메뉴 건너뛰기




Volumn 15, Issue 1, 2010, Pages 98-103

Direct versus video laryngoscopic intubation by novice prehospital intubators with and without chest compressions: A pilot manikin study

Author keywords

chest compression; tracheal intubation; video laryngoscope

Indexed keywords


EID: 78649519484     PISSN: 10903127     EISSN: 15450066     Source Type: Journal    
DOI: 10.3109/10903127.2010.514087     Document Type: Article
Times cited : (33)

References (30)
  • 1
    • 26044479492 scopus 로고    scopus 로고
    • Yealy DM.Defining the learning curve for paramedic student endotracheal intubation
    • Wang HE, Seitz SR,Hostler D, Yealy DM.Defining the learning curve for paramedic student endotracheal intubation. Prehosp Emerg Care. 2005;9:156-62.
    • (2005) Prehosp. Emerg. Care. , vol.9 , pp. 156-162
    • Wang, H.E.1    Seitz, S.R.2    Hostler, D.3
  • 2
    • 77749313423 scopus 로고    scopus 로고
    • Use of video laryngoscopy in a ground EMS system: Better for you better for your patients
    • Wayne M. Use of video laryngoscopy in a ground EMS system: better for you, better for your patients. JEMS. 2008;33 (9 suppl):11-3.
    • (2008) JEMS , vol.33 , Issue.9 , pp. 11-13
    • Wayne, M.1
  • 3
    • 50449103551 scopus 로고    scopus 로고
    • Prehospital use of video laryngoscope by an air medical crew
    • Bjoernsen LP, Parquette BT, Lindsay MB. Prehospital use of video laryngoscope by an air medical crew. Air Med J. 2008;27:242-4.
    • (2008) Air. Med. J. , vol.27 , pp. 242-244
    • Bjoernsen, L.P.1    Parquette, B.T.2    Lindsay, M.B.3
  • 4
    • 70350630430 scopus 로고    scopus 로고
    • Video laryngoscopy with the Macintosh video laryngoscope in simulated prehospital scenarios by paramedic students
    • Aziz M, Dillman D, Kirsch JR, Brambrink A. Video laryngoscopy with the Macintosh video laryngoscope in simulated prehospital scenarios by paramedic students. Prehosp Emerg Care. 2009;13:251-5.
    • (2009) Prehosp. Emerg. Care. , vol.13 , pp. 251-255
    • Aziz, M.1    Dillman, D.2    Kirsch, J.R.3    Brambrink, A.4
  • 5
    • 70349731753 scopus 로고    scopus 로고
    • The GlideScope Ranger video laryngoscope can be useful in airway management of entrapped patients
    • Nakstad AR, Sandberg M. The GlideScope Ranger video laryngoscope can be useful in airway management of entrapped patients. Acta Anaesthesiol Scand. 2009;53:1257-61.
    • (2009) Acta. Anaesthesiol Scand. , vol.53 , pp. 1257-1261
    • Nakstad, A.R.1    Sandberg, M.2
  • 6
    • 34247263831 scopus 로고    scopus 로고
    • A throat with a view. Innovative video laryngoscope gives you a new angle
    • Hildwine F. A throat with a view. Innovative video laryngoscope gives you a new angle. JEMS. 2007;32(2):86.
    • (2007) JEMS , vol.32 , Issue.2 , pp. 86
    • Hildwine, F.1
  • 7
    • 85047696151 scopus 로고    scopus 로고
    • Description and first clinical application of Airway Scope for tracheal intubation
    • Koyama J, Aoyama T, Kusano Y, et al. Description and first clinical application of Airway Scope for tracheal intubation. J Neurosurg Anesthsiol. 2006;18:247-50.
    • (2006) J. Neurosurg. Anesthsiol. , vol.18 , pp. 247-250
    • Koyama, J.1    Aoyama, T.2    Kusano, Y.3
  • 8
    • 3042821019 scopus 로고    scopus 로고
    • Ease of intubationwith the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways
    • Lim Y, Lim TJ, Liu EHC. Ease of intubationwith the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways. Can J Anaesth. 2004;51:641-2.
    • (2004) Can. J. Anaesth. , vol.51 , pp. 641-642
    • Lim, Y.1    Lim, T.J.2    Liu, E.H.C.3
  • 9
    • 35348943433 scopus 로고    scopus 로고
    • Evaluation of the airway scope a new video laryngoscope in tracheal intubation by naive operators: A manikin study
    • Miki T, Inagawa G, Kikuchi T, Koyama Y, Goto T. Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naive operators: a manikin study. Acta Anaesthesiol Scand. 2007;51:1378-81.
    • (2007) Acta. Anaesthesiol Scand. , vol.51 , pp. 1378-1381
    • Miki, T.1    Inagawa, G.2    Kikuchi, T.3    Koyama, Y.4    Goto, T.5
  • 10
    • 59449095966 scopus 로고    scopus 로고
