. The manual extrathoracal stimulation of the heart. Technique and effect of the precordial thump (author's transl). Z Kardiol 1978;67:299-304.
-
(1978)
Z Kardiol
, vol.67
, pp. 299-304
-
-
Zeh, E.1
Rahner, E.2
-
131
-
-
34547791825
-
External cardioversion of atrial fibrillation in patients with implanted pacemaker or cardioverter-defibrillator systems: a randomized comparison of monophasic and biphasic shock energy application
-
Manegold JC, Israel CW, Ehrlich JR, et al. External cardioversion of atrial fibrillation in patients with implanted pacemaker or cardioverter-defibrillator systems: a randomized comparison of monophasic and biphasic shock energy application. Eur Heart J 2007;28:1731-8.
-
(2007)
Eur Heart J
, vol.28
, pp. 1731-1738
-
-
Manegold, J.C.1
Israel, C.W.2
Ehrlich, J.R.3
-
132
-
-
0020133091
-
Pacemaker damage due to external countershock in patients with implanted cardiac pacemakers
-
Alferness CA. Pacemaker damage due to external countershock in patients with implanted cardiac pacemakers. Pacing Clin Electrophysiol 1982;5:457-8.
-
(1982)
Pacing Clin Electrophysiol
, vol.5
, pp. 457-458
-
-
Alferness, C.A.1
-
133
-
-
0028845805
-
Semiautomatic external defibrillation and implanted cardiac pacemakers: understanding the interactions during resuscitation
-
Monsieurs KG, Conraads VM, Goethals MP, Snoeck JP, Bossaert LL. Semiautomatic external defibrillation and implanted cardiac pacemakers: understanding the interactions during resuscitation. Resuscitation 1995;30:127-31.
-
(1995)
Resuscitation
, vol.30
, pp. 127-131
-
-
Monsieurs, K.G.1
Conraads, V.M.2
Goethals, M.P.3
Snoeck, J.P.4
Bossaert, L.L.5
-
134
-
-
0021929825
-
Amplitude of ventricular fibrillation waveform and outcome after cardiac arrest
-
Weaver WD, Cobb LA, Dennis D, Ray R, Hallstrom AP, Copass MK. Amplitude of ventricular fibrillation waveform and outcome after cardiac arrest. Ann Intern Med 1985;102:53-5.
-
(1985)
Ann Intern Med
, vol.102
, pp. 53-55
-
-
Weaver, W.D.1
Cobb, L.A.2
Dennis, D.3
Ray, R.4
Hallstrom, A.P.5
Copass, M.K.6
-
135
-
-
11144324467
-
A probabilistic neural network as the predictive classifier of out-of-hospital defibrillation outcomes
-
Yang Z, Lu W, Harrison RG, Eftestol T, Steen PA. A probabilistic neural network as the predictive classifier of out-of-hospital defibrillation outcomes. Resuscitation 2005;64:31-6.
-
(2005)
Resuscitation
, vol.64
, pp. 31-36
-
-
Yang, Z.1
Lu, W.2
Harrison, R.G.3
Eftestol, T.4
Steen, P.A.5
-
136
-
-
48049093031
-
Shock outcome prediction before and after CPR: a comparative study of manual and automated active compression-decompression CPR
-
Box MS, Watson JN, Addison PS, Clegg GR, Robertson CE. Shock outcome prediction before and after CPR: a comparative study of manual and automated active compression-decompression CPR. Resuscitation 2008;78:265-74.
-
(2008)
Resuscitation
, vol.78
, pp. 265-274
-
-
Box, M.S.1
Watson, J.N.2
Addison, P.S.3
Clegg, G.R.4
Robertson, C.E.5
-
137
-
-
0027396479
-
Physiologic measurement of the ventricular fibrillation ECG signal: estimating the duration of ventricular fibrillation
-
Brown CG, Dzwonczyk R, Martin DR. Physiologic measurement of the ventricular fibrillation ECG signal: estimating the duration of ventricular fibrillation. Ann Emerg Med 1993;22:70-4.
-
(1993)
Ann Emerg Med
, vol.22
, pp. 70-74
-
-
Brown, C.G.1
Dzwonczyk, R.2
Martin, D.R.3
-
138
-
-
0035957268
-
Scaling exponent predicts defibrillation success for out-of-hospital ventricular fibrillation cardiac arrest
-
Callaway CW, Sherman LD, Mosesso Jr VN, Dietrich TJ, Holt E, Clarkson MC. Scaling exponent predicts defibrillation success for out-of-hospital ventricular fibrillation cardiac arrest. Circulation 2001;103:1656-61.
