메뉴 건너뛰기




Volumn 11, Issue 10, 2010, Pages

The role of echocardiography in diagnosis, monitoring closure and post-procedural assessment of patent foramen ovale

Author keywords

Echocardiography; Patent foramen ovale; Stroke

Indexed keywords

HUMAN; INTRACARDIAC ECHOCARDIOGRAPHY; MONITORING; PATENT FORAMEN OVALE; PRIORITY JOURNAL; REVIEW; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; TREATMENT OUTCOME;

EID: 78649368570     PISSN: 15252167     EISSN: 15322114     Source Type: Journal    
DOI: 10.1093/ejechocard/jeq120     Document Type: Review
Times cited : (33)

References (38)
  • 1
    • 23844547935 scopus 로고    scopus 로고
    • Patent foramen ovale and stroke
    • Homma S, Sacco RL. Patent foramen ovale and stroke. Circulation 2005;112: 1063-72.
    • (2005) Circulation , vol.112 , pp. 1063-72
    • Homma, S.1    Sacco, R.L.2
  • 3
    • 0030058821 scopus 로고    scopus 로고
    • Patent foramen ovale: association between the degree of shunt by contrast transesopha-geal echocardiographyand the riskof future ischemic neurologic events
    • Stone DA, Godard J, Corretti MC, Kittner SJ, Sample C, Price TR et al. Patent foramen ovale: association between the degree of shunt by contrast transesopha-geal echocardiographyand the riskof future ischemic neurologic events. Am Heart J 1996;131:158-61.
    • (1996) Am Heart J , vol.131 , pp. 158-61
    • Stone, D.A.1    Godard, J.2    Corretti, M.C.3    Kittner, S.J.4    Sample, C.5    Price, T.R.6
  • 4
    • 3042709663 scopus 로고    scopus 로고
    • Persisting eustachian valve in adults: Relation to
    • patent foramen ovale and cerebrovascular events
    • Schuchlenz HW, Saurer G, Weihs W, Rehak P. Persisting eustachian valve in adults: relation to patent foramen ovale and cerebrovascular events. J Am Soc Echocardiogr 2004;17:231-3.
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 231-3
    • Schuchlenz, H.W.1    Saurer, G.2    Weihs, W.3    Rehak, P.4
  • 6
    • 0035833927 scopus 로고    scopus 로고
    • Prognosis after percutaneous closure of patent foramen ovale for paradoxical embolism
    • Wahl A, Meier B, Haxel B, Nedeltchev K, Arnold M, Eicher E et al. Prognosis after percutaneous closure of patent foramen ovale for paradoxical embolism. Neurol-ogy 2001;57:1330-2.
    • (2001) Neurology , vol.57 , pp. 1330-2
    • Wahl, A.1    Meier, B.2    Haxel, B.3    Nedeltchev, K.4    Arnold, M.5    Eicher, E.6
  • 8
    • 1642461456 scopus 로고    scopus 로고
    • Transcatheter closure versus medical therapy of patent foramen ovale and presumed paradoxical thromboemboli: A systematic review
    • Khairy P, O'Donnell CP, Landzberg MJ. Transcatheter closure versus medical therapy of patent foramen ovale and presumed paradoxical thromboemboli: a systematic review. Ann Intern Med 2003;139:753-60.
    • (2003) Ann Intern Med , vol.139 , pp. 753-60
    • Khairy, P.1    O'Donnell, C.P.2    Landzberg, M.J.3
  • 9
    • 0029931512 scopus 로고    scopus 로고
    • Diag-nosis of patent foramen ovale by transesophageal echocardiography and corre-lation with autopsyfindings
    • Schneider B, Zienkiewicz T,Jansen V, Hofmann T, Noltenius H, Meinertz T. Diag-nosis of patent foramen ovale by transesophageal echocardiography and corre-lation with autopsyfindings. Am J Cardiol 1996;77:1202-9.
