메뉴 건너뛰기




Volumn 31, Issue 6, 2010, Pages 1032-1039

Combining magnetic resonance measurements with numerical simulations - Extracting blood flow physiology information relevant to the investigation of intracranial aneurysms in the circle of Willis

Author keywords

Cerebral aneurysms; Computational fluid dynamics (CFD); Hemodynamics; Oscillatory shear index (OSI); Phase contrast magnetic resonance angiography (PC MRA); Wall shear stress gradient (WSSG)

Indexed keywords

CEREBRAL ANEURYSMS; COMPUTATIONAL FLUID; OSCILLATORY SHEAR INDEX; PHASE-CONTRAST MAGNETIC RESONANCES; WALL SHEAR STRESS GRADIENTS;

EID: 78449283872     PISSN: 0142727X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijheatfluidflow.2010.07.003     Document Type: Article
Times cited : (14)

References (27)
  • 1
    • 33748329507 scopus 로고    scopus 로고
    • Estimating the hemodynamic impact of interventional treatments of aneurysms: numerical simulation with experimental validation: technical case report
    • (author reply E429-430)
    • Acevedo-Bolton G., Jou L.D., Dispensa B.P., Lawton M.T., Higashida R.T., Martin A.J., Young W.L., Saloner D. Estimating the hemodynamic impact of interventional treatments of aneurysms: numerical simulation with experimental validation: technical case report. Neurosurgery 2006, 59:E429-430. (author reply E429-430).
    • (2006) Neurosurgery , vol.59
    • Acevedo-Bolton, G.1    Jou, L.D.2    Dispensa, B.P.3    Lawton, M.T.4    Higashida, R.T.5    Martin, A.J.6    Young, W.L.7    Saloner, D.8
  • 2
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • Bryant D.J., Payne J.A., Firmin D.N., Longmore D.B. Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. J. Comput. Assist. Tomogr. 1984, 8:588-593.
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , pp. 588-593
    • Bryant, D.J.1    Payne, J.A.2    Firmin, D.N.3    Longmore, D.B.4
  • 3
    • 0942269388 scopus 로고    scopus 로고
    • Blood-flow models of the circle of Willis from magnetic resonance data
    • Cebral J.R., Castro M.A., Soto O., Löhner R., Alperin N. Blood-flow models of the circle of Willis from magnetic resonance data. J. Eng. Math. 2003, 47:369-386.
    • (2003) J. Eng. Math. , vol.47 , pp. 369-386
    • Cebral, J.R.1    Castro, M.A.2    Soto, O.3    Löhner, R.4    Alperin, N.5
  • 4
    • 33845682167 scopus 로고    scopus 로고
    • Haemodynamics and wall remodelling of a growing cerebral aneurysm: a computational model
    • Chatziprodromou I., Tricoli A., Poulikakos D., Ventikos Y. Haemodynamics and wall remodelling of a growing cerebral aneurysm: a computational model. J. Biomech. 2007, 40:412-426.
    • (2007) J. Biomech. , vol.40 , pp. 412-426
    • Chatziprodromou, I.1    Tricoli, A.2    Poulikakos, D.3    Ventikos, Y.4
  • 5
    • 33644787946 scopus 로고    scopus 로고
    • Natural history and general management of unruptured intracranial aneurysms
    • Chen P.R., Frerichs K., Spetzler R. Natural history and general management of unruptured intracranial aneurysms. Neurosurg. Focus 2004, 17:E1.
    • (2004) Neurosurg. Focus , vol.17
    • Chen, P.R.1    Frerichs, K.2    Spetzler, R.3
  • 8
    • 0029081103 scopus 로고
    • Measurement of fluid-shear rate by Fourier-encoded velocity imaging
    • Frayne R., Rutt B.K. Measurement of fluid-shear rate by Fourier-encoded velocity imaging. Magn. Reson. Med. 1995, 34:378-387.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 378-387
    • Frayne, R.1    Rutt, B.K.2
  • 9
    • 0030087598 scopus 로고    scopus 로고
    • Pulsatile flow in the human left coronary artery bifurcation: average conditions
    • He X., Ku D.N. Pulsatile flow in the human left coronary artery bifurcation: average conditions. J. Biomech. Eng. 1996, 118:74-82.
    • (1996) J. Biomech. Eng. , vol.118 , pp. 74-82
    • He, X.1    Ku, D.N.2
  • 10
    • 37349108181 scopus 로고    scopus 로고
    • Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: validation in an anatomically accurate cerebral artery aneurysm model with steady flow
    • Hollnagel D.I., Summers P.E., Kollias S.S., Poulikakos D. Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: validation in an anatomically accurate cerebral artery aneurysm model with steady flow. J. Magn. Reson. Imag. 2007