-
(2001)
Circulation
, vol.103
, pp. 1656-1661
-
-
Callaway, C.W.1
Sherman, L.D.2
Mosesso Jr, V.N.3
Dietrich, T.J.4
Holt, E.5
Clarkson, M.C.6
-
139
-
-
0034718516
-
Predicting outcome of defibrillation by spectral characterization and nonparametric classification of ventricular fibrillation in patients with out-of-hospital cardiac arrest
-
Eftestol T, Sunde K, Aase SO, Husoy JH, Steen PA. Predicting outcome of defibrillation by spectral characterization and nonparametric classification of ventricular fibrillation in patients with out-of-hospital cardiac arrest. Circulation 2000;102:1523-9.
-
(2000)
Circulation
, vol.102
, pp. 1523-1529
-
-
Eftestol, T.1
Sunde, K.2
Aase, S.O.3
Husoy, J.H.4
Steen, P.A.5
-
140
-
-
3042715246
-
Effects of cardiopulmonary resuscitation on predictors of ventricular fibrillation defibrillation success during out-of-hospital cardiac arrest
-
Eftestol T, Wik L, Sunde K, Steen PA. Effects of cardiopulmonary resuscitation on predictors of ventricular fibrillation defibrillation success during out-of-hospital cardiac arrest. Circulation 2004;110:10-5.
-
(2004)
Circulation
, vol.110
, pp. 10-15
-
-
Eftestol, T.1
Wik, L.2
Sunde, K.3
Steen, P.A.4
-
141
-
-
25844453881
-
Independent evaluation of a defibrillation outcome predictor for out-of-hospital cardiac arrested patients
-
Eftestol T, Losert H, Kramer-Johansen J, Wik L, Sterz F, Steen PA. Independent evaluation of a defibrillation outcome predictor for out-of-hospital cardiac arrested patients. Resuscitation 2005;67:55-61.
-
(2005)
Resuscitation
, vol.67
, pp. 55-61
-
-
Eftestol, T.1
Losert, H.2
Kramer-Johansen, J.3
Wik, L.4
Sterz, F.5
Steen, P.A.6
-
142
-
-
38049030315
-
Identifying approaches to improve the accuracy of shock outcome prediction for out-of-hospital cardiac arrest
-
Gundersen K, Kvaloy JT, Kramer-Johansen J, Eftestol T. Identifying approaches to improve the accuracy of shock outcome prediction for out-of-hospital cardiac arrest. Resuscitation 2008;76:279-84.
-
(2008)
Resuscitation
, vol.76
, pp. 279-284
-
-
Gundersen, K.1
Kvaloy, J.T.2
Kramer-Johansen, J.3
Eftestol, T.4
-
143
-
-
44749090080
-
Using within-patient correlation to improve the accuracy of shock outcome prediction for cardiac arrest
-
Gundersen K, Kvaloy JT, Kramer-Johansen J, Olasveengen TM, Eilevstjonn J, Eftestol T. Using within-patient correlation to improve the accuracy of shock outcome prediction for cardiac arrest. Resuscitation 2008;78:46-51.
-
(2008)
Resuscitation
, vol.78
, pp. 46-51
-
-
Gundersen, K.1
Kvaloy, J.T.2
Kramer-Johansen, J.3
Olasveengen, T.M.4
Eilevstjonn, J.5
Eftestol, T.6
-
144
-
-
63749115175
-
Development of the probability of return of spontaneous circulation in intervals without chest compressions during out-of-hospital cardiac arrest: an observational study
-
Gundersen K, Kvaloy JT, Kramer-Johansen J, Steen PA, Eftestol T. Development of the probability of return of spontaneous circulation in intervals without chest compressions during out-of-hospital cardiac arrest: an observational study. BMC Med 2009;7:6.