    • Ease of intubation with the GlideScope or Airway Scope by novice operators in simulated easy and difficult airways - A manikin study
    • Tan BH, Liu EH, Lim RT, Liow LM, Goy RW. Ease of intubation with the GlideScope or Airway Scope by novice operators in simulated easy and difficult airways-a manikin study. Anaesthesia. 2009;64:187-90.
    • (2009) Anaesthesia , vol.64 , pp. 187-190
    • Tan, B.H.1    Liu, E.H.2    Lim, R.T.3    Liow, L.M.4    Goy, R.W.5
  • 11
    • 70350198059 scopus 로고    scopus 로고
    • A comparison of the Glidescope pentax Aws and macintosh laryngoscopes when usedby novice personnel: A manikin study
    • Malik MA, Hassett P, Carney J, Higgins BD, Harte BH, Laffey JG. A comparison of the Glidescope, Pentax AWS, and Macintosh laryngoscopes when usedby novice personnel: a manikin study. Can J Anaesth. 2009;56:802-11.
    • (2009) Can. J. Anaesth. , vol.56 , pp. 802-811
    • Malik, M.A.1    Hassett, P.2    Carney, J.3    Higgins, B.D.4    Harte, B.H.5    Laffey, J.G.6
  • 12
    • 41349103407 scopus 로고    scopus 로고
    • Video laryngoscopy for emergency tracheal intubation during chest compression
    • Sadamori T, Kusunoki S, Ishida M, Otani T, Tanigawa K. Video laryngoscopy for emergency tracheal intubation during chest compression. Resuscitation. 2008;77:155-6.
    • (2008) Resuscitation , vol.77 , pp. 155-156
    • Sadamori, T.1    Kusunoki, S.2    Ishida, M.3    Otani, T.4    Tanigawa, K.5
  • 13
    • 72049107444 scopus 로고    scopus 로고
    • Utility of the Pentax-AWS R without interruption of chest compression: Comparison of the Macintosh laryngoscopewith the Pentax-AWS R in manikinmodel
    • Han SK, Shin DH, Choi PC. Utility of the Pentax-AWS R- without interruption of chest compression: comparison of the Macintosh laryngoscopewith the Pentax-AWS R- in manikinmodel. Resuscitation. 2010;81:69-73.
    • (2010) Resuscitation , vol.81 , pp. 69-73
    • Han, S.K.1    Shin, D.H.2    Choi, P.C.3
  • 14
    • 77955484360 scopus 로고    scopus 로고
    • Airway Scope vs. Macintosh laryngoscope during chest compressions on a fresh cadaver model
    • Cho J, Chung HS, Chung SP, Kim YM, Cho YS. Airway Scope vs. Macintosh laryngoscope during chest compressions on a fresh cadaver model. Am J Emerg Med. 2010;28: 741-1.
    • (2010) Am. J. Emerg. Med. , vol.28 , pp. 741-751
    • Cho, J.1    Chung, H.S.2    Chung, S.P.3    Kim, Y.M.4    Cho, Y.S.5
  • 15
    • 33744804035 scopus 로고    scopus 로고
    • 2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care part 4: Adult basic life support
    • 2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 4: Adult basic life support. Circulation. 2005;112:IV19-IV34.
    • (2005) Circulation , vol.112
  • 16
    • 40949105091 scopus 로고    scopus 로고
    • Effect of chest compressions on the time taken to insert airway devices in a manikin
    • Gatward JJ, Thomas MJ, Nolan JP, Cook TM. Effect of chest compressions on the time taken to insert airway devices in a manikin. Br J Anaesth. 2008;100:351-6.
    • (2008) Br. J. Anaesth. , vol.100 , pp. 351-356
    • Gatward, J.J.1    Thomas, M.J.2    Nolan, J.P.3    Cook, T.M.4
  • 17
    • 0034702861 scopus 로고    scopus 로고
    • American Heart Association guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care. part 6: Advanced cardiovascular life support: section 3: adjuncts for oxygenation ventilation and airway control
    • . American Heart Association guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care. Part 6: Advanced cardiovascular life support: section 3: adjuncts for oxygenation, ventilation, and airway control. Circulation. 2000;102(8 suppl):I95-I104.
    • (2000) Circulation , vol.102 , Issue.8
  • 18
    • 28444490018 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2005 section 4 adult for resuscitation advanced life support
    • Nolan JP, Deakin CD, Soar J, Bottiger BW, Smith G. European Resuscitation Council guidelines for resuscitation 2005. Section 4. Adult for resuscitation advanced life support. Resuscitation. 2005; 67(suppl 1):S39-S86.
    • (2005) Resuscitation , vol.67 , Issue.1
    • Nolan, J.P.1    Deakin, C.D.2    Soar, J.3    Bottiger, B.W.4    Smith, G.5
  • 19
    • 0035856551 scopus 로고    scopus 로고
    • Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest
