메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Eccentricity and broken rotor bars faults - Effects on the external axial field

Author keywords

Axial flux; Broken rotor bar; Diagnosis; Eccentricity; External magnetic field; Harmonics; Induction motor; Spectral analysis

Indexed keywords

AXIAL FLUX; BROKEN ROTOR BAR; ECCENTRICITY; EXTERNAL MAGNETIC FIELD; HARMONICS; SPECTRAL ANALYSIS;

EID: 78649549711     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICELMACH.2010.5608009     Document Type: Conference Paper
Times cited : (30)

References (11)
  • 2
    • 29444455648 scopus 로고    scopus 로고
    • Induction machine fault diagnosis using an external radial flux sensor
    • R. Romary, R. Corton, D. Thailly, J.F. Brudny "Induction machine fault diagnosis using an external radial flux sensor," EPJ. Applied physics , 2005, vol. 32, No 2, pp. 125-132
    • (2005) EPJ. Applied Physics , vol.32 , Issue.2 , pp. 125-132
    • Romary, R.1    Corton, R.2    Thailly, D.3    Brudny, J.F.4
  • 4
    • 0242274222 scopus 로고    scopus 로고
    • A frequency-domain detection of stator winding faults in induction machines using an external flux sensor
    • H. Henao, C. Demian, G.A. Capolino, "A frequency-domain detection of stator winding faults in induction machines using an external flux sensor", IEEE Trans. on Industry Applications, Vol. 39, No 5, 2003, pp. 1272-1279.
    • (2003) IEEE Trans. on Industry Applications , vol.39 , Issue.5 , pp. 1272-1279
    • Henao, H.1    Demian, C.2    Capolino, G.A.3
  • 6
    • 78649543903 scopus 로고    scopus 로고
    • Analyse de l'excentricité d'une machine asynchrone à partir du flux axial
    • A. Ceban, "Analyse de l'excentricité d'une machine asynchrone à partir du flux axial," JCGE'09 Compiegne, France, 2009.
    • JCGE'09 Compiegne, France, 2009
    • Ceban, A.1
  • 8
    • 0029321518 scopus 로고
    • Transient analysis of cage induction machines under stator, rotor bar and end ring faults
    • Jun.
    • H. A. Toliyat and T. A. Lipo, "Transient analysis of cage induction machines under stator, rotor bar and end ring faults," IEEE Trans. Energy Convers., vol. 10, no. 2, pp. 241-247, Jun. 1995.
    • (1995) IEEE Trans. Energy Convers. , vol.10 , Issue.2 , pp. 241-247
    • Toliyat, H.A.1    Lipo, T.A.2
  • 9
    • 0026839813 scopus 로고
    • Modeling of saturated ac machines including air gap flux harmonic components
    • Mar./Apr.
    • J. Moreira and T. Lipo, "Modeling of saturated ac machines including air gap flux harmonic components," in IEEE Trans. Industry Applications, vol. 28, no. 2, pp. 343-349, Mar./Apr. 1992
    • (1992) IEEE Trans. Industry Applications , vol.28 , Issue.2 , pp. 343-349
    • Moreira, J.1    Lipo, T.2