    • (1996) Am J Cardiol , vol.77 , pp. 1202-9
    • Schneider, B.1    Zienkiewicz, T.2    Jansen, V.3    Hofmann, T.4    Noltenius, H.5    Meinertz, T.6
  • 10
    • 11044221169 scopus 로고    scopus 로고
    • Second harmonic transthoracic echocardiography: The new reference screening method for the detection of
    • patent foramen ovale
    • Daniels C, Weytjens C, Cosyns B, Schoors D, De Sutter J, Paelinck B et al. Second harmonic transthoracic echocardiography: the new reference screening method for the detection of patent foramen ovale. Eur J Echocardiogr 2004;5:449-52.
    • (2004) Eur J Echocardiogr , vol.5 , pp. 449-52
    • Daniels, C.1    Weytjens, C.2    Cosyns, B.3    Schoors, D.4    De Sutter, J.5    Paelinck, B.6
  • 11
    • 2942661375 scopus 로고    scopus 로고
    • Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts
    • Clarke NR, Timperley J, Kelion AD, Banning AP. Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts. Eur J Echocardiogr 2004;5:176-81.
    • (2004) Eur J Echocardiogr , vol.5 , pp. 176-81
    • Clarke, N.R.1    Timperley, J.2    Kelion, A.D.3    Banning, A.P.4
  • 12
    • 0035283014 scopus 로고    scopus 로고
    • Enhanced detection of right-to-left shunt through
    • patent foramen ovale by transthoracic contrast echo-cardiography using harmonic imaging A11
    • Ha JW, Shin MS, Kang S, Pyun WB,Jang KJ, Byun KH et al. Enhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echo-cardiography using harmonic imaging. Am J Cardiol 2001;87:669-71, A11.
    • (2001) Am J Cardiol , vol.87 , pp. 669-71
    • Ha, J.W.1    Shin, M.S.2    Kang, S.3    Pyun Wbjang, K.J.4    Byun, K.H.5
  • 13
    • 33749179497 scopus 로고    scopus 로고
    • Comparison oftransthoracic echocardiographywith har-monic imaging with transoesophageal echocardiography for the diagnosis of patent foramen ovale
    • Trevelyan J, Steeds RP. Comparison oftransthoracic echocardiographywith har-monic imaging with transoesophageal echocardiography for the diagnosis of patent foramen ovale. Postgrad Med J 2006;82:613-4.
    • (2006) Postgrad Med J , vol.82 , pp. 613-4
    • Trevelyan, J.1    Steeds, R.P.2
  • 14
    • 0028434405 scopus 로고
    • Accuracy of color Doppler transesophageal echocardio-graphy for diagnosis of patent foramen ovale
    • Berkompas DC, Sagar KB. Accuracy of color Doppler transesophageal echocardio-graphy for diagnosis of patent foramen ovale. J Am Soc Echocardiogr 1994;7(3 Pt 1): 253-6.
    • (1994) J Am Soc Echocardiogr , vol.7 , Issue.3 PART 1 , pp. 253-6
    • Berkompas, D.C.1    Sagar, K.B.2
  • 16
    • 0037005838 scopus 로고    scopus 로고
    • The usefulness of a 10% air-10% blood-80% saline mixture for contrast echocardiography: Doppler measurement of pulmonary artery systolic pressure
    • Jeon DS, Luo H, Iwami T, Miyamoto T, Brasch AV, Mirocha J et al. The usefulness of a 10% air-10% blood-80% saline mixture for contrast echocardiography: Doppler measurement of pulmonary artery systolic pressure. J Am Coll Cardiol 2002;39:124-9.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 124-9
    • Jeon, D.S.1    Luo, H.2    Iwami, T.3    Miyamoto, T.4    Brasch, A.V.5    Mirocha, J.6
  • 17
    • 31944446347 scopus 로고    scopus 로고
    • A critical review of patent foramen ovale detection using saline contrast echocardiography: When bubbles lie
    • Woods TD, Patel A. A critical review of patent foramen ovale detection using saline contrast echocardiography: when bubbles lie. J Am Soc Echocardiogr 2006; 19:215-22.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 215-22
    • Woods, T.D.1    Patel, A.2
  • 19
    • 12344334886 scopus 로고    scopus 로고
    • Traditional contrast echocardiogra-phy may fail to demonstrate a
    • patent foramen ovale: negative contrast in the right atrium may be a clue
    • Lindeboom JE, van Deudekom MJ, Visser CA. Traditional contrast echocardiogra-phy may fail to demonstrate a patent foramen ovale: negative contrast in the right atrium may be a clue. Eur J Echocardiogr 2005;6:75-78.
