1
-
-
6344279826
-
Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms
-
J. Huang, R.G. Holt, R.O. Cleveland, and R.A. Roy Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms J. Acoust. Soc. Am. 116 2004 2451 2458
-
(2004)
J. Acoust. Soc. Am.
, vol.116
, pp. 2451-2458
-
-
Huang, J.1
Holt, R.G.2
Cleveland, R.O.3
Roy, R.A.4
-
2
-
-
51849129996
-
Investigation of the viscous heating artifact arising from the use of thermocouples in a focused ultrasound field
-
H. Morris, I. Rivens, A. Shaw, and G. Ter Haar Investigation of the viscous heating artifact arising from the use of thermocouples in a focused ultrasound field Phys. Med. Biol. 53 2008 4759
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 4759
-
-
Morris, H.1
Rivens, I.2
Shaw, A.3
Ter Haar, G.4
-
3
-
-
0021911812
-
Thermal conduction errors in manganine-constantan thermocouple
-
R.J. Dickinson Thermal conduction errors in manganine-constantan thermocouple Phys. Med. Biol. 30 1985 445 453
-
(1985)
Phys. Med. Biol.
, vol.30
, pp. 445-453
-
-
Dickinson, R.J.1
-
4
-
-
30244463882
-
Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes - Theory
-
W.J. Fry, and R.B. Fry Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes - theory J. Acoust. Soc. Am. 26 1954 294 310
-
(1954)
J. Acoust. Soc. Am.
, vol.26
, pp. 294-310
-
-
Fry, W.J.1
Fry, R.B.2
-
5
-
-
0021077960
-
Ultrasonic attenuation and absorption in liver tissue
-
K.J. Parker Ultrasonic attenuation and absorption in liver tissue Ultrasound Med. Biol. 9 1983 363 369
-
(1983)
Ultrasound Med. Biol.
, vol.9
, pp. 363-369
-
-
Parker, K.J.1
-
6
-
-
60249089204
-
Pulsed high intensity focused ultrasound mediated nanoparticle delivery: Mechanisms and efficacy in murine muscle
-
B. O'Neill, H. Vo, M. Angstadt, K.P.C. Li, T. Quinn, and V. Frenkel Pulsed high intensity focused ultrasound mediated nanoparticle delivery: mechanisms and efficacy in murine muscle Ultrasound Med. Biol. 35 2009 416 424
-
(2009)
Ultrasound Med. Biol.
, vol.35
, pp. 416-424
-
-
O'Neill, B.1
Vo, H.2
Angstadt, M.3
Li, K.P.C.4
Quinn, T.5
Frenkel, V.6
-
7
-
-
84888360034
-
Analysis of tissue and arterial temperatures in the resting human Forearm
-
H.H. Pennes Analysis of tissue and arterial temperatures in the resting human Forearm J. Appl. Physiol. 1 1948 92 122
-
(1948)
J. Appl. Physiol.
, vol.1
, pp. 92-122
-
-
Pennes, H.H.1
-
8
-
-
0016125222
-
The energy conservation equation for liver tissue
-
W. Wulff The energy conservation equation for liver tissue IEEE Trans. Biomed. Eng. 21 1974 494 495
-
(1974)
IEEE Trans. Biomed. Eng.
, vol.21
, pp. 494-495
-
-
Wulff, W.1
-
9
-
-
0031213562
-
A new fundamental bioheat equation for muscle tissue: Part i - Blood perfusion term
-
S. Weinbaum, L.X. Xu, L. Zhu, and A. Ekpene A new fundamental bioheat equation for muscle tissue: part I - blood perfusion term ASME J. Biomech. Eng. 119 1997 278 288
-
(1997)
ASME J. Biomech. Eng.
, vol.119
, pp. 278-288
-
-
Weinbaum, S.1
Xu, L.X.2
Zhu, L.3
Ekpene, A.4
-
10
-
-
0032103920
-
A generic tissue convective energy balance equation: Part i - Theory and derivation
-
R.B. Roemer, and A.W. Dutton A generic tissue convective energy balance equation: part I - theory and derivation ASME J. Biomech. Eng. 120 1998 395 404
-
(1998)
ASME J. Biomech. Eng.
