Volumn 12, Issue 10, 2010, Pages 717-723

Intra-operative ultrasound elasticity imaging for monitoring of hepatic tumour thermal ablation

Author keywords

adiological intervention treatment; colorectal metastases; hepatocellular carcinoma; liver cancer; palliation; radio frequency

Indexed keywords

ACCURACY; ARTICLE; B SCAN; CLINICAL ARTICLE; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; CONTROLLED STUDY; CORRELATION ANALYSIS; FEASIBILITY STUDY; HUMAN; LIVER CELL CARCINOMA; LIVER METASTASIS; NONHUMAN; PATIENT MONITORING; PEROPERATIVE ECHOGRAPHY; PILOT STUDY; RADIOFREQUENCY ABLATION; SWINE; TUMOR ABLATION; ULTRASOUND ELASTICITY IMAGING;

EID: 78649657591     PISSN: 1365182X     EISSN: 14772574     Source Type: Journal    
DOI: 10.1111/j.1477-2574.2010.00247.x     Document Type: Article
Times cited : (47)

References (21)
  • 1
    • 33644662778 scopus 로고    scopus 로고
    • A prospective randomized trial comparing percutaneous local ablative therapy and partial hepatectomy for small hepatocellular carcinoma
    • Chen MS, Li JQ, Zheng Y, Guo RP, Liang HH, Zhang YQ, et al. (2006) A prospective randomized trial comparing percutaneous local ablative therapy and partial hepatectomy for small hepatocellular carcinoma. Ann Surg 243: 321-328.
    • (2006) Ann Surg , vol.243 , pp. 321-328
    • Chen, M.S.1    Li, J.Q.2    Zheng, Y.3    Guo, R.P.4    Liang, H.H.5    Zhang, Y.Q.6
  • 2
    • 22744441092 scopus 로고    scopus 로고
    • Local recurrence after hepatic radiofrequency coagulation: Multivariate meta-analysis and review of contributing factors
    • Mulier S, Ni Y, Jamart J, Ruers T, Marchal G, Michel L,. (2005) Local recurrence after hepatic radiofrequency coagulation: multivariate meta-analysis and review of contributing factors. Ann Surg 242: 158-171.
    • (2005) Ann Surg , vol.242 , pp. 158-171
    • Mulier, S.1    Ni, Y.2    Jamart, J.3    Ruers, T.4    Marchal, G.5    Michel, L.6
  • 4
    • 0036103427 scopus 로고    scopus 로고
    • Sonographically observed echogenic response during intraoperative radiofrequency ablation of cirrhotic livers: Pathologic correlation
    • Leyendecker JR, Dodd GD, 3rd, Halff GA, McCoy VA, Napier DH, Hubbard LG, et al. (2002) Sonographically observed echogenic response during intraoperative radiofrequency ablation of cirrhotic livers: pathologic correlation. AJR Am J Roentgenol 178: 1147-1151.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1147-1151
    • Leyendecker, J.R.1    Dodd III, G.D.2    Halff, G.A.3    McCoy, V.A.4    Napier, D.H.5    Hubbard, L.G.6
  • 5
    • 33750127191 scopus 로고    scopus 로고
    • Imaging features of hepatocellular carcinoma after transcatheter arterial chemoembolization and radiofrequency ablation
    • Lim HS, Jeong YY, Kang HK, Kim JK, Park JG,. (2006) Imaging features of hepatocellular carcinoma after transcatheter arterial chemoembolization and radiofrequency ablation. AJR Am J Roentgenol 187: W341-W349.
    • (2006) AJR Am J Roentgenol , vol.187
    • Lim, H.S.1    Jeong, Y.Y.2    Kang, H.K.3    Kim, J.K.4    Park, J.G.5
  • 6
    • 61849180246 scopus 로고    scopus 로고
    • Spectrum of CT findings after radiofrequency ablation of hepatic tumors
    • discussion 390-392.
    • Park MH, Rhim H, Kim YS, Choi D, Lim HK, Lee WJ,. (2008) Spectrum of CT findings after radiofrequency ablation of hepatic tumors. Radiographics 28: 379-390, discussion 390-392.
    • (2008) Radiographics , vol.28 , pp. 379-390
    • Park, M.H.1    Rhim, H.2    Kim, Y.S.3    Choi, D.4    Lim, H.K.5    Lee, W.J.6
  • 7
    • 0025806883 scopus 로고
    • Elastography: A quantitative method for imaging the elasticity of biological tissues
    • Ophir J, Cespedes I, Ponnekanti H, Yazdi Y, Li X,. (1991) Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging 13: 111-134.
    • (1991) Ultrason Imaging , vol.13 , pp. 111-134
    • Ophir, J.1    Cespedes, I.2    Ponnekanti, H.3    Yazdi, Y.4    Li, X.5
  • 8
    • 67349245141 scopus 로고    scopus 로고
    • Investigation of temperature-dependent viscoelastic properties of thermal lesions in ex vivo animal liver tissue
    • Kiss MZ, Daniels MJ, Varghese T,. (2009) Investigation of temperature-dependent viscoelastic properties of thermal lesions in ex vivo animal liver tissue. J Biomech 42: 959-966.
    • (2009) J Biomech , vol.42 , pp. 959-966
    • Kiss, M.Z.1    Daniels, M.J.2    Varghese, T.3
  • 9
    • 50949133880 scopus 로고    scopus 로고
    • A novel technique for creating solid renal pseudotumors and renal vein-inferior vena caval pseudothrombus in a porcine and cadaveric model
