메뉴 건너뛰기




Volumn 10, Issue 12, 2010, Pages 1065-1068

Dural repair with four spinal sealants: Focused review of the manufacturers' inserts and the current literature

Author keywords

Cerebrospinal fluid fistulas; Dural closure techniques; Durotomy; Fibrin glue; Sealants

Indexed keywords

FIBRIN GLUE; SEALANT;

EID: 78649303259     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2010.09.017     Document Type: Article
Times cited : (76)

References (14)
  • 2
    • 43049120606 scopus 로고    scopus 로고
    • Cerebrospinal fluid leaks following cervical spine surgery
    • D. Hannallah, J. Lee, and M. Khan Cerebrospinal fluid leaks following cervical spine surgery J Bone Joint Surg Am 90 2008 1101 1105
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1101-1105
    • Hannallah, D.1    Lee, J.2    Khan, M.3
  • 3
    • 75649112307 scopus 로고    scopus 로고
    • Wound-peritoneal shunts: Part of the complex management of anterior dural lacerations in patients with ossification of the posterior longitudinal ligament
    • N.E. Epstein Wound-peritoneal shunts: part of the complex management of anterior dural lacerations in patients with ossification of the posterior longitudinal ligament Surg Neurol 72 2009 630 634
    • (2009) Surg Neurol , vol.72 , pp. 630-634
    • Epstein, N.E.1
  • 4
    • 56849102250 scopus 로고    scopus 로고
    • Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery
    • K.D. Than, C.J. Baird, and A. Olivi Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery Neurosurgery 63 1 Suppl 1 2008 ONS182 ONS186
    • (2008) Neurosurgery , vol.63 , Issue.1 SUPPL. 1
    • Than, K.D.1    Baird, C.J.2    Olivi, A.3
  • 5
    • 76149120841 scopus 로고    scopus 로고
    • Postoperative cervical cord compression induced by hydyrogel (DuraSeal): A possible complication
    • D. Thavarajah, P. De Lacy, R. Hussain, and R.M. Redfern Postoperative cervical cord compression induced by hydyrogel (DuraSeal): a possible complication Spine 35 2010 E25 E26
    • (2010) Spine , vol.35
    • Thavarajah, D.1    De Lacy, P.2    Hussain, R.3    Redfern, R.M.4
  • 6
    • 67651083430 scopus 로고    scopus 로고
    • Complications associated with single-level transforaminal lumbar interbody fusion
    • J.A. Rihn, R. Patel, and J. Makda Complications associated with single-level transforaminal lumbar interbody fusion Spine J 9 2009 623 629
    • (2009) Spine J , vol.9 , pp. 623-629
    • Rihn, J.A.1    Patel, R.2    Makda, J.3
  • 7
    • 64749110882 scopus 로고    scopus 로고
    • Cauda equina compression by hydrogel dural sealant after a laminotomy and discectomy: Case report
    • M. Mulder, J. Crosier, and R. Dunn Cauda equina compression by hydrogel dural sealant after a laminotomy and discectomy: case report Spine 34 2009 E144 E148
    • (2009) Spine , vol.34
    • Mulder, M.1    Crosier, J.2    Dunn, R.3
  • 8
    • 0242558053 scopus 로고    scopus 로고
    • Evaluation of the use of BioGlue in neurosurgical procedures
    • A. Kumar, N.F. Maartens, and A.H. Kaye Evaluation of the use of BioGlue in neurosurgical procedures J Clin Neurosci 10 2003 661 664
    • (2003) J Clin Neurosci , vol.10 , pp. 661-664
    • Kumar, A.1    Maartens, N.F.2    Kaye, A.H.3
  • 9
    • 0037212502 scopus 로고    scopus 로고
    • Reconstruction of the sellar floor using Bioglue following transsphenoidal procedures
    • A. Kumar, N.F. Maartens, and A.H. Kaye Reconstruction of the sellar floor using Bioglue following transsphenoidal procedures J Clin Neurosci 10 2003 92 95
    • (2003) J Clin Neurosci , vol.10 , pp. 92-95
    • Kumar, A.1    Maartens, N.F.2    Kaye, A.H.3
  • 10
    • 11444254256 scopus 로고    scopus 로고
    • Persistence of Bioglue in spinal dural repair
    • T. Yuen, and A.H. Kaye Persistence of Bioglue in spinal dural repair J Clin Neurosci 12 2005 100 101
    • (2005) J Clin Neurosci , vol.12 , pp. 100-101
    • Yuen, T.1    Kaye, A.H.2
  • 11
    • 54449095594 scopus 로고    scopus 로고
    • Application of EVICEL to cavernous nerves of the rat does not influence erective function in vivo
    • T.J. Bivalacqua, T.J. Guzzo, and E.M. Schaeffer Application of EVICEL to cavernous nerves of the rat does not influence erective function in vivo Urology 72 2008 1169 1173
    • (2008) Urology , vol.72 , pp. 1169-1173
    • Bivalacqua, T.J.1    Guzzo, T.J.2    Schaeffer, E.M.3
  • 12
    • 34548700185 scopus 로고    scopus 로고
    • The use of fibrin glue to stop venous bleeding in the epidural space, vertebral venous plexus, and anterior cavernous sinus: Technical note
    • L.N. Sekhar, S.K. Natarajan, T. Manning, and D. Bhagawati The use of fibrin glue to stop venous bleeding in the epidural space, vertebral venous plexus, and anterior cavernous sinus: technical note Neurosurgery 61 3 Suppl 2007 E51
    • (2007) Neurosurgery , vol.61 , Issue.3 SUPPL. , pp. 51
    • Sekhar, L.N.1    Natarajan, S.K.2    Manning, T.3    Bhagawati, D.4
  • 13
    • 58149122902 scopus 로고    scopus 로고
    • Effect of fibrin sealant on drain output and duration of hospitalization after multilevel anterior cervical fusion: A retrospective matched pair analysis
    • J.S. Yeom, J.M. Buchowski, and H.X. Shen Effect of fibrin sealant on drain output and duration of hospitalization after multilevel anterior cervical fusion: a retrospective matched pair analysis Spine 33 2008 E543 E547
    • (2008) Spine , vol.33
    • Yeom, J.S.1    Buchowski, J.M.2    Shen, H.X.3
  • 14
    • 69549103393 scopus 로고    scopus 로고
    • Effect of fibrin glue on the prevention of persistent cerebral spinal fluid leakage after incidental durotomy during lumbar spinal surgery
    • B.T. Jankowitz, D.S. Atteberry, and P.C. Gerszten Effect of fibrin glue on the prevention of persistent cerebral spinal fluid leakage after incidental durotomy during lumbar spinal surgery Eur Spine J 18 2009 1169 1172
    • (2009) Eur Spine J , vol.18 , pp. 1169-1172
    • Jankowitz, B.T.1    Atteberry, D.S.2    Gerszten, P.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.