    • (2005) Eur J Echocardiogr , vol.6 , pp. 75-78
    • Lindeboom, J.E.1    Van Deudekom, M.J.2    Visser, C.A.3
  • 20
    • 33846197371 scopus 로고    scopus 로고
    • Brain abscess associated with an unusual cause of right to left shunt
    • Hirth A, Disney P, Thorne S. Brain abscess associated with an unusual cause of right to left shunt. Heart 2007;93:34.
    • (2007) Heart , vol.93 , pp. 34
    • Hirth, A.1    Disney, P.2    Thorne, S.3
  • 21
    • 0021244578 scopus 로고
    • Prevalence of right-to-left atrial shunting in a healthy population: Detection by Valsalva maneuver contrast echo-cardiography
    • Lynch JJ, Schuchard GH, Gross CM, Wann LS. Prevalence of right-to-left atrial shunting in a healthy population: detection by Valsalva maneuver contrast echo-cardiography. Am J Cardiol 1984;53:1478-80.
    • (1984) Am J Cardiol , vol.53 , pp. 1478-80
    • Lynch, J.J.1    Schuchard, G.H.2    Gross, C.M.3    Wann, L.S.4
  • 22
    • 43049083996 scopus 로고    scopus 로고
    • Sensitivity for detection of patent foramen ovale increased with increasing number of contrast injections: A descriptive study with contrast transesophageal echocardiography
    • Johansson MC, Helgason H, Dellborg M, Eriksson P. Sensitivity for detection of patent foramen ovale increased with increasing number of contrast injections: a descriptive study with contrast transesophageal echocardiography. J Am Soc Echo-cardiogr 2008;21:419-24.
    • (2008) J Am Soc Echo-cardiogr , vol.21 , pp. 419-24
    • Johansson, M.C.1    Helgason, H.2    Dellborg, M.3    Eriksson, P.4
  • 23
    • 0035400156 scopus 로고    scopus 로고
    • Bed tilt as an effort-independent maneuver to improve patent foramen ovale assessment by transthoracic contrast echocardiography
    • Kerr AJ, Chia KK, Buck T, Fry SJ, Myron PM, Rudski LG et al. Bed tilt as an effort-independent maneuver to improve patent foramen ovale assessment by transthoracic contrast echocardiography. Am J Cardiol 2001;88:A8, 94-98.
    • (2001) Am J Cardiol , vol.88 , Issue.A8 , pp. 94-98
    • Kerr, A.J.1    Chia, K.K.2    Buck, T.3    Fry, S.J.4    Myron, P.M.5    Rudski, L.G.6
  • 24
    • 0034668078 scopus 로고    scopus 로고
    • The association between the diameter of a patent foramen ovale and the risk of embolic cerebrovascular events
    • Schuchlenz HW, Weihs W, Horner S, Quehenberger F. The association between the diameter of a patent foramen ovale and the risk of embolic cerebrovascular events. Am J Med 2000;109:456-62.
