메뉴 건너뛰기




Volumn , Issue , 2008, Pages 16-21

Bi2O3/Nb2O5 thick film capacitive pH sensor using AD5933 impedance converter

Author keywords

Impedance converter; Mixed metal oxides; pH sensor; Real time; Thick film

Indexed keywords

BISMUTH COMPOUNDS; CAPACITIVE SENSORS; NATURAL FREQUENCIES; NIOBIUM OXIDE; PH; THICK FILMS;

EID: 78649727730     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/sas13374.2008.4472935     Document Type: Conference Paper
Times cited : (3)

References (16)
  • 1
    • 33746860403 scopus 로고    scopus 로고
    • Dynamics of Muscle Glycogenolysis Modeled with pH Time Course Computation and pH-Dependent Reaction Equilibria and Enzyme Kinetics
    • Aug.
    • K. Vinnakota, M. L. Kemp, and M. J. Kushmerick, "Dynamics of Muscle Glycogenolysis Modeled with pH Time Course Computation and pH-Dependent Reaction Equilibria and Enzyme Kinetics", Biophys. J., vol. 91, pp. 1264-1287, Aug. 2006.
    • (2006) Biophys. J. , vol.91 , pp. 1264-1287
    • Vinnakota, K.1    Kemp, M.L.2    Kushmerick, M.J.3
  • 2
    • 33645704045 scopus 로고    scopus 로고
    • Redox-sensitive copolymer: A single-component pH sensor
    • Apr.
    • K. L. Robinson and N. S. Lawrence, "Redox-sensitive copolymer: A single-component pH sensor", Analytical Chemistry, vol. 78, pp. 2450-2455, Apr. 2006.
    • (2006) Analytical Chemistry , vol.78 , pp. 2450-2455
    • Robinson, K.L.1    Lawrence, N.S.2
  • 3
    • 34848904287 scopus 로고    scopus 로고
    • Investigation of tin oxides as sensing layers in conductimetric interdigitated pH sensors
    • Oct.
    • K. Arshak, E. Gill, A. Arshak, and O. Korostynska, "Investigation of tin oxides as sensing layers in conductimetric interdigitated pH sensors", Sensors and Actuators B: Chemical, vol. 127, pp. 42-53, Oct. 2007.
    • (2007) Sensors and Actuators B: Chemical , vol.127 , pp. 42-53
    • Arshak, K.1    Gill, E.2    Arshak, A.3    Korostynska, O.4
  • 4
    • 70349718271 scopus 로고    scopus 로고
    • Review Paper: Materials and Techniques for in Vivo pH Monitoring
    • Jan.
    • O. Korostynska, K. Arshak, E. Gill, and A. Arshak, "Review Paper: Materials and Techniques for In Vivo pH Monitoring", Sensors Journal, IEEE, vol. 8, pp. 17-25, Jan. 2008.
    • (2008) Sensors Journal, IEEE , vol.8 , pp. 17-25
    • Korostynska, O.1    Arshak, K.2    Gill, E.3    Arshak, A.4
  • 5
    • 39749168341 scopus 로고    scopus 로고
    • Review on State-of-the-art in Polymer Based pH Sensors
    • Nov.
    • O. Korostynska, K. Arshak, E. Gill, and A. Arshak, "Review on State-of-the-art in Polymer Based pH Sensors", Sensors, vol. 7, pp. 3027-3042, Nov. 2007.
    • (2007) Sensors , vol.7 , pp. 3027-3042
    • Korostynska, O.1    Arshak, K.2    Gill, E.3    Arshak, A.4
  • 6
    • 39749091675 scopus 로고    scopus 로고
    • pH Sensitivity of Novel PANI/PVB/PS3 Composite Films
    • Dec.
    • E. Gill, A. Arshak, K. Arshak, and O. Korostynska, "pH Sensitivity of Novel PANI/PVB/PS3 Composite Films", Sensors, vol. 7, pp. 3329-3346, Dec. 2007.
    • (2007) Sensors , vol.7 , pp. 3329-3346
    • Gill, E.1    Arshak, A.2    Arshak, K.3    Korostynska, O.4
  • 9
    • 0035157273 scopus 로고    scopus 로고
    • In vitro and in vivo measurements of fiber optic and electrochemical sensors to monitor brain tissue pH
    • Jan.
    • S. A. Grant, K. Bettencourt, P. Krulevitch, J. Hamilton, and R. Glass, "In vitro and in vivo measurements of fiber optic and electrochemical sensors to monitor brain tissue pH", Sensors and Actuators B: Chemical, vol. 72, pp. 174-179, Jan. 2001.
    • (2001) Sensors and Actuators B: Chemical , vol.72 , pp. 174-179
    • Grant, S.A.1    Bettencourt, K.2    Krulevitch, P.3    Hamilton, J.4    Glass, R.5
  • 12
    • 0027068213 scopus 로고
    • Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in vivo applications
    • G. Urban, G. Jobst, F. Keplinger, E. Aschauer, O. Tilado, R. Fasching et al., "Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in vivo applications", Biosensors & Bioelectronics, vol. 7, pp. 733-739, 1992.
    • (1992) Biosensors & Bioelectronics , vol.7 , pp. 733-739
    • Urban, G.1    Jobst, G.2    Keplinger, F.3    Aschauer, E.4    Tilado, O.5    Fasching, R.6
  • 13
    • 0037429122 scopus 로고    scopus 로고
    • pH sensor based on deposited film of lead oxide on aluminum substrate electrode
    • Feb.
    • A. Eftekhari, "pH sensor based on deposited film of lead oxide on aluminum substrate electrode", Sensors and Actuators B: Chemical, vol. 88, pp. 234-238, Feb. 2003.
    • (2003) Sensors and Actuators B: Chemical , vol.88 , pp. 234-238
    • Eftekhari, A.1
  • 14
    • 0004626924 scopus 로고    scopus 로고
    • pH-Response of nanosized MnO2 prepared with solid state reaction route at room temperature
    • Oct.
    • L. Qingwen, W. Yiming, and L. Guoan, "pH-Response of nanosized MnO2 prepared with solid state reaction route at room temperature", Sensors and Actuators B: Chemical, vol. 59, pp. 42-47, Oct. 1999.
    • (1999) Sensors and Actuators B: Chemical , vol.59 , pp. 42-47
    • Qingwen, L.1    Yiming, W.2    Guoan, L.3
  • 15
    • 0033997415 scopus 로고    scopus 로고
    • Response of nanosized cobalt oxide electrodes as pH sensors
    • Mar.
    • L. Qingwen, L. Guoan, and S. Youqin, "Response of nanosized cobalt oxide electrodes as pH sensors", Analytica Chimica Acta, vol. 409, pp. 137-142, Mar. 2000.
    • (2000) Analytica Chimica Acta , vol.409 , pp. 137-142
    • Qingwen, L.1    Guoan, L.2    Youqin, S.3
  • 16
    • 0030827437 scopus 로고    scopus 로고
    • Screen-printed ruthenium dioxide electrodes for pH measurements
    • Sept.
    • R. Koncki and M. Mascini, "Screen-printed ruthenium dioxide electrodes for pH measurements", Analytica Chimica Acta, vol. 351, pp. 143-149, Sept. 1997.
    • (1997) Analytica Chimica Acta , vol.351 , pp. 143-149
    • Koncki, R.1    Mascini, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.