메뉴 건너뛰기




Volumn 60, Issue 5, 2010, Pages 374-379

Morphometric comparison of the lumbar cancellous bone of sheep, deer, and humans

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANIMAL TISSUE; ANISOTROPY; ARTICLE; BONE MASS; CANCELLOUS BONE; COMPARATIVE STUDY; DEER; FEMALE; HUMAN; HUMAN TISSUE; LUMBAR SPINE; MALE; MORPHOMETRICS; NONHUMAN; POROSITY; SHEEP; TRABECULAR BONE;

EID: 78649425651     PISSN: 15320820     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (32)
  • 1
    • 0035047067 scopus 로고    scopus 로고
    • Inhomogeneity of human vertebral cancellous bone: Systematic desity and structure patterns inside the vertebral body
    • Banse X, Devogelaer JP, Munting E, Delloye C, Cornu O, Grynpas M. 2001. Inhomogeneity of human vertebral cancellous bone: systematic desity and structure patterns inside the vertebral body. Bone 28:563-571.
    • (2001) Bone , vol.28 , pp. 563-571
    • Banse, X.1    Devogelaer, J.P.2    Munting, E.3    Delloye, C.4    Cornu, O.5    Grynpas, M.6
  • 2
    • 0033830766 scopus 로고    scopus 로고
    • Titanium alloy enhances bone-pedicle screw fixation: Mechanical histomorphometrical results of titanium alloy versus stainless steel
    • Christensen FB, Dalstra M, Sejling F, Overgaard S, Bünger C. 2000. Titanium alloy enhances bone-pedicle screw fixation: mechanical histomorphometrical results of titanium alloy versus stainless steel. Eur Spine J 9:97-103.
    • (2000) Eur Spine J , vol.9 , pp. 97-103
    • Christensen, F.B.1    Dalstra, M.2    Sejling, F.3    Overgaard, S.4    Bünger, C.5
  • 4
    • 0022672008 scopus 로고
    • Wolff's law of trabecular architecture at remodeling equilibrium
    • Cowin SC. 1986. Wolff's law of trabecular architecture at remodeling equilibrium. J Biomech Eng 108:83-88.
    • (1986) J Biomech Eng , vol.108 , pp. 83-88
    • Cowin, S.C.1
  • 6
    • 0021880663 scopus 로고
    • The mechanical behaviour of cancellous bone
    • Gibson LJ. 1985. The mechanical behaviour of cancellous bone. J Biomech 18:317-328.
    • (1985) J Biomech , vol.18 , pp. 317-328
    • Gibson, L.J.1
  • 7
    • 0031706325 scopus 로고    scopus 로고
    • Image-based assessment of spinal trabecular bone structure from high-resolution CT images
    • DOI 10.1007/s001980050070
    • Gordon CL, Lang TF, Augat P, Genant HK. 1998. Image-based assessment of spinal trabecular bone structure from high-resolution CT images. Osteoporos Int 8:317-325. (Pubitemid 28418265)
    • (1998) Osteoporosis International , vol.8 , Issue.4 , pp. 317-325
    • Gordon, C.L.1    Lang, T.F.2    Augat, P.3    Genant, H.K.4
  • 8
    • 0029933445 scopus 로고    scopus 로고
    • In vivo assessment of trabecular bone structure at the distal radius from high-resolution computed tomography image
    • Gordon CL, Webber CE, Adachi JD, Christoforou N. 1996. In vivo assessment of trabecular bone structure at the distal radius from high-resolution computed tomography image. Phys Med Biol 41:495-508.
    • (1996) Phys Med Biol , vol.41 , pp. 495-508
    • Gordon, C.L.1    Webber, C.E.2    Adachi, J.D.3    Christoforou, N.4
  • 9
    • 0033047422 scopus 로고    scopus 로고
    • Direct 3-dimensional morphometric analysis of human cancellous bone: Microstructural data from spine, femur, iliac crest, and calcaneus
    • Hildebrand T, Laib A, Müller R, Dequeker J, Rüegseger P. 1999. Direct 3-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J Bone Miner Res 14:1167-1174.