    • Eun D, Bhandari A, Boris R, Lyall K, Bhandari M, Menon M, et al. (2008) A novel technique for creating solid renal pseudotumors and renal vein-inferior vena caval pseudothrombus in a porcine and cadaveric model. J Urol 180: 1510-1514.
    • (2008) J Urol , vol.180 , pp. 1510-1514
    • Eun, D.1    Bhandari, A.2    Boris, R.3    Lyall, K.4    Bhandari, M.5    Menon, M.6
  • 13
    • 56649086604 scopus 로고    scopus 로고
    • Diagnostic performance of contrast-enhanced computed tomography in the immediate assessment of radiofrequency ablation success in colorectal liver metastases
    • Schraml C, Clasen S, Schwenzer NF, Koenigsrainer I, Herberts T, Claussen CD, et al. (2008) Diagnostic performance of contrast-enhanced computed tomography in the immediate assessment of radiofrequency ablation success in colorectal liver metastases. Abdom Imaging 33: 643-651.
    • (2008) Abdom Imaging , vol.33 , pp. 643-651
    • Schraml, C.1    Clasen, S.2    Schwenzer, N.F.3    Koenigsrainer, I.4    Herberts, T.5    Claussen, C.D.6
  • 14
    • 0033766550 scopus 로고    scopus 로고
    • Creation of radiofrequency lesions in a porcine model: Correlation with sonography, CT, and histopathology
    • Raman SS, Lu DS, Vodopich DJ, Sayre J, Lassman C,. (2000) Creation of radiofrequency lesions in a porcine model: correlation with sonography, CT, and histopathology. AJR Am J Roentgenol 175: 1253-1258.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 1253-1258
    • Raman, S.S.1    Lu, D.S.2    Vodopich, D.J.3    Sayre, J.4    Lassman, C.5
  • 15
    • 44349145469 scopus 로고    scopus 로고
    • Radio-frequency ablation electrode displacement elastography: A phantom study
    • Bharat S, Varghese T, Madsen EL, Zagzebski JA,. (2008) Radio-frequency ablation electrode displacement elastography: a phantom study. Med Phys 35: 2432-2442.
    • (2008) Med Phys , vol.35 , pp. 2432-2442
    • Bharat, S.1    Varghese, T.2    Madsen, E.L.3    Zagzebski, J.A.4
  • 16
    • 46249132393 scopus 로고    scopus 로고
    • Ultrasound-based elastography: A novel approach to assess radio frequency ablation of liver masses performed with expandable ablation probes: A feasibility study
    • Kolokythas O, Gauthier T, Fernandez AT, Xie H, Timm BA, Cuevas C, et al. (2008) Ultrasound-based elastography: a novel approach to assess radio frequency ablation of liver masses performed with expandable ablation probes: a feasibility study. J Ultrasound Med 27: 935-946.
    • (2008) J Ultrasound Med , vol.27 , pp. 935-946
    • Kolokythas, O.1    Gauthier, T.2    Fernandez, A.T.3    Xie, H.4    Timm, B.A.5    Cuevas, C.6
  • 17
    • 50449095258 scopus 로고    scopus 로고
    • Real-time sonoelastography of hepatic thermal lesions in a swine model
    • Zhang M, Castaneda B, Christensen J, Saad WE, Bylund K, Hoyt K, et al. (2008) Real-time sonoelastography of hepatic thermal lesions in a swine model. Med Phys 35: 4132-4141.
    • (2008) Med Phys , vol.35 , pp. 4132-4141
    • Zhang, M.1    Castaneda, B.2    Christensen, J.3    Saad, W.E.4    Bylund, K.5    Hoyt, K.6
  • 18
    • 52049098922 scopus 로고    scopus 로고
    • In vivo guidance and assessment of liver radio-frequency ablation with acoustic radiation force elastography
    • Fahey BJ, Nelson RC, Hsu SJ, Bradway DP, Dumont DM, Trahey GE,. (2008) In vivo guidance and assessment of liver radio-frequency ablation with acoustic radiation force elastography. Ultrasound Med Biol 34: 1590-1603.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 1590-1603
    • Fahey, B.J.1    Nelson, R.C.2    Hsu, S.J.3    Bradway, D.P.4    Dumont, D.M.5    Trahey, G.E.6
  • 19
    • 77958086288 scopus 로고    scopus 로고
    • Intra-operative freehand real-time elastography for small focal liver lesions: 'Visual palpation' for non-palpable tumors
    • Inoue Y, Takahashi M, Arita J, Aoki T, Hasegawa K, Beck Y, et al. (2010) Intra-operative freehand real-time elastography for small focal liver lesions: 'visual palpation' for non-palpable tumors. Surgery 148: 1000-1011.
    • (2010) Surgery , vol.148 , pp. 1000-1011
    • Inoue, Y.1    Takahashi, M.2    Arita, J.3    Aoki, T.4    Hasegawa, K.5    Beck, Y.6
  • 20
    • 33646150005 scopus 로고    scopus 로고
    • Breast disease: Clinical application of US elastography for diagnosis
    • Itoh A, Ueno E, Tohno E, Kamma H, Takahashi H, Shiina T, et al. (2006) Breast disease: clinical application of US elastography for diagnosis. Radiology 239: 341-350.
    • (2006) Radiology , vol.239 , pp. 341-350
    • Itoh, A.1    Ueno, E.2    Tohno, E.3    Kamma, H.4    Takahashi, H.5    Shiina, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.