-
(2009)
BMC Med
, vol.7
, pp. 6
-
-
Gundersen, K.1
Kvaloy, J.T.2
Kramer-Johansen, J.3
Steen, P.A.4
Eftestol, T.5
-
145
-
-
58149388019
-
Chest compression quality variables influencing the temporal development of ROSC-predictors calculated from the ECG during VF
-
Gundersen K, Nysaether J, Kvaloy JT, Kramer-Johansen J, Eftestol T. Chest compression quality variables influencing the temporal development of ROSC-predictors calculated from the ECG during VF. Resuscitation 2009;80:177-82.
-
(2009)
Resuscitation
, vol.80
, pp. 177-182
-
-
Gundersen, K.1
Nysaether, J.2
Kvaloy, J.T.3
Kramer-Johansen, J.4
Eftestol, T.5
-
146
-
-
7044235705
-
Defibrillation shock success estimation by a set of six parameters derived from the electrocardiogram
-
Jekova I, Mougeolle F, Valance A. Defibrillation shock success estimation by a set of six parameters derived from the electrocardiogram. Physiol Meas 2004;25:1179-88.
-
(2004)
Physiol Meas
, vol.25
, pp. 1179-1188
-
-
Jekova, I.1
Mougeolle, F.2
Valance, A.3
-
147
-
-
37549012158
-
Electrocardiogram waveforms for monitoring effectiveness of chest compression during cardiopulmonary resuscitation
-
Li Y, Ristagno G, Bisera J, Tang W, Deng Q, Weil MH. Electrocardiogram waveforms for monitoring effectiveness of chest compression during cardiopulmonary resuscitation. Crit Care Med 2008;36:211-5.
-
(2008)
Crit Care Med
, vol.36
, pp. 211-215
-
-
Li, Y.1
Ristagno, G.2
Bisera, J.3
Tang, W.4
Deng, Q.5
Weil, M.H.6
-
148
-
-
34147189200
-
Prediction of countershock success using single features from multiple ventricular fibrillation frequency bands and feature combinations using neural networks
-
Neurauter A, Eftestol T, Kramer-Johansen J, et al. Prediction of countershock success using single features from multiple ventricular fibrillation frequency bands and feature combinations using neural networks. Resuscitation 2007;73:253-63.
-
(2007)
Resuscitation
, vol.73
, pp. 253-263
-
-
Neurauter, A.1
Eftestol, T.2
Kramer-Johansen, J.3
-
149
-
-
61449259768
-
Acute ischemic heart disease alters ventricular fibrillation waveform characteristics in out-of hospital cardiac arrest
-
Olasveengen TM, Eftestol T, Gundersen K, Wik L, Sunde K. Acute ischemic heart disease alters ventricular fibrillation waveform characteristics in out-of hospital cardiac arrest. Resuscitation 2009;80:412-7.
-
(2009)
Resuscitation
, vol.80
, pp. 412-417
-
-
Olasveengen, T.M.1
Eftestol, T.2
Gundersen, K.3
Wik, L.4
Sunde, K.5
-
150
-
-
38949097068
-
Prediction of successful defibrillation in human victims of out-of-hospital cardiac arrest: a retrospective electrocardiographic analysis
-
Ristagno G, Gullo A, Berlot G, Lucangelo U, Geheb E, Bisera J. Prediction of successful defibrillation in human victims of out-of-hospital cardiac arrest: a retrospective electrocardiographic analysis. Anaesth Intensive Care 2008;36:46-50.
-
(2008)
Anaesth Intensive Care
, vol.36
, pp. 46-50
-
-
Ristagno, G.1
Gullo, A.2
Berlot, G.3
Lucangelo, U.4
Geheb, E.5
Bisera, J.6
-
151
-
-
33749440039
-
Off-label use: an industry perspective on expanding use beyond approved indications
-
Russell ME, Friedman MI, Mascioli SR, Stolz LE. Off-label use: an industry perspective on expanding use beyond approved indications. J Interv Cardiol 2006;19:432-8.
-
(2006)
J Interv Cardiol
, vol.19
, pp. 432-438
-
-
Russell, M.E.1
Friedman, M.I.2
Mascioli, S.R.3
Stolz, L.E.4
-
152
-
-
33845447517
-
Outcome prediction for guidance of initial resuscitation protocol: shock first or CPR first
-
Snyder DE, White RD, Jorgenson DB. Outcome prediction for guidance of initial resuscitation protocol: shock first or CPR first. Resuscitation 2007;72: 45-51.
