메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Wide-area coordinating control of SVCs and synchronous generators with signal transmission delay compensation

Author keywords

Coordination; Inter area oscillation; Remote signals; Smith predictor; Time delays; Wide area control

Indexed keywords

COORDINATION; INTER-AREA OSCILLATIONS; REMOTE SIGNALS; SMITH PREDICTORS; WIDE-AREA CONTROL;

EID: 78649561559     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2010.5590172     Document Type: Conference Paper
Times cited : (14)

References (22)
  • 2
    • 0035248520 scopus 로고    scopus 로고
    • Wide-area measurement based stabilizing control of large power systems - A decentralized/hierarchical approach
    • I. Kamwa, R. Grondin, and Y. Hebert, "Wide-area measurement based stabilizing control of large power systems - A decentralized/hierarchical approach," IEEE Transactions on Power Systems, vol. 16, pp. 136-153, 2001.
    • (2001) IEEE Transactions on Power Systems , vol.16 , pp. 136-153
    • Kamwa, I.1    Grondin, R.2    Hebert, Y.3
  • 4
    • 34548305170 scopus 로고    scopus 로고
    • A novel SVC supplementary controller based on wide area signals
    • Oct.
    • Y. Chang, Z. Xu, G. Cheng, and J. Xie, "A novel SVC supplementary controller based on wide area signals," Electric Power Systems Research, v 77, n 12, Oct. 2007, p 1569-1574.
    • (2007) Electric Power Systems Research , vol.77 , Issue.12 , pp. 1569-1574
    • Chang, Y.1    Xu, Z.2    Cheng, G.3    Xie, J.4
  • 5
    • 47149117391 scopus 로고    scopus 로고
    • Wide-area signal-based optimal neurocontroller for a UPFC
    • Jul.
    • S. Ray and G. K. Venayagamoorthy, "Wide-area signal-based optimal neurocontroller for a UPFC," IEEE Transactions on Power Delivery, vol. 23, pp. 1597-1605, Jul. 2008.
    • (2008) IEEE Transactions on Power Delivery , vol.23 , pp. 1597-1605
    • Ray, S.1    Venayagamoorthy, G.K.2
  • 7
    • 1442313421 scopus 로고    scopus 로고
    • Robust damping of multiple swing modes employing global stabilizing signals with a TCSC
    • Feb.
    • B. Chaudhuri and B. C. Pal, "Robust damping of multiple swing modes employing global stabilizing signals with a TCSC," IEEE Transactions on Power System, vol. 19, pp. 499-506, Feb. 2004.
    • (2004) IEEE Transactions on Power System , vol.19 , pp. 499-506
    • Chaudhuri, B.1    Pal, B.C.2
  • 8
    • 18444365910 scopus 로고    scopus 로고
    • Global power system control using generator excitation, PSS, FACTS devices and capacitor switching
    • June/July
    • J. S. K. Leung, D. J. Hill, and Y. Ni, "Global power system control using generator excitation, PSS, FACTS devices and capacitor switching," International Journal of Electrical Power and Energy Systems, vol. 27, pp. 448-464, June/July 2005.
    • (2005) International Journal of Electrical Power and Energy Systems , vol.27 , pp. 448-464
    • Leung, J.S.K.1    Hill, D.J.2    Ni, Y.3
  • 10
    • 37249000485 scopus 로고    scopus 로고
    • Real-time implementation of a measurement-based adaptive wide-area control system considering communication delays
    • S. Ray and G. K. Venayagamoorthy, "Real-time implementation of a measurement-based adaptive wide-area control system considering communication delays," IET Generation, Transmission and Distribution, vol. 2, pp. 62-70, 2008.
    • (2008) IET Generation, Transmission and Distribution , vol.2 , pp. 62-70
    • Ray, S.1    Venayagamoorthy, G.K.2
  • 11
    • 9244231172 scopus 로고    scopus 로고
    • Evaluation of Time delay Effects to Wide Area Power System Stabilizer design
