메뉴 건너뛰기




Volumn 4, Issue 6 PART 1, 2010, Pages 340-349

A miniature-implantable RF-wireless active glaucoma intraocular pressure monitor

Author keywords

Biomedical applications of electromagnetic radiation; biomedical monitoring; biomedical telemetry; implantable biomedical devices

Indexed keywords

BIOMEDICAL APPLICATIONS OF ELECTROMAGNETIC RADIATION; BIOMEDICAL MONITORING; BIOMEDICAL TELEMETRY; CLOSED-LOOP; CONTINUOUS MONITORING; IMPLANTABLE BIOMEDICAL DEVICES; INTRA OCULAR PRESSURE; MICROELECTROMECHANICAL SYSTEMS; MONITORING DEVICE; MONOPOLE ANTENNA; POWER STORAGE; SIDE EFFECT; TEXAS INSTRUMENTS; TREATMENT SYSTEMS; WIRELESS OPERATION; WORK FOCUS;

EID: 78649636879     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2010.2081364     Document Type: Conference Paper
Times cited : (135)

References (38)
  • 1
    • 33644655886 scopus 로고    scopus 로고
    • The number of people with glaucoma worldwide in 2010 and 2020
    • H. A. Quigley and A. T. Broman, "The number of people with glaucoma worldwide in 2010 and 2020", Brit. J Ophthalmol., vol. 90, pp. 262-267, 2006.
    • (2006) Brit. J. Ophthalmol. , vol.90 , pp. 262-267
    • Quigley, H.A.1    Broman, A.T.2
  • 2
    • 0014242615 scopus 로고
    • Diurnal variation of intraocular pressure in healthy, suspected and glaucomatous eyes
    • R. C. N. Sampaolesi, C. A. de Carvalho, and R. Reca, "Diurnal variation of intraocular pressure in healthy, suspected and glaucomatous eyes", Bibl Ophthalmol., vol. 74, pp. 1-23, 1968.
    • (1968) Bibl Ophthalmol. , vol.74 , pp. 1-23
    • Sampaolesi, R.C.N.1    De Carvalho, C.A.2    Reca, R.3
  • 3
    • 0026349823 scopus 로고
    • Diurnal variations in intraocular pressure
    • J. T. Wilensky, "Diurnal variations in intraocular pressure", Trans. Amer. Ophthalmol. Soc., vol. 89, pp. 757-790, 1991.
    • (1991) Trans. Amer. Ophthalmol. Soc. , vol.89 , pp. 757-790
    • Wilensky, J.T.1
  • 7
    • 78649630950 scopus 로고    scopus 로고
    • Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes
    • M. Leonardi, E. M. Pitchon, A. Bertsch, P. Renaud, and A. Mermoud, "Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes", Acta Ophthalmol., 2008.
    • (2008) Acta Ophthalmol.
    • Leonardi, M.1    Pitchon, E.M.2    Bertsch, A.3    Renaud, P.4    Mermoud, A.5
  • 8
    • 57449102575 scopus 로고    scopus 로고
    • Microfabricated implantable parylene-based wireless passive intraocular pressure sensors
    • C. Po-Jui, D. C. Rodger, S. Saati, M. S. Humayun, and T. Yu-Chong, "Microfabricated implantable parylene-based wireless passive intraocular pressure sensors", J. Microelectromechan. Syst., vol. 17, pp. 1342-1351, 2008.
    • (2008) J. Microelectromechan. Syst. , vol.17 , pp. 1342-1351
    • Po-Jui, C.1    Rodger, D.C.2    Saati, S.3    Humayun, M.S.4    Yu-Chong, T.5
  • 10
    • 0000298124 scopus 로고    scopus 로고
    • Hermetically sealed inductor-capacitor (LC) resonator for remote pressure monitoring
    • J.-B. Y. a. E. Y. E.-C. Park, "Hermetically sealed inductor-capacitor (LC) resonator for remote pressure monitoring", Jpn. J. Appl. Phys., vol. 37, pp. 7124-7128, 1998.
    • (1998) Jpn. J. Appl. Phys. , vol.37 , pp. 7124-7128
    • Park, J.-B.Y.A.E.Y.1
  • 14
    • 0025698114 scopus 로고
    • Passive silicone transensor intended for biomedical, remote pressure monitoring
    • L. R. Y. Backlund, B. Hok, and B. Svedbergh, "Passive silicone transensor intended for biomedical, remote pressure monitoring", Sens. Actuators, A, pp. 58-61, 1990.
    • (1990) Sens. Actuators, A , pp. 58-61
    • Backlund, L.R.Y.1    Hok, B.2    Svedbergh, B.3
  • 15
    • 0026913146 scopus 로고
    • A system for wireless intra-ocular pressure measurements using a silicon micromachined sensor
    • Y. B. L. Rosengren, T. Sjostrom, B. Hok, and B. Svedbergh, "A system for wireless intra-ocular pressure measurements using a silicon micromachined sensor", J. Micromech. Microeng., vol. 2, pp. 202-204, 1992.
    • (1992) J. Micromech. Microeng. , vol.2 , pp. 202-204
    • Rosengren, Y.B.L.1    Sjostrom, T.2    Hok, B.3    Svedbergh, B.4
  • 18
    • 77952129638 scopus 로고    scopus 로고
    • Mixed-signal integrated circuits for self-contained sub-cubic millimeter biomedical implants
    • presented at, San Francisco, CA
    • E. Y. Chow, S. Chakraborty, W. J. Chappell, and P. P. Irazoqui, "Mixed-signal integrated circuits for self-contained sub-cubic millimeter biomedical implants", presented at the Int. Solid State Circuits Conf., San Francisco, CA, 2010.
    • (2010) The Int. Solid State Circuits Conf.