, vol.120
, pp. 395-404
-
-
Roemer, R.B.1
Dutton, A.W.2
-
11
-
-
0029957881
-
Blood flow cooling and ultrasonic lesion formation
-
M.C. Kolios, M.D. Sherar, and J.W. Hunt Blood flow cooling and ultrasonic lesion formation Med. Phys. 23 1996 1287 1298
-
(1996)
Med. Phys.
, vol.23
, pp. 1287-1298
-
-
Kolios, M.C.1
Sherar, M.D.2
Hunt, J.W.3
-
14
-
-
0031897969
-
Comparison of temperature distributions in interstitial hyperthermia: Experiments in bovine tongues versus generic simulations
-
B.W. Raaymakers, J. Crezee, and J.J.W. Lagendijk Comparison of temperature distributions in interstitial hyperthermia: experiments in bovine tongues versus generic simulations Phys. Med. Biol. 43 1998 1199 1214
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 1199-1214
-
-
Raaymakers, B.W.1
Crezee, J.2
Lagendijk, J.J.W.3
-
15
-
-
0037080266
-
Percutaneous RF tumor ablation
-
B.J. Wood, J.R. Ramkaransingh, T. Fojo, M.M. Walther, and S.K. Libutti Percutaneous RF tumor ablation Cancer 15 2002 443 451
-
(2002)
Cancer
, vol.15
, pp. 443-451
-
-
Wood, B.J.1
Ramkaransingh, J.R.2
Fojo, T.3
Walther, M.M.4
Libutti, S.K.5
-
16
-
-
0035183913
-
RF Liver Ablation: Experimental Comparative Study of Water-Cooled Versus Expandable Systems
-
T.D. Baere, A. Denys, B.J. Wood, N. Lassau, M. Kardache, V. Vilgrain, Y. Menu, A. Roche, RF Liver Ablation: Experimental Comparative Study of Water-Cooled Versus Expandable Systems, AJR, vol. 176, 2001, pp. 187-192.
-
(2001)
AJR
, vol.176
, pp. 187-192
-
-
Baere, T.D.1
Denys, A.2
Wood, B.J.3
Lassau, N.4
Kardache, M.5
Vilgrain, V.6
Menu, Y.7
Roche, A.8
-
17
-
-
0030210698
-
RF tissue ablation: Increased lesion diameter with a perfusion electrode
-
S.N. Goldberg, G.S. Gazelle, L. Solbiati, W.J. Rittman, and P.R. Mueller RF tissue ablation: increased lesion diameter with a perfusion electrode Acad. Radiol. 3 1996 636 644
-
(1996)
Acad. Radiol.
, vol.3
, pp. 636-644
-
-
Goldberg, S.N.1
Gazelle, G.S.2
Solbiati, L.3
Rittman, W.J.4
Mueller, P.R.5
-
18
-
-
0027984211
-
Dose uniformity in scanned focused ultrasound hyperthermia
-
J.J.W. Lagendijk, J. Crezee, and J.W. Hand Dose uniformity in scanned focused ultrasound hyperthermia Int. J. Hyperther. 10 1994 775 784
-
(1994)
Int. J. Hyperther.
, vol.10
, pp. 775-784
-
-
Lagendijk, J.J.W.1
Crezee, J.2
Hand, J.W.3
-
19
-
-
0036195651
-
A blood vessel exposed to ultrasound: A mathematical simulation of the temperature field
-
B. Krasovitski, and E. Kimmel A blood vessel exposed to ultrasound: a mathematical simulation of the temperature field J. Acoust. Soc. Am. 111 2002 1454 1459
-
(2002)
J. Acoust. Soc. Am.
, vol.111
, pp. 1454-1459
-
-
Krasovitski, B.1
Kimmel, E.2
-
20
-
-
0034226983
-
Numerical simulation of heating patterns and tissue temperature response due to high-intensity focused ultrasound
-
F.P. Curra, P.D. Mourad, V.A. Khokhlova, R.O. Cleveland, and L.A. Crum Numerical simulation of heating patterns and tissue temperature response due to high-intensity focused ultrasound IEEE Trans. Ultrasound Ferroelect. Freq. Control 47 2000 1077 1089
-
(2000)
IEEE Trans. Ultrasound Ferroelect. Freq. Control
, vol.47
, pp. 1077-1089
-
-
Curra, F.P.1
Mourad, P.D.2
Khokhlova, V.A.3
Cleveland, R.O.4
Crum, L.A.5
-
21
-
-
33846899004
-
Effects of large blood vessel locations during high intensity focused ultrasound therapy for hepatic tumors: A finite element study, Engineering in Medicine and Biology Society
-
C.X. Zhang, S. Zhang, Y.Z. Chen, Effects of large blood vessel locations during high intensity focused ultrasound therapy for hepatic tumors: a finite element study, Engineering in Medicine and Biology Society, 2005, in: IEEE-EMBS 2005. 27th Annual International Conference of the 2005, pp. 209-212.
