메뉴 건너뛰기




Volumn 128, Issue 5, 2010, Pages 3232-3238

Estimating the total ultrasound attenuation along the propagation path by using a reference phantom

Author keywords

[No Author keywords available]

Indexed keywords

12 PULSE; ARRAY TRANSDUCERS; ATTENUATION COEFFICIENT; CLINICAL SETTINGS; DIFFRACTION EFFECTS; ECHO LINES; MODIFIED ALGORITHMS; PLANAR REFLECTORS; PROPAGATION PATHS; PULSE LENGTH; RADIO FREQUENCIES; REGION OF INTEREST; SCATTERER SIZE; SINGLE ELEMENT; STANDARD DEVIATION; TISSUE MIMICKING PHANTOM; TRANSMITTED PULSE; ULTRASONIC ATTENUATION; ULTRASOUND ATTENUATION;

EID: 78649533299     PISSN: 00014966     EISSN: None     Source Type: Journal    
DOI: 10.1121/1.3483739     Document Type: Article
Times cited : (26)

References (24)
  • 1
    • 49349106819 scopus 로고    scopus 로고
    • Ultrasound attenuation estimation using backscattered echoes from multiple sources
    • 0001-4966,. 10.1121/1.2949519
    • Bigelow, T. A. (2008). " Ultrasound attenuation estimation using backscattered echoes from multiple sources.," J. Acoust. Soc. Am. 0001-4966 124, 1367-1373. 10.1121/1.2949519
    • (2008) J. Acoust. Soc. Am. , vol.124 , pp. 1367-1373
    • Bigelow, T.A.1
  • 2
    • 76049091122 scopus 로고    scopus 로고
    • Improved algorithm for estimation of attenuation along propagation path using backscattered echoes from multiple sources
    • 0041-624X,. 10.1016/j.ultras.2009.10.011
    • Bigelow, T. A. (2010a). " Improved algorithm for estimation of attenuation along propagation path using backscattered echoes from multiple sources.," Ultrasonics 0041-624X 50, 496-501. 10.1016/j.ultras.2009.10.011
    • (2010) Ultrasonics , vol.50 , pp. 496-501
    • Bigelow, T.A.1
  • 3
    • 77951039609 scopus 로고    scopus 로고
    • Estimating the total ultrasound attenuation along the propagation path by applying multiple filters to backscattered echoes from a single spherically focused source
    • 0885-3010,. 10.1109/TUFFC.2010.1494
    • Bigelow, T. A. (2010b). " Estimating the total ultrasound attenuation along the propagation path by applying multiple filters to backscattered echoes from a single spherically focused source.," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 57, 900-907. 10.1109/TUFFC.2010.1494
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , pp. 900-907
    • Bigelow, T.A.1
  • 4
    • 40749162648 scopus 로고    scopus 로고
    • In vivo ultrasonic attenuation slope estimates for detecting cervical ripening in rats: Preliminary results
    • " 0001-4966,. 10.1121/1.2832317
    • Bigelow, T. A., McFarlin, B. L., O'Brien, W. D., Jr., and Oelze, M. L. (2008). " In vivo ultrasonic attenuation slope estimates for detecting cervical ripening in rats: Preliminary results.," J. Acoust. Soc. Am. 0001-4966 123, 1794-1800. 10.1121/1.2832317
    • (2008) J. Acoust. Soc. Am. , vol.123 , pp. 1794-1800
    • Bigelow, T.A.1    McFarlin, B.L.2    O'Brien Jr., W.D.3    Oelze, M.L.4
  • 5
    • 3142772030 scopus 로고    scopus 로고
    • Scatterer size estimation in pulse-echo ultrasound using focused sources: Calibration measurements and phantom experiments
    • 0001-4966,. 10.1121/1.1757453
    • Bigelow, T. A., and O'Brien, W. D., Jr. (2004). " Scatterer size estimation in pulse-echo ultrasound using focused sources: Calibration measurements and phantom experiments.," J. Acoust. Soc. Am. 0001-4966 116, 594-602. 10.1121/1.1757453
    • (2004) J. Acoust. Soc. Am. , vol.116 , pp. 594-602
    • Bigelow, T.A.1    O'Brien Jr., W.D.2
  • 6
    • 33745759752 scopus 로고    scopus 로고
    • Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes
    • 0001-4966,. 10.1121/1.2208456
    • Bigelow, T. A., and O'Brien, W. D., Jr. (2006). " Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.," J. Acoust. Soc. Am. 0001-4966 120, 546-553. 10.1121/1.2208456
    • (2006) J. Acoust. Soc. Am. , vol.120 , pp. 546-553
    • Bigelow, T.A.1    O'Brien Jr., W.D.2
  • 7
    • 14844342757 scopus 로고    scopus 로고
    • Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms
    • " 0001-4966,. 10.1121/1.1858192