-
(2007)
Resuscitation
, vol.72
, pp. 45-51
-
-
Snyder, D.E.1
White, R.D.2
Jorgenson, D.B.3
-
153
-
-
9944256106
-
Improved prediction of defibrillation success for out-of-hospital VF cardiac arrest using wavelet transform methods
-
Watson JN, Uchaipichat N, Addison PS, et al. Improved prediction of defibrillation success for out-of-hospital VF cardiac arrest using wavelet transform methods. Resuscitation 2004;63:269-75.
-
(2004)
Resuscitation
, vol.63
, pp. 269-275
-
-
Watson, J.N.1
Uchaipichat, N.2
Addison, P.S.3
-
154
-
-
30144444784
-
Practical issues in the evaluation of methods for the prediction of shock outcome success in out-of-hospital cardiac arrest patients
-
Watson JN, Addison PS, Clegg GR, Steen PA, Robertson CE. Practical issues in the evaluation of methods for the prediction of shock outcome success in out-of-hospital cardiac arrest patients. Resuscitation 2006;68:51-9.
-
(2006)
Resuscitation
, vol.68
, pp. 51-59
-
-
Watson, J.N.1
Addison, P.S.2
Clegg, G.R.3
Steen, P.A.4
Robertson, C.E.5
-
155
-
-
33847060929
-
Irregularity test for very short electrocardiogram (ECG) signals as a method for predicting a successful defibrillation in patients with ventricular fibrillation
-
Jagric T, Marhl M, Stajer D, Kocjancic ST, Podbregar M, Perc M. Irregularity test for very short electrocardiogram (ECG) signals as a method for predicting a successful defibrillation in patients with ventricular fibrillation. Transl Res 2007;149:145-51.
-
(2007)
Transl Res
, vol.149
, pp. 145-151
-
-
Jagric, T.1
Marhl, M.2
Stajer, D.3
Kocjancic, S.T.4
Podbregar, M.5
Perc, M.6
-
156
-
-
0030901085
-
Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans
-
Strohmenger HU, Lindner KH, Brown CG. Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans. Chest 1997;111:584-9.
-
(1997)
Chest
, vol.111
, pp. 584-589
-
-
Strohmenger, H.U.1
Lindner, K.H.2
Brown, C.G.3
-
157
-
-
0242643601
-
Immediate defibrillation versus interventions first in a swine model of prolonged ventricular fibrillation
-
Menegazzi JJ, Wang HE, Lightfoot CB, et al. Immediate defibrillation versus interventions first in a swine model of prolonged ventricular fibrillation. Resuscitation 2003;59:261-70.
-
(2003)
Resuscitation
, vol.59
, pp. 261-270
-
-
Menegazzi, J.J.1
Wang, H.E.2
Lightfoot, C.B.3
-
158
-
-
0036712855
-
The prediction of defibrillation outcome using a new combination of mean frequency and amplitude in porcine models of cardiac arrest
-
table of contents
-
Amann A, Rheinberger K, Achleitner U, et al. The prediction of defibrillation outcome using a new combination of mean frequency and amplitude in porcine models of cardiac arrest. Anesth Analg 2002;95:716-22, table of contents.
-
(2002)
Anesth Analg
, vol.95
, pp. 716-722
-
-
Amann, A.1
Rheinberger, K.2
Achleitner, U.3
-
160
-
-
33646146389
-
The characteristics of postcountershock pulseless electrical activity may indicate the outcome of CPR
-
Fang X, Tang W, Sun S, Wang J, Huang L, Weil MH. The characteristics of postcountershock pulseless electrical activity may indicate the outcome of CPR. Resuscitation 2006;69:303-9.
-
(2006)
Resuscitation
, vol.69
, pp. 303-309
-
-
Fang, X.1
Tang, W.2
Sun, S.3
Wang, J.4
Huang, L.5
Weil, M.H.6
-
161
-
-
0034802232
-
Fibrillation power, an alternative method of ECG spectral analysis for prediction of countershock success in a porcine model of ventricular fibrillation
-
Hamprecht FA, Achleitner U, Krismer AC, et al. Fibrillation power, an alternative method of ECG spectral analysis for prediction of countershock success in a porcine model of ventricular fibrillation. Resuscitation 2001;50:287-96.