    • (2000) Am J Med , vol.109 , pp. 456-62
    • Schuchlenz, H.W.1    Weihs, W.2    Horner, S.3    Quehenberger, F.4
  • 25
    • 0034669691 scopus 로고    scopus 로고
    • Transmitral Doppler: A new transthoracic contrast method for patent foramen ovale detection and quantification
    • Kerr AJ, Buck T, Chia K, Chow CM, Fox E, Levine RA et al. Transmitral Doppler: a new transthoracic contrast method for patent foramen ovale detection and quantification. J Am Coll Cardiol 2000;36:1959-66.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1959-66
    • Kerr, A.J.1    Buck, T.2    Chia, K.3    Chow, C.M.4    Fox, E.5    Levine, R.A.6
  • 26
    • 67650066715 scopus 로고    scopus 로고
    • Cerebral ischemic events associated with 'bubble study' for identification of right to left shunts
    • Romero JR, Frey JL, Schwamm LH, Demaerschalk BM, Chaliki HP, Parikh G et al. Cerebral ischemic events associated with 'bubble study' for identification of right to left shunts. Stroke 2009;40:2343-8.
    • (2009) Stroke , vol.40 , pp. 2343-8
    • Romero, J.R.1    Frey, J.L.2    Schwamm, L.H.3    Demaerschalk, B.M.4    Chaliki, H.P.5    Parikh, G.6
  • 27
    • 0021360847 scopus 로고
    • The safety of contrast echo-cardiography: Report of the Committee on Contrast Echocardiography for the American Society of Echocardiography
    • Bommer WJ, Shah PM, Allen H, Meltzer R, Kisslo J. The safety of contrast echo-cardiography: report of the Committee on Contrast Echocardiography for the American Society of Echocardiography. J Am Coll Cardiol 1984;3:6-13.
    • (1984) J Am Coll Cardiol , vol.3 , pp. 6-13
    • Bommer, W.J.1    Shah, P.M.2    Allen, H.3    Meltzer, R.4    Kisslo, J.5
  • 28
    • 77951095971 scopus 로고    scopus 로고
    • Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transe-sophageal two-dimensional contrast echocardiography for the detection of
    • patent foramen ovale
    • Monte I, Grasso S, Licciardi S, Badano LP. Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transe-sophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale. Eur J Echocardiogr 2010;11:245-9.
    • (2010) Eur J Echocardiogr , vol.11 , pp. 245-9
    • Monte, I.1    Grasso, S.2    Licciardi, S.3    Badano, L.P.4
  • 29
    • 64749113523 scopus 로고    scopus 로고
    • Real-time three-dimensional transoesophageal echo-cardiography for guidance of non-coronary interventions in the catheter labora-tory
    • Balzer J, Kelm M, Kuhl HP. Real-time three-dimensional transoesophageal echo-cardiography for guidance of non-coronary interventions in the catheter labora-tory. Eur J Echocardiogr 2009;10:341-9.
    • (2009) Eur J Echocardiogr , vol.10 , pp. 341-9
    • Balzer, J.1    Kelm, M.2    Kuhl, H.P.3
  • 31
    • 0037625759 scopus 로고    scopus 로고
    • Clinical use of Acu Nav diagnos-tic ultrasound catheter imaging during left heart radiofrequency ablation and transcatheter closure procedures
    • Ren JF, Marchlinski FE, Callans DJ, Herrmann HC. Clinical use of Acu Nav diagnos-tic ultrasound catheter imaging during left heart radiofrequency ablation and transcatheter closure procedures. J Am Soc Echocardiogr 2002;15(10 Pt 2): 1301-8.
    • (2002) J Am Soc Echocardiogr , vol.15 , Issue.10 PART 2 , pp. 1301-8
    • Ren, J.F.1    Marchlinski, F.E.2    Callans, D.J.3    Herrmann, H.C.4
  • 32
    • 77953820065 scopus 로고    scopus 로고
    • Use-fulness of trans-oesophageal echocardiography using intracardiac echography probe in guiding
    • patent foramen ovale percutaneous closure
    • Mitchell-Heggs L, Lim P, Bensaid A, Kloeckner M, Monin JL, Castanie JB et al. Use-fulness of trans-oesophageal echocardiography using intracardiac echography probe in guiding patent foramen ovale percutaneous closure. Eur J Echocardiogr 2010;11:394-400.