    • Bigelow, T. A., Oelze, M. L., and O'Brien, W. D., Jr. (2005). " Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms.," J. Acoust. Soc. Am. 0001-4966 117, 1431-1439. 10.1121/1.1858192
    • (2005) J. Acoust. Soc. Am. , vol.117 , pp. 1431-1439
    • Bigelow, T.A.1    Oelze, M.L.2    O'Brien Jr., W.D.3
  • 8
    • 27744447920 scopus 로고    scopus 로고
    • Temporal analysis of tissue displacement induced by a transient ultrasound radiation force
    • " 0001-4966,. 10.1121/1.2062527
    • Calĺ, S., Remenieras, J. -P., Matar, O. B., Hachemi, M. E., and Patat, F. (2005). " Temporal analysis of tissue displacement induced by a transient ultrasound radiation force.," J. Acoust. Soc. Am. 0001-4966 118, 2829-2840. 10.1121/1.2062527
    • (2005) J. Acoust. Soc. Am. , vol.118 , pp. 2829-2840
    • Calĺ, S.1    Remenieras, J.-P.2    Matar, O.B.3    Hachemi, M.E.4    Patat, F.5
  • 9
    • 0030448232 scopus 로고    scopus 로고
    • Ultrasonic measurement of glomerular diameters in normal adult humans
    • " 0301-5629,. 10.1016/S0301-5629(96)00142-1
    • Hall, T. J., Insana, M. F., Harrison, L. A., and Cox, G. G. (1996). " Ultrasonic measurement of glomerular diameters in normal adult humans.," Ultrasound Med. Biol. 0301-5629 22, 987-997. 10.1016/S0301- 5629(96)00142-1
    • (1996) Ultrasound Med. Biol. , vol.22 , pp. 987-997
    • Hall, T.J.1    Insana, M.F.2    Harrison, L.A.3    Cox, G.G.4
  • 10
    • 0022664580 scopus 로고
    • Application of stochastic analysis to ultrasonic echoes-Estimation of attenuation and tissue heterogeneity from peaks of echo envelope
    • 0001-4966,. 10.1121/1.393540
    • He, P. J. F. G. (1986). " Application of stochastic analysis to ultrasonic echoes-Estimation of attenuation and tissue heterogeneity from peaks of echo envelope.," J. Acoust. Soc. Am. 0001-4966 79, 526-534. 10.1121/1.393540
    • (1986) J. Acoust. Soc. Am. , vol.79 , pp. 526-534
    • He, P.J.F.G.1
  • 11
    • 0025066762 scopus 로고
    • Parametric ultrasound imaging from backscatter coefficient measurements: Image formation and interpretation
    • 0161-7346,. 10.1016/0161-7346(90)90002-F
    • Insana, M. F., and Hall, T. J. (1990). " Parametric ultrasound imaging from backscatter coefficient measurements: Image formation and interpretation.," Ultrason. Imaging 0161-7346 12, 245-267. 10.1016/0161-7346(90)90002-F
    • (1990) Ultrason. Imaging , vol.12 , pp. 245-267
    • Insana, M.F.1    Hall, T.J.2
  • 12
    • 0025343519 scopus 로고
    • Describing small-scale structure in random media using pulse-echo ultrasound
    • " 0001-4966,. 10.1121/1.399283
    • Insana, M. F., Wagner, R. F., Brown, D. G., and Hall, T. J. (1990). " Describing small-scale structure in random media using pulse-echo ultrasound.," J. Acoust. Soc. Am. 0001-4966 87, 179-192. 10.1121/1.399283
    • (1990) J. Acoust. Soc. Am. , vol.87 , pp. 179-192
    • Insana, M.F.1    Wagner, R.F.2    Brown, D.G.3    Hall, T.J.4
  • 13
    • 78649597744 scopus 로고
    • Analysis of a spectral difference method for measuring the slope of attenuation coefficients
    • " 0161-7346,. 10.1016/0161-7346(83)90035-4
    • Insana, M. F., Zagzebski, J. A., Madsen, E. L., and Frank, G. R. (1983). " Analysis of a spectral difference method for measuring the slope of attenuation coefficients.," Ultrason. Imaging 0161-7346 5, 173. 10.1016/0161-7346(83)90035-4
    • (1983) Ultrason. Imaging , vol.5 , pp. 173
    • Insana, M.F.1    Zagzebski, J.A.2    Madsen, E.L.3    Frank, G.R.4
  • 14
    • 0019303086 scopus 로고
    • Clinical application of an ultrasound attenuation coefficient estimation technique for liver pathology characterization
    • 0018-9294,. 10.1109/TBME.1980.326739
    • Kuc, R. (1980). " Clinical application of an ultrasound attenuation coefficient estimation technique for liver pathology characterization.," IEEE Trans. Biomed. Eng. 0018-9294 BME-27, 312-319. 10.1109/TBME.1980.326739
    • (1980) IEEE Trans. Biomed. Eng. , vol.BME-27 , pp. 312-319
    • Kuc, R.1
  • 15
    • 0020736522 scopus 로고
    • Theoretical framework for spectrum analysis in ultrasonic tissue characterization
    • " 0001-4966,. 10.1121/1.389241
