메뉴 건너뛰기




Volumn 31, Issue 10, 2010, Pages

Possible mechanisms for delayed migration of the closed cell-designed enterprise stent when used in the adjunctive treatment of a basilar artery aneurysm

Author keywords

[No Author keywords available]

Indexed keywords

ARTERY DIAMETER; BASILAR ARTERY; BLOOD VESSEL WALL; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; IN-STENT RESTENOSIS; INTRACRANIAL ANEURYSM; LETTER; POSTERIOR CEREBRAL ARTERY; PROSTHESIS; PROSTHESIS FAILURE; STENT; STENT THROMBOSIS;

EID: 78649673030     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A2258     Document Type: Letter
Times cited : (34)

References (5)
  • 1
    • 56849093972 scopus 로고    scopus 로고
    • Delayed migration of a self-expanding intracranial microstent
    • Kelly ME, Turner RD, Moskowitz SI, et al. Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 2008;29:1959-60
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1959-1960
    • Kelly, M.E.1    Turner, R.D.2    Moskowitz, S.I.3
  • 3
    • 67650742249 scopus 로고    scopus 로고
    • Spontaneous delayed proximal migration of Enterprise stent after staged treatment of wide-necked basilar aneurysm: Technical case report
    • discussion E1012
    • Lavine SD, Meyers PM, Connolly ES, et al. Spontaneous delayed proximal migration of Enterprise stent after staged treatment of wide-necked basilar aneurysm: technical case report. Neurosurgery 2009;64:E1012, discussion E1012
    • (2009) Neurosurgery , vol.64
    • Lavine, S.D.1    Meyers, P.M.2    Connolly, E.S.3
  • 4
    • 33646192862 scopus 로고    scopus 로고
    • Increased cell opening and prolapse of struts of a Neuroform stent in curved vasculature: Value of angiographic computed tomography - Technical case report
    • discussion ONS-E380
    • Benndorf G, Claus B, Strother CM, et al. Increased cell opening and prolapse of struts of a Neuroform stent in curved vasculature: value of angiographic computed tomography - technical case report. Neurosurgery 2006;58:ONS-E380, discussion ONS-E380
    • (2006) Neurosurgery , vol.58
    • Benndorf, G.1    Claus, B.2    Strother, C.M.3
  • 5
    • 34248639072 scopus 로고    scopus 로고
    • Stent conformity in curved vascular models with simulated aneurysm weeks using Flat-Panel CT: An in vitro study
    • Ebrahimi N, Claus B, Lee CY, et al. Stent conformity in curved vascular models with simulated aneurysm necks using flat panel CT: an in vitro study. AJNR Am J Neuroradiol 2007;28:823-29 (Pubitemid 46776055)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.5 , pp. 823-829
    • Ebrahimi, N.1    Claus, B.2    Lee, C.-Y.3    Biondi, A.4    Benndorf, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.