    • (2010) Eur J Echocardiogr , vol.11 , pp. 394-400
    • Mitchell-Heggs, L.1    Lim, P.2    Bensaid, A.3    Kloeckner, M.4    Monin, J.L.5    Castanie, J.B.6
  • 33
    • 59149104030 scopus 로고    scopus 로고
    • Late results after percutaneous closure of patent foramen ovale for secondary prevention of paradoxical embolism usingthe amplatzer PFO occluderwithout intraprocedural echocardiography: Effect of device size
    • Wahl A, Tai T, Praz F, Schwerzmann M, Seiler C, Nedeltchev K et al. Late results after percutaneous closure of patent foramen ovale for secondary prevention of paradoxical embolism usingthe amplatzer PFO occluderwithout intraprocedural echocardiography: effect of device size. JACC Cardiovasc Interv 2009;2:116-23.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 116-23
    • Wahl, A.1    Tai, T.2    Praz, F.3    Schwerzmann, M.4    Seiler, C.5    Nedeltchev, K.6
  • 34
    • 49449084107 scopus 로고    scopus 로고
    • Patent foramen ovale closure without echocardiographic control: Use of 'standby' intracardiac ultra-sound
    • Hildick-Smith D, Behan M, Haworth P, Rana B, Thomas M. Patent foramen ovale closure without echocardiographic control: use of 'standby' intracardiac ultra-sound. JACC Cardiovasc Interv 2008;1:387-91.
    • (2008) JACC Cardiovasc Interv , vol.1 , pp. 387-91
    • Hildick-Smith, D.1    Behan, M.2    Haworth, P.3    Rana, B.4    Thomas, M.5
  • 35
    • 54949115916 scopus 로고    scopus 로고
    • Spontaneous left atrial thrombus during patent foramen ovale closure
    • Hudsmith L, Thorne S, Clift P. Spontaneous left atrial thrombus during patent foramen ovale closure. Eur J Echocardiogr 2008;9:824.
    • (2008) Eur J Echocardiogr , vol.9 , pp. 824
    • Hudsmith, L.1    Thorne, S.2    Clift, P.3
  • 36
    • 1642389024 scopus 로고    scopus 로고
    • Transcath-eter closure of patent foramen ovale (PFO) in patients with paradoxical embo-lism Periprocedural safety and mid-term follow-up results of three different device occluder systems
    • Braun M, Gliech V, Boscheri A, Schoen S, Gahn G, Reichmann H et al. Transcath-eter closure of patent foramen ovale (PFO) in patients with paradoxical embo-lism. Periprocedural safety and mid-term follow-up results of three different device occluder systems. Eur Heart J 2004;25:424-30.
    • (2004) Eur Heart J , vol.25 , pp. 424-30
    • Braun, M.1    Gliech, V.2    Boscheri, A.3    Schoen, S.4    Gahn, G.5    Reichmann, H.6
  • 38
    • 0032387854 scopus 로고    scopus 로고
    • Trans-catheter closure of atrial septal defect and patent foramen ovale with ASDOS device (a multi-institutional European trial)
    • Sievert H, Babic UU, Hausdorf G, Schneider M, Hopp HW, Pfeiffer D et al. Trans-catheter closure of atrial septal defect and patent foramen ovale with ASDOS device (a multi-institutional European trial). Am J Cardiol 1998;82:1405-13.
    • (1998) Am J Cardiol , vol.82 , pp. 1405-13
    • Sievert, H.1    Babic, U.U.2    Hausdorf, G.3    Schneider, M.4    Hopp, H.W.5    Pfeiffer, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.