    • (1999) J Bone Miner Res , vol.14 , pp. 1167-1174
    • Hildebrand, T.1    Laib, A.2    Müller, R.3    Dequeker, J.4    Rüegseger, P.5
  • 10
    • 0028258422 scopus 로고
    • Three-dimensional photographic study of cancellous bone in human fourth lumbar vertebral bodies
    • Jayasinghe JA, Jones SJ, Boyde A. 1994. Three-dimensional photographic study of cancellous bone in human fourth lumbar vertebral bodies. Anat Embryol (Berl) 189:259-274. (Pubitemid 24105645)
    • (1994) Anatomy and Embryology , vol.189 , Issue.3 , pp. 259-274
    • Jayasinghe, J.A.P.1    Jones, S.J.2    Boyde, A.3
  • 11
    • 0031723123 scopus 로고    scopus 로고
    • Trabecular bone mineral and calculated structure of human bone specimens scanned by peripheral quantitative computed tomography: Relation to biomechanical properties
    • DOI 10.1359/jbmr.1998.13.11.1783
    • Jiang Y, Zhao J, Augat P, Ouyang X, Lu Y, Majumdar S, Genant HK. 1998. Trabecular born mineral and calculated structure of human bone specimens scanned by peripheral quantitative computed tomography: relation to biomechanical properties. J Bone Miner Res 13:1783-1790. (Pubitemid 28492010)
    • (1998) Journal of Bone and Mineral Research , vol.13 , Issue.11 , pp. 1783-1790
    • Jiang, Y.1    Zhao, J.2    Augat, P.3    Ouyang, X.4    Lu, Y.5    Majumdar, S.6    Genant, H.K.7
  • 12
    • 65449148662 scopus 로고    scopus 로고
    • Variation of trabecular microzrchitectural parameters in cranial, caudal, and midvertebral regions of the ovine L3 vertebra
    • Kennedy OD, Brennan O, Rackard SM, O'Brien FJ, Taylor D, Lee TC. 2009. Variation of trabecular microzrchitectural parameters in cranial, caudal, and midvertebral regions of the ovine L3 vertebra. J Anat 214:729-735.
    • (2009) J Anat , vol.214 , pp. 729-735
    • Kennedy, O.D.1    Brennan, O.2    Rackard, S.M.3    O'Brien, F.J.4    Taylor, D.5    Lee, T.C.6
  • 13
    • 37249067082 scopus 로고    scopus 로고
    • Are the spines of calf, pig, and sheep suitable models for preclinical implant tests?
    • Kettler A, Liakos L, Haegele B, Wilke HJ. 2007. Are the spines of calf, pig, and sheep suitable models for preclinical implant tests? Eur Spine J 16:2186-2192.
    • (2007) Eur Spine J , vol.16 , pp. 2186-2192
    • Kettler, A.1    Liakos, L.2    Haegele, B.3    Wilke, H.J.4
  • 14
    • 0034307425 scopus 로고    scopus 로고
    • Anatomy of deer spine and its comparison to the human spine
    • Kumar N, Kukreti S, Ishaque M, Mulholland R. 2000. Anatomy of deer spine and its comparison to the human spine. Anat Rec 260:189-203.
    • (2000) Anat Rec , vol.260 , pp. 189-203
    • Kumar, N.1    Kukreti, S.2    Ishaque, M.3    Mulholland, R.4
  • 15
    • 0036468357 scopus 로고    scopus 로고
    • Functional anatomy of the deer spine:an appropriate biomechanical model for the human spine?
    • Kumar N, Kukreti S, Kukreti S, Ishaque M, Sengupta DK, Mulholland RC. 2002. Functional anatomy of the deer spine:an appropriate biomechanical model for the human spine? Anat Rec 266:108-117.
    • (2002) Anat Rec , vol.266 , pp. 108-117
    • Kumar, N.1    Kukreti, S.2    Kukreti, S.3    Ishaque, M.4    Sengupta, D.K.5    Mulholland, R.C.6
  • 17
    • 78649436402 scopus 로고
    • People's Republic of China Ministry of Health. Beijing (China): Ministry of Health
    • People's Republic of China Ministry of Health. 1989. Administrative rules of experimental animals. Beijing (China): Ministry of Health.
    • (1989) Administrative Rules of Experimental Animals
  • 18
    • 78649423820 scopus 로고
    • People's Republic of China Ministry of Health. Beijing (China): Ministry of Health
    • People's Republic of China Ministry of Health. 1994. Regulations for medical institutions. Beijing (China): Ministry of Health.
    • (1994) Regulations for Medical Institutions
  • 19
    • 78649401998 scopus 로고
    • People's Republic of China National Science and Technology Committee. Beijing (China): State Science and Technology Commission
    • People's Republic of China National Science and Technology Committee. 1988. The regulations of experimental animals. Beijing (China): State Science and Technology Commission.
    • (1988) The Regulations of Experimental Animals
  • 20
    • 78649406812 scopus 로고    scopus 로고
    • People's Republic of China National Science and Technology Committee. Beijing (China): State Science and Technology Commission
    • People's Republic of China National Science and Technology Committee. 1997. Experimental animals national standards. Beijing (China): State Science and Technology Commission.