-
(2005)
IEEE-EMBS 2005. 27th Annual International Conference of the 2005
, pp. 209-212
-
-
Zhang, C.X.1
Zhang, S.2
Chen, Y.Z.3
-
22
-
-
34249657878
-
HIFU procedures at moderate intensities - Effect of large blood vessels
-
P. Hariharan, M.R. Myers, and R.K. Banerjee HIFU procedures at moderate intensities - effect of large blood vessels Phys. Med. Biol. 52 2007 3493 3535
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 3493-3535
-
-
Hariharan, P.1
Myers, M.R.2
Banerjee, R.K.3
-
23
-
-
34250218002
-
Development of a HIFU phantom
-
Oxford, UK, 31 August-02 September
-
R.L. King, B.A. Herman, S. Maruvada, K.A. Wear, G.R. Harris, Development of a HIFU phantom, in: Proc. 6th Int. Symp. on Therapeutic Ultrasound, Oxford, UK, 31 August-02 September 2006.
-
(2006)
Proc. 6th Int. Symp. on Therapeutic Ultrasound
-
-
King, R.L.1
Herman, B.A.2
Maruvada, S.3
Wear, K.A.4
Harris, G.R.5
-
24
-
-
1642632806
-
Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 MHz to 2 MHz via time delay spectrometry
-
G.R. Harris, P.M. Gammell, P.A. Lewin, and E. Radulescu Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 MHz to 2 MHz via time delay spectrometry Ultrasonics 42 2004 349 353
-
(2004)
Ultrasonics
, vol.42
, pp. 349-353
-
-
Harris, G.R.1
Gammell, P.M.2
Lewin, P.A.3
Radulescu, E.4
-
25
-
-
0026687402
-
Temperature uniformity during hyperthermia: The impact of large vessels
-
J. Creezee, and J.J.W. Lagendijk Temperature uniformity during hyperthermia: the impact of large vessels Phys. Med. Biol. 37 1992 1321 1337
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1321-1337
-
-
Creezee, J.1
Lagendijk, J.J.W.2
-
26
-
-
34147182208
-
Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique
-
S. Maruvada, G.R. Harris, B.A. Herman, and R.L. King Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique J. Acoust. Soc. Am. 121 2007 1434 1439
-
(2007)
J. Acoust. Soc. Am.
, vol.121
, pp. 1434-1439
-
-
Maruvada, S.1
Harris, G.R.2
Herman, B.A.3
King, R.L.4
-
27
-
-
40749128357
-
Characterization of high intensity focused ultrasound transducers using acoustic streaming
-
P. Hariharan, M.R. Myers, R.A. Robinson, S. Maruvada, J. Sliva, and R.K. Banerjee Characterization of high intensity focused ultrasound transducers using acoustic streaming J. Acoust. Soc. Am. 123 2008 1706 1719
-
(2008)
J. Acoust. Soc. Am.
, vol.123
, pp. 1706-1719
-
-
Hariharan, P.1
Myers, M.R.2
Robinson, R.A.3
Maruvada, S.4
Sliva, J.5
Banerjee, R.K.6
-
28
-
-
0000238336
-
A simplex method for function minimization
-
J.A. Nelder, and R. Mead A simplex method for function minimization Comput. J. 7 1965 308 313
-
(1965)
Comput. J.
, vol.7
, pp. 308-313
-
-
Nelder, J.A.1
Mead, R.2
-
29
-
-
0016473731
-
The Nelder mead simplex procedure for function minimization
-
D.M. Olsson, and L.S. Nelson The Nelder mead simplex procedure for function minimization Technometrics 17 1975 45 51
-
(1975)
Technometrics
, vol.17
, pp. 45-51
-
-
Olsson, D.M.1
Nelson, L.S.2
-
31
-
-
78649332075
-
-
Fluent Inc. 2002b, FIDAP User Manual ver. 8.6.2.
-
Fluent Inc. 2002b, FIDAP User Manual ver. 8.6.2.
-
-
-
|