    • Berg RA, Sanders AB, Kern KB, et al. Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest. Circulation. 2001;104: 2465-70.
    • (2001) Circulation , vol.104 , pp. 2465-2470
    • Berg, R.A.1    Sanders, A.B.2    Kern, K.B.3
  • 20
    • 67349214792 scopus 로고    scopus 로고
    • 2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 7.1: Adjuncts for airway control and ventilation
    • 2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 7.1: Adjuncts for airway control and ventilation. Circulation. 2005;112:IV84-IV88.
    • (2005) Circulation , vol.112
  • 21
    • 0022403962 scopus 로고
    • Prehospital endotracheal intubation: Rationale for training emergency medical personnel
    • Pepe PE, Copass MK, Joyce TH. Prehospital endotracheal intubation: rationale for training emergency medical personnel. Ann Emerg Med. 1985;14:1085-92.
    • (1985) Ann. Emerg. Med. , vol.14 , pp. 1085-1092
    • Pepe, P.E.1    Copass, M.K.2    Joyce, T.H.3
  • 22
    • 70350048929 scopus 로고    scopus 로고
    • Interruptions in cardiopulmonary resuscitation from paramedic endotracheal intubation
    • Wang HE, Simeone SJ, Weaver MD, Callaway CW. Interruptions in cardiopulmonary resuscitation from paramedic endotracheal intubation. Ann Emerg Med. 2009;54:645-52.
    • (2009) Ann. Emerg. Med. , vol.54 , pp. 645-652
    • Wang, H.E.1    Simeone, S.J.2    Weaver, M.D.3    Callaway, C.W.4
  • 23
    • 43749119189 scopus 로고    scopus 로고
    • Optical and video laryngoscopes for emergency airway management
    • Sakles JC, Rodgers R, Keim SM. Optical and video laryngoscopes for emergency airway management. Intern Emerg Med. 2008;3:139-43.
    • (2008) Intern. Emerg. Med. , vol.3 , pp. 139-143
    • Sakles, J.C.1    Rodgers, R.2    Keim, S.M.3
  • 24
    • 16344374081 scopus 로고    scopus 로고
    • Early clinical experience with a new videolaryngoscope GlideScope R in 728 patients
    • Cooper RM, Pacey JA, Bishop MJ, McCluskey SA. Early clinical experience with a new videolaryngoscope (GlideScope R) in 728 patients. Can J Anaesth. 2005;52:191-8.
    • (2005) Can. J. Anaesth. , vol.52 , pp. 191-198
    • Cooper, R.M.1    Pacey, J.A.2    Bishop, M.J.3    Mc Cluskey, S.A.4
  • 26
    • 77449105751 scopus 로고    scopus 로고
    • Management of the predicted difficult airway: A comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the glidescope
    • Serocki G, Bein B, Scholz J, Dörges V. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. Eur J Anaesthesiol. 2010;27:24-30.
    • (2010) Eur. J. Anaesthesiol. , vol.27 , pp. 24-30
    • Serocki, G.1    Bein, B.2    Scholz, J.3    Dörges, V.4
  • 27
    • 33745018618 scopus 로고    scopus 로고
    • Learning and performance of tracheal intubation by novice personnel: A comparison of the airtraq and macintosh laryngoscope
    • Maharaj CH, Costello JF, Higgins BD, Harte BH, Laffey JG. Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq and Macintosh laryngoscope. Anaesthesia. 2006;61:671-7.
    • (2006) Anaesthesia , vol.61 , pp. 671-677
    • Maharaj, C.H.1    Costello, J.F.2    Higgins, B.D.3    Harte, B.H.4    Laffey, J.G.5
  • 29
    • 41949120312 scopus 로고    scopus 로고
    • Pentax- AWS, a new videolaryngoscope, is more effective than the macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: A randomized comparative study
    • Enomoto Y, Asai T, Arai T, Kamishima K, Okuda Y. Pentax- AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth. 2008;100:544-8.
    • (2008) Br. J. Anaesth. , vol.100 , pp. 544-548
    • Enomoto, Y.1    Asai, T.2    Arai, T.3    Kamishima, K.4    Okuda, Y.5
  • 30
    • 74949099834 scopus 로고    scopus 로고
    • Randomized controlled trial of the pentax aws glidescope and macintosh laryngoscopes in predicted difficult intubation
    • Malik MA, Subramaniam R, Maharaj CH, Harte BH, Laffey JG. Randomized controlled trial of the Pentax AWS, GlideScope, and Macintosh laryngoscopes in predicted difficult intubation. Br J Anaesth. 2009;103:761-8.
    • (2009) Br. J. Anaesth. , vol.103 , pp. 761-768
    • Malik, M.A.1    Subramaniam, R.2    Maharaj, C.H.3    Harte, B.H.4    Laffey, J.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.