-
(2001)
Resuscitation
, vol.50
, pp. 287-296
-
-
Hamprecht, F.A.1
Achleitner, U.2
Krismer, A.C.3
-
162
-
-
34247142936
-
Ventricular fibrillation frequency characteristics are altered in acute myocardial infarction
-
Indik JH, Donnerstein RL, Berg RA, Hilwig RW, Berg MD, Kern KB. Ventricular fibrillation frequency characteristics are altered in acute myocardial infarction. Crit Care Med 2007;35:1133-8.
-
(2007)
Crit Care Med
, vol.35
, pp. 1133-1138
-
-
Indik, J.H.1
Donnerstein, R.L.2
Berg, R.A.3
Hilwig, R.W.4
Berg, M.D.5
Kern, K.B.6
-
163
-
-
0037651279
-
Optimal timing for electrical defibrillation after prolonged untreated ventricular fibrillation
-
Kolarova J, Ayoub IM, Yi Z, Gazmuri RJ. Optimal timing for electrical defibrillation after prolonged untreated ventricular fibrillation. Crit Care Med 2003;31:2022-8.
-
(2003)
Crit Care Med
, vol.31
, pp. 2022-2028
-
-
Kolarova, J.1
Ayoub, I.M.2
Yi, Z.3
Gazmuri, R.J.4
-
164
-
-
0042347730
-
Dynamic nature of electrocardiographic waveform predicts rescue shock outcome in porcine ventricular fibrillation
-
Lightfoot CB, Nremt P, Callaway CW, et al. Dynamic nature of electrocardiographic waveform predicts rescue shock outcome in porcine ventricular fibrillation. Ann Emerg Med 2003;42:230-41.
-
(2003)
Ann Emerg Med
, vol.42
, pp. 230-241
-
-
Lightfoot, C.B.1
Nremt, P.2
Callaway, C.W.3
-
165
-
-
0035679842
-
Optimizing timing of ventricular defibrillation
-
Marn-Pernat A, Weil MH, Tang W, Pernat A, Bisera J. Optimizing timing of ventricular defibrillation. Crit Care Med 2001;29:2360-5.
-
(2001)
Crit Care Med
, vol.29
, pp. 2360-2365
-
-
Marn-Pernat, A.1
Weil, M.H.2
Tang, W.3
Pernat, A.4
Bisera, J.5
-
166
-
-
0033711139
-
Electrocardiographic waveform analysis for predicting the success of defibrillation
-
Povoas HP, Bisera J. Electrocardiographic waveform analysis for predicting the success of defibrillation. Crit Care Med 2000;28:N210-1.
-
(2000)
Crit Care Med
, vol.28
-
-
Povoas, H.P.1
Bisera, J.2
-
167
-
-
1342321914
-
Angular velocity: a new method to improve prediction of ventricular fibrillation duration
-
Sherman LD, Flagg A, Callaway CW, Menegazzi JJ, Hsieh M. Angular velocity: a new method to improve prediction of ventricular fibrillation duration. Resuscitation 2004;60:79-90.
-
(2004)
Resuscitation
, vol.60
, pp. 79-90
-
-
Sherman, L.D.1
Flagg, A.2
Callaway, C.W.3
Menegazzi, J.J.4
Hsieh, M.5
-
168
-
-
33646894127
-
The frequency ratio: an improved method to estimate ventricular fibrillation duration based on Fourier analysis of the waveform
-
Sherman LD. The frequency ratio: an improved method to estimate ventricular fibrillation duration based on Fourier analysis of the waveform. Resuscitation 2006;69:479-86.
-
(2006)
Resuscitation
, vol.69
, pp. 479-486
-
-
Sherman, L.D.1
-
169
-
-
48149085562
-
Logarithm of the absolute correlations of the ECG waveform estimates duration of ventricular fibrillation and predicts successful defibrillation
-
Sherman LD, Rea TD, Waters JD, Menegazzi JJ, Callaway CW. Logarithm of the absolute correlations of the ECG waveform estimates duration of ventricular fibrillation and predicts successful defibrillation. Resuscitation 2008;78:346-54.
-
(2008)
Resuscitation
, vol.78
, pp. 346-354
-
-
Sherman, L.D.1
Rea, T.D.2
Waters, J.D.3
Menegazzi, J.J.4
Callaway, C.W.5
-
170
-
-
7244231058
-
Amplitude spectrum area: measuring the probability of successful defibrillation as applied to human data
-
Young C, Bisera J, Gehman S, Snyder D, Tang W, Weil MH. Amplitude spectrum area: measuring the probability of successful defibrillation as applied to human data. Crit Care Med 2004;32:S356-8.