    • November
    • H. Wu, K. S. Tsakalis, and G. T. Neydt, "Evaluation of Time delay Effects to Wide Area Power System Stabilizer design", IEEE Transactions on Power Systems, vol. 19, pp 1935-1941, November 2004.
    • (2004) IEEE Transactions on Power Systems , vol.19 , pp. 1935-1941
    • Wu, H.1    Tsakalis, K.S.2    Neydt, G.T.3
  • 12
    • 9244232325 scopus 로고    scopus 로고
    • Wide-area measurement-based stabilizing control of power system considering signal transmission delay
    • B. Chaudhuri, R. Majumder, and B. C. Pal, "Wide-area measurement-based stabilizing control of power system considering signal transmission delay," IEEE Transactions on Power Systems, vol. 19, pp. 1971-1979, 2004.
    • (2004) IEEE Transactions on Power Systems , vol.19 , pp. 1971-1979
    • Chaudhuri, B.1    Majumder, R.2    Pal, B.C.3
  • 14
    • 70350465361 scopus 로고    scopus 로고
    • Wide-area time-delay robust damping control for power system
    • Qi J, Jiang Q, Wang G, et al.: Wide-area time-delay robust damping control for power system. European Transactions on Electrical Power, 19:899-910, 2009.
    • (2009) European Transactions on Electrical Power , vol.19 , pp. 899-910
    • Qi, J.1    Jiang, Q.2    Wang, G.3
  • 15
    • 27144441786 scopus 로고    scopus 로고
    • Wide-area TCSC controller design in consideration of feedback signals' time delays
    • Institute of Electrical and Electronics Engineers Inc., New York, NY 10016-5997, United States
    • Quanyuan J, Zhenyu Z, Yijia C: Wide-area TCSC controller design in consideration of feedback signals' time delays, in 2005 IEEE Power Engineering Society General Meeting, Jun 12-16 2005, San Francisco, CA, United States2005, Institute of Electrical and Electronics Engineers Inc., New York, NY 10016-5997, United States, 2005, pp. 1676-1680.
    • (2005) 2005 IEEE Power Engineering Society General Meeting, Jun 12-16 2005, San Francisco, CA, United States2005 , pp. 1676-1680
    • Quanyuan, J.1    Zhenyu, Z.2    Yijia, C.3
  • 17
    • 0015604399 scopus 로고
    • An extension of the Smith predictor method to multivariable linear systems containing time delays
    • G. Alevisakis and D. E. Seborg, "An extension of the Smith predictor method to multivariable linear systems containing time delays," International Journal of Control, vol. 17, pp. 541-51, 1973.
    • (1973) International Journal of Control , vol.17 , pp. 541-551
    • Alevisakis, G.1    Seborg, D.E.2
  • 20
    • 1542299588 scopus 로고    scopus 로고
    • Modeling and closed-loop validation of a new PSS concept, the Multi-Band PSS
    • Panel Session on New PSS Technologies, Toronto, Canada
    • R. Grondin, I. Kamwa, G. Trudel, J. Taborda. "Modeling and closed-loop validation of a new PSS concept, the Multi-Band PSS" IEEE Power Engineering Society Summer Meeting, 2003, Panel Session on New PSS Technologies, Toronto, Canada.
    • IEEE Power Engineering Society Summer Meeting, 2003
    • Grondin, R.1    Kamwa, I.2    Trudel, G.3    Taborda, J.4
  • 22
    • 33745292641 scopus 로고    scopus 로고
    • New static Var compensator (SVC) based damping control using remote generator speed signal
    • R. Peng, R. K. Varma, and J. Jiang, "New static Var compensator (SVC) based damping control using remote generator speed signal," International Journal of Energy Technology and Policy, vol. 4, pp. 255-73, 2006.
    • (2006) International Journal of Energy Technology and Policy , vol.4 , pp. 255-273
    • Peng, R.1    Varma, R.K.2    Jiang, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.