    • (1997) Experimental Animals National Standards
  • 21
    • 78649438215 scopus 로고
    • People's Republic of China National Standards. Beijing (China): State Science and Technology Commission
    • People's Republic of China National Standards. 1995. Publishing house of China standards: experimental animals national standards. Beijing (China): State Science and Technology Commission.
    • (1995) Publishing House of China Standards: Experimental Animals National Standards
  • 22
    • 78649396031 scopus 로고    scopus 로고
    • People's Republic of China State Department Beijing (China): State Council
    • People's Republic of China State Department 2004. Regulations for biosafety of pathogenic laboratories. Beijing (China): State Council.
    • (2004) Regulations for Biosafety of Pathogenic Laboratories
  • 23
    • 0034885957 scopus 로고    scopus 로고
    • Hydroxyapatite coating enhances fixation of loaded pedicle screws: A mechanical in vivo study in sheep
    • DOI 10.1007/s005860100291
    • Sandén B, Olerud C, Larsson C. 2001. Hydroxyapatite coating enhances fixation of loaded pedicle screws: a mechanical in vivo study in sheep. Eur Spine J 10:334-339. (Pubitemid 32762779)
    • (2001) European Spine Journal , vol.10 , Issue.4 , pp. 334-339
    • Sanden, B.1    Olerud, C.2    Larsson, S.3
  • 25
    • 0013864447 scopus 로고
    • Factors affecting the determination of the physical properties of the femoral cortical bone
    • Sedlin ED, Hirsch C. 1966. Factors affecting the determination of the physical properties of the femoral cortical bone. Acta Orthop Scand 37:29-48.
    • (1966) Acta Orthop Scand , vol.37 , pp. 29-48
    • Sedlin, E.D.1    Hirsch, C.2
  • 26
    • 43649104211 scopus 로고    scopus 로고
    • Detection of bone graft failure in lumbar spondylodesis: Spatial esolution with high-resolution peripheral quantitative CT
    • Strohm PC, Kubosch D, Bley TA, Sprecher CM, Südkamp NP, Milz S. 2008. Detection of bone graft failure in lumbar spondylodesis: spatial esolution with high-resolution peripheral quantitative CT Am J Roentgenol 190:1255-1259.
    • (2008) Am J Roentgenol , vol.190 , pp. 1255-1259
    • Strohm, P.C.1    Kubosch, D.2    Bley, T.A.3    Sprecher, C.M.4    Südkamp, N.P.5    Milz, S.6
  • 27
    • 78649440090 scopus 로고    scopus 로고
    • Quantitative imaging analysis of lumbar vertebral trbecular architecture with high resolution CT
    • Tan J, Wan WP, Zhou XH, Xu JW, Jia LS. 2001. Quantitative imaging analysis of lumbar vertebral trbecular architecture with high resolution CT. Orthop J Chin 8(8):780-782.
    • (2001) Orthop J Chin , vol.8 , Issue.8 , pp. 780-782
    • Tan, J.1    Wan, W.P.2    Zhou, X.H.3    Xu, J.W.4    Jia, L.S.5
  • 30
    • 0030941203 scopus 로고    scopus 로고
    • Anatomy of the sheep spine and its comparison to the human spine
    • DOI 10.1002/(SICI)1097-0185(199704)247:4<542::AID-AR13>3.0.CO;2-P
    • Wilke HJ, Kettler A, Wenger KH. 1997. Anatomy of the sheep spine and its comparison to the human spine. Anat Rec 247:542-555. (Pubitemid 27157430)
    • (1997) Anatomical Record , vol.247 , Issue.4 , pp. 542-555
    • Wilke, H.-J.1    Kettler, A.2    Wenger, K.H.3    Claes, L.E.4
  • 31
    • 33646465442 scopus 로고    scopus 로고
    • Hydroxyapatite dip coated and uncoated titanium polyaxial pedicle screws: An in vivo bovine model
    • Yildirim OS, Aksakal B, Hanyaloglu SC, Erdogan F, Okur A. 2006. Hydroxyapatite dip coated and uncoated titanium polyaxial pedicle screws: an in vivo bovine model. Spine 31:E215-E220.
    • (2006) Spine , vol.31
    • Yildirim, O.S.1    Aksakal, B.2    Hanyaloglu, S.C.3    Erdogan, F.4    Okur, A.5
  • 32
    • 55049140548 scopus 로고    scopus 로고
    • Biomechanical analysis of spinal implants
    • Zhao ZD. 2008. Biomechanical analysis of spinal implants. J Clin Rehab Tissue Eng Res 12(35):6915-6918.
    • (2008) J Clin Rehab Tissue Eng Res , vol.12 , Issue.35 , pp. 6915-6918
    • Zhao, Z.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.