    • Lizzi, F. L., Greenebaum, M., Feleppa, E. J., Elbaum, M., and Coleman, D. J. (1983). " Theoretical framework for spectrum analysis in ultrasonic tissue characterization.," J. Acoust. Soc. Am. 0001-4966 73, 1366-1373. 10.1121/1.389241
    • (1983) J. Acoust. Soc. Am. , vol.73 , pp. 1366-1373
    • Lizzi, F.L.1    Greenebaum, M.2    Feleppa, E.J.3    Elbaum, M.4    Coleman, D.J.5
  • 16
    • 2942609260 scopus 로고    scopus 로고
    • Differentiation and characterization of rat mammary fibroadenomas and 4T1 mouse carcinomas using quantitative ultrasound imaging
    • " 0278-0062,. 10.1109/TMI.2004.826953
    • Oelze, M. L., O'Brien, W. D., Jr., Blue, J. P., and Zachary, J. F. (2004). " Differentiation and characterization of rat mammary fibroadenomas and 4T1 mouse carcinomas using quantitative ultrasound imaging.," IEEE Trans. Med. Imaging 0278-0062 23, 764-771. 10.1109/TMI.2004.826953
    • (2004) IEEE Trans. Med. Imaging , vol.23 , pp. 764-771
    • Oelze, M.L.1    O'Brien Jr., W.D.2    Blue, J.P.3    Zachary, J.F.4
  • 18
    • 33746903090 scopus 로고    scopus 로고
    • An investigation of the use of transmission ultrasound to measure acoustic attenuation changes in thermal therapy
    • 10.1007/s11517-006-0067-8
    • Parmar, N, and Kolios, M. (2006). " An investigation of the use of transmission ultrasound to measure acoustic attenuation changes in thermal therapy.," Med. Biol. Eng. Comput. 44, 583-591. 10.1007/s11517-006-0067-8
    • (2006) Med. Biol. Eng. Comput. , vol.44 , pp. 583-591
    • Parmar, N.1    Kolios, M.2
  • 20
    • 0026070435 scopus 로고
    • Forces acting in the direction of propagation in pulsed ultrasound fields
    • " 0031-9155,. 10.1088/0031-9155/36/11/006
    • Starritt, H. C., Duck, F. A., and Humphrey, V. F. (1991). " Forces acting in the direction of propagation in pulsed ultrasound fields.," Phys. Med. Biol. 0031-9155 36, 1465-1474. 10.1088/0031-9155/36/11/006
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1465-1474
    • Starritt, H.C.1    Duck, F.A.2    Humphrey, V.F.3
  • 21
    • 32844470955 scopus 로고    scopus 로고
    • Ultrasound attenuation measurement in the presence of scatterer variation for reduction of shadowing and enhancement
    • " 0885-3010,. 10.1109/TUFFC.2005.1563279
    • Treece, G., Prager, R., and Gee, A. (2005). " Ultrasound attenuation measurement in the presence of scatterer variation for reduction of shadowing and enhancement.," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 52, 2346-2360. 10.1109/TUFFC.2005.1563279
    • (2005) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.52 , pp. 2346-2360
    • Treece, G.1    Prager, R.2    Gee, A.3
  • 22
    • 33644829420 scopus 로고    scopus 로고
    • Attenuation estimations using envelope echo data: Analysis and simulations
    • " 0301-5629,. 10.1016/j.ultrasmedbio.2005.12.001
    • Tu, H., Zagzebski, J., and Chen, Q. (2006). " Attenuation estimations using envelope echo data: Analysis and simulations.," Ultrasound Med. Biol. 0301-5629 32, 377-386. 10.1016/j.ultrasmedbio.2005.12.001
    • (2006) Ultrasound Med. Biol. , vol.32 , pp. 377-386
    • Tu, H.1    Zagzebski, J.2    Chen, Q.3
  • 23
    • 0036827068 scopus 로고    scopus 로고
    • A Gaussian framework for modeling effects of frequency-dependent attenuation, frequency-dependent scattering, and gating
    • 0885-3010,. 10.1109/TUFFC.2002.1049739
    • Wear, K. A. (2002). " A Gaussian framework for modeling effects of frequency-dependent attenuation, frequency-dependent scattering, and gating.," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 49, 1572-1582. 10.1109/TUFFC.2002.1049739
    • (2002) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.49 , pp. 1572-1582
    • Wear, K.A.1
  • 24
    • 0025230571 scopus 로고
    • Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors
    • " 0161-7346,. 10.1016/0161-7346(90)90221-I
    • Yao, L. X., Zagzebski, J. A., and Madsen, E. L. (1990). " Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors.," Ultrason. Imaging 0161-7346 12, 58-70. 10.1016/0161-7346(90)90221-I
    • (1990) Ultrason. Imaging , vol.12 , pp. 58-70
    • Yao, L.X.1    Zagzebski, J.A.2    Madsen, E.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.