메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Enhancement of low voltage ride-through capability for wind turbine driven DFIG with active crowbar and battery energy storage system

Author keywords

Battery energy storage system; Crowbar; DC voltage ripple; Doubly fed induction generator; Fault ride through; Hysteresis control; Low voltage ride through; Protection

Indexed keywords

BATTERY ENERGY STORAGE SYSTEMS; CROWBAR; DC VOLTAGE; DOUBLY FED INDUCTION GENERATOR; FAULT RIDE-THROUGH; HYSTERESIS CONTROL; LOW-VOLTAGE RIDE-THROUGH; PROTECTION;

EID: 78649596669     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2010.5588180     Document Type: Conference Paper
Times cited : (36)

References (14)
  • 2
    • 20544451598 scopus 로고    scopus 로고
    • Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip
    • J. Morren and S. W. H. de Haan, "Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip," IEEE Transactions on Energy Conversion, vol. 20, pp. 435-441, 2005.
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , pp. 435-441
    • Morren, J.1    De Haan, S.W.H.2
  • 4
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • X. Dawei, R. Li, P. J. Tavner, and S. Yang, "Control of a doubly fed induction generator in a wind turbine during grid fault ride-through," IEEE Transactions on Energy Conversion, vol. 21, pp. 652-662, 2006.
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , pp. 652-662
    • Dawei, X.1    Li, R.2    Tavner, P.J.3    Yang, S.4
  • 9
    • 65549131572 scopus 로고    scopus 로고
    • Research on control of DFIG with active crowbar under symmetry voltage fault condition
    • X. G. Zhang and D. G. Xu, "Research on control of DFIG with active crowbar under symmetry voltage fault condition," Dianji yu Kongzhi Xuebao/Electric Machines and Control, vol. 13, pp. 99-103, 2009.
    • (2009) Dianji Yu Kongzhi Xuebao/Electric Machines and Control , vol.13 , pp. 99-103
    • Zhang, X.G.1    Xu, D.G.2
  • 10
    • 35048853522 scopus 로고    scopus 로고
    • Performance Study of a Doubly Fed Wind-Power Induction Generator under Network Disturbances
    • S. Seman, J. Niiranen, S. Kanerva, A. Arkkio, and J. Saitz, "Performance Study of a Doubly Fed Wind-Power Induction Generator Under Network Disturbances," IEEE Transactions on Energy conversion, vol. 21, pp. 883-890, 2006.
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , pp. 883-890
    • Seman, S.1    Niiranen, J.2    Kanerva, S.3    Arkkio, A.4    Saitz, J.5
  • 12
    • 67650066427 scopus 로고    scopus 로고
    • Optimal design and economic evaluation of a battery energy storage system for the maximization of the energy generated by wind farms in isolated electric grids
    • E. Koutroulis, D. Kolokotsa, and G. Stravrakakis, "Optimal design and economic evaluation of a battery energy storage system for the maximization of the energy generated by wind farms in isolated electric grids," Wind Engineering, vol. 33, pp. 55-81, 2009.
    • (2009) Wind Engineering , vol.33 , pp. 55-81
    • Koutroulis, E.1    Kolokotsa, D.2    Stravrakakis, G.3
  • 14
    • 0036477636 scopus 로고    scopus 로고
    • Direct Torque Control of a Doubly-Fed Induction Generator for variable speed wind turbines
    • S. Arnalte and J. C. Burgos, "Direct Torque Control of a Doubly-Fed Induction Generator for variable speed wind turbines," Electric Power Components and Systems, vol. 30, pp. 199-216, 2002.
    • (2002) Electric Power Components and Systems , vol.30 , pp. 199-216
    • Arnalte, S.1    Burgos, J.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.