    • Chow, E.Y.1    Chakraborty, S.2    Chappell, W.J.3    Irazoqui, P.P.4
  • 19
    • 0032123754 scopus 로고    scopus 로고
    • Embedded 5 V-to-3.3 V voltage regulator for supplying digital IC's in 3.3 V CMOS technology
    • Jul
    • G. W. den Besten and B. Nauta, "Embedded 5 V-to-3.3 V voltage regulator for supplying digital IC's in 3.3 V CMOS technology", IEEE J. Solid-State Circuits, vol. 33, no. 7, pp. 956-962, Jul. 1998.
    • (1998) IEEE J. Solid-state Circuits , vol.33 , Issue.7 , pp. 956-962
    • Der Besten, G.W.1    Nauta, B.2
  • 20
    • 0022733092 scopus 로고
    • A new on-chip converter for submicrometer high-density DRAMs
    • Jun
    • T. Furuyama, Y. Watanabe, T. Ohsawa, and S. Watanabe, "A new on-chip converter for submicrometer high-density DRAMs", IEEE J. Solid-State Circuits, vol. SSC-22, no. 3, pp. 437-441, Jun. 1987.
    • (1987) IEEE J. Solid-state Circuits , vol.SSC-22 , Issue.3 , pp. 437-441
    • Furuyama, T.1    Watanabe, Y.2    Ohsawa, T.3    Watanabe, S.4
  • 21
    • 33644500593 scopus 로고    scopus 로고
    • A wide-range supply-independent CMOS voltage reference for telemetry-powering applications
    • A. M. Sodagar and K. Najafi, "A wide-range supply-independent CMOS voltage reference for telemetry-powering applications", in Proc. 9th Int. Conf. Electronics, Circuits and Systems, 2002, vol. 1, pp. 401-404.
    • (2002) Proc. 9th Int. Conf. Electronics, Circuits and Systems , vol.1 , pp. 401-404
    • Sodagar, A.M.1    Najafi, K.2
  • 26
    • 0003303686 scopus 로고    scopus 로고
    • Liquid crystal polymers and their role in electronic packaging
    • K. Jayaraj and B. Farrell, "Liquid crystal polymers and their role in electronic packaging", Adv Microelectron., vol. 25, pp. 15-18, 1998.
    • (1998) Adv. Microelectron. , vol.25 , pp. 15-18
    • Jayaraj, K.1    Farrell, B.2
  • 27
    • 0141495467 scopus 로고    scopus 로고
    • Liquid crystal polymer (LCP) for MEMS: Process and applications
    • X. Wang, J. Engel, and C. Liu, "Liquid crystal polymer (LCP) for MEMS: Process and applications", J. Micromech. Microeng., vol. 13, pp. 628-633, 2003.
    • (2003) J. Micromech. Microeng. , vol.13 , pp. 628-633
    • Wang, X.1    Engel, J.2    Liu, C.3
  • 28
    • 0029269045 scopus 로고
    • Biocompatibility of cochlear implants
    • C. Chouard and P. Pialoux, "Biocompatibility of cochlear implants", Bull. Acad. Natl. Med, vol. 179, pp. 549-555, 1995.
    • (1995) Bull. Acad. Natl. Med. , vol.179 , pp. 549-555
    • Chouard, C.1    Pialoux, P.2
  • 29
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • D. R. Merrill, M. Bikson, and J. Jefferys, "Electrical stimulation of excitable tissue: Design of efficacious and safe protocols", J. Neurosci. Meth., vol. 141, pp. 171-198, 2005.
    • (2005) J. Neurosci. Meth. , vol.141 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.3
  • 30
    • 73349124802 scopus 로고    scopus 로고
    • Development of microelectrode arrays for artificial retinal implants using liquid crystal polymers
    • S. W. Lee, J.-M. Seo, S. Ha, E. T. Kim, H. Chung, and S. J. Kim, "Development of microelectrode arrays for artificial retinal implants using liquid crystal polymers", Invest. Ophthalmol. Vis. Sci., vol. 50, 2009.
    • (2009) Invest. Ophthalmol. Vis. Sci. , vol.50
    • Lee, S.W.1    Seo, J.-M.2    Ha, S.3    Kim, E.T.4    Chung, H.5    Kim, S.J.6
  • 35
    • 0037222681 scopus 로고    scopus 로고
    • Artificial vitreous replacements
    • N. Soman and R. Banerjee, "Artificial vitreous replacements", Bio-Med. Mater. Eng., vol. 13, pp. 59-74, 2003.
    • (2003) Bio-Med. Mater. Eng. , vol.13 , pp. 59-74
    • Soman, N.1    Banerjee, R.2
  • 37
    • 28444475214 scopus 로고    scopus 로고
    • The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
    • A. Kotecha, E. T. White, J. M. Shewry, and D. F. Garway-Heath, "The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry", Brit. J. Ophthalmol, vol. 89, pp. 1572-1575, 2005.
    • (2005) Brit. J. Ophthalmol. , vol.89 , pp. 1572-1575
    • Kotecha, A.1    White, E.T.2    Shewry, J.M.3    Garway-Heath, D.F.4
  • 38
    • 0035720693 scopus 로고    scopus 로고
    • Micro-transponder systems for medical applications
    • Sep
    • W. Mokwa and U. Schnakenberg, "Micro-transponder systems for medical applications", IEEE Trans. Instrum. Meas., vol. 50, no. 6, pp. 1551-1555, Sep. 2001.
    • (2001) IEEE Trans. Instrum. Meas. , vol.50 , Issue.6 , pp. 1551-1555
    • Mokwa, W.1    Schnakenberg, U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.