Volumn , Issue , 2010, Pages

The analysis of the infrared excitation winding surface temperature measurement on a synchronous hydro-generator in rotation

Author keywords

Infrared image sensors; Rotating machine measurements; Synchronous generator; Temperature measurement

Indexed keywords

EXCITATION WINDING; HYDRO GENERATOR; INFRARED EXCITATION; INFRARED IMAGE SENSORS; ROTATING MACHINE; SPACE SIZE; SURFACE TEMPERATURE MEASUREMENT; SURFACE TEMPERATURES; THERMAL RADIATIONS;

EID: 78649533881     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICELMACH.2010.5608080     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 3
    • 35748973247 scopus 로고    scopus 로고
    • Measurements on rotating blades using IR thermography
    • November
    • M. Moria, L. Novaka and M. Sekavcnik, Measurements on rotating blades using IR thermography, Experimental Thermal and Fluid Science Volume 32, Issue 2, November 2007, Pages 387-396
    • (2007) Experimental Thermal and Fluid Science , vol.32 , Issue.2 , pp. 387-396
    • Moria, M.1    Novaka, L.2    Sekavcnik, M.3
  • 4
    • 0005085478 scopus 로고    scopus 로고
    • High speed IR camera for contactless temperature measurement on rotating tires
    • H. Budzier, M. Zimmerhackl, V. Krause, and G. Hoven, High speed IR camera for contactless temperature measurement on rotating tires, Proc. Sensor 99, pp. 41-46, Vol. 1, 1999
    • (1999) Proc. Sensor 99 , vol.1 , pp. 41-46
    • Budzier, H.1    Zimmerhackl, M.2    Krause, V.3    Hoven, G.4
  • 5
    • 61349178540 scopus 로고    scopus 로고
    • Heat transfer study in a rotor-stator system air-gap with an axial inflow
    • J. Pellé, S. Harmand, Heat transfer study in a rotor-stator system air-gap with an axial inflow, Applied Thermal Engineering 29 (2009), Pages 1532-1543
    • (2009) Applied Thermal Engineering , vol.29 , pp. 1532-1543
    • Pellé, J.1    Harmand, S.2
  • 6
    • 33745812406 scopus 로고    scopus 로고
    • Simulation analysis of uncertainty of infrared camera measurement and processing path
    • W. Minkina, S. Dudzik, "Simulation analysis of uncertainty of infrared camera measurement and processing path", Measurement, Volume 39 (2006.), Issue 8, Pages 758-763
    • (2006) Measurement , vol.39 , Issue.8 , pp. 758-763
    • Minkina, W.1    Dudzik, S.2
  • 7
    • 78649559835 scopus 로고    scopus 로고
    • Some Problems of Synchronous Hydro-Generator Temperature Measurement
    • Coimbra, Portugal, September
    • M. Vražić, I. Gašparac, M. Pavlica, "Some Problems of Synchronous Hydro-Generator Temperature Measurement",: A.P.D.E.E. 2008, Coimbra, Portugal, Page(s): 1-4, September 2008
    • (2008) A.P.D.E.E. 2008 , pp. 1-4
    • Vražić, M.1    Gašparac, I.2    Pavlica, M.3
  • 8
    • 78649593662 scopus 로고    scopus 로고
    • Methodology of verifying IR temperature measurement on synchronous generator in rotation
    • Dubrovnik, Croatia, (ISBN: 978-953-6037-55-1)
    • M. Vražić, S. Stipetić. M. Kutija, "Methodology of verifying IR temperature measurement on synchronous generator in rotation", EDPE 2009, Dubrovnik, Croatia, (ISBN: 978-953-6037-55-1)
    • EDPE 2009
    • Vražić, M.1    Stipetić, S.2    Kutija, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.