-
(2004)
Crit Care Med
, vol.32
-
-
Young, C.1
Bisera, J.2
Gehman, S.3
Snyder, D.4
Tang, W.5
Weil, M.H.6
-
171
-
-
9244245266
-
Ventricular fibrillation median frequency may not be useful for monitoring during cardiac arrest treated with endothelin-1 or epinephrine
-
table of contents
-
Holzer M, Behringer W, Sterz F, et al. Ventricular fibrillation median frequency may not be useful for monitoring during cardiac arrest treated with endothelin-1 or epinephrine. Anesth Analg 2004;99:1787-93, table of contents.
-
(2004)
Anesth Analg
, vol.99
, pp. 1787-1793
-
-
Holzer, M.1
Behringer, W.2
Sterz, F.3
-
172
-
-
0015501339
-
Potential fire hazard in defibrillation
-
Miller PH. Potential fire hazard in defibrillation. JAMA 1972; 221:192.
-
(1972)
JAMA
, vol.221
, pp. 192
-
-
Miller, P.H.1
-
173
-
-
0042204625
-
Defibrillation in oxygen-enriched environments, [hazard]
-
ECRI
-
ECRI. Defibrillation in oxygen-enriched environments [hazard]. Health Devices 1987;16:113-4.
-
(1987)
Health Devices
, vol.16
, pp. 113-114
-
-
-
174
-
-
0024206182
-
Spark-generating properties of electrode gels used during defibrillation A potential fire hazard
-
Hummel 3rd RS, Ornato JP, Weinberg SM, Clarke AM. Spark-generating properties of electrode gels used during defibrillation. A potential fire hazard. JAMA 1988;260:3021-4.
-
(1988)
JAMA
, vol.260
, pp. 3021-3024
-
-
Hummel 3rd, R.S.1
Ornato, J.P.2
Weinberg, S.M.3
Clarke, A.M.4
-
175
-
-
28444455654
-
Risk of fire when using defibrillation in an oxygen enriched atmosphere
-
Lefever J, Smith A. Risk of fire when using defibrillation in an oxygen enriched atmosphere. Med Devices Agency Saf Notices 1995;3:1-3.
-
(1995)
Med Devices Agency Saf Notices
, vol.3
, pp. 1-3
-
-
Lefever, J.1
Smith, A.2
-
176
-
-
0041336969
-
Fire attributable to a defibrillation attempt in a neonate
-
Theodorou AA, Gutierrez JA, Berg RA. Fire attributable to a defibrillation attempt in a neonate. Pediatrics 2003;112:677-9.
-
(2003)
Pediatrics
, vol.112
, pp. 677-679
-
-
Theodorou, A.A.1
Gutierrez, J.A.2
Berg, R.A.3
-
177
-
-
0031858718
-
Ambient oxygen concentrations during simulated cardiopulmonary resuscitation
-
Robertshaw H, McAnulty G. Ambient oxygen concentrations during simulated cardiopulmonary resuscitation. Anaesthesia 1998;53:634-7.
-
(1998)
Anaesthesia
, vol.53
, pp. 634-637
-
-
Robertshaw, H.1
McAnulty, G.2
-
178
-
-
0031847959
-
The question of removing a ventilation bag before defibrillation
-
Cantello E, Davy TE, Koenig KL. The question of removing a ventilation bag before defibrillation. J Accid Emerg Med 1998;15:286.
-
(1998)
J Accid Emerg Med
, vol.15
, pp. 286
-
-
Cantello, E.1
Davy, T.E.2
Koenig, K.L.3
-
179
-
-
34347373856
-
Ambient oxygen concentrations resulting from use of the Lund University Cardiopulmonary Assist System (LUCAS) device during simulated cardiopulmonary resuscitation
-
Deakin CD, Paul V, Fall E, Petley GW, Thompson F. Ambient oxygen concentrations resulting from use of the Lund University Cardiopulmonary Assist System (LUCAS) device during simulated cardiopulmonary resuscitation. Resuscitation 2007;74:303-9.
-
(2007)
Resuscitation
, vol.74
, pp. 303-309
-
-
Deakin, C.D.1
Paul, V.2
Fall, E.3
Petley, G.W.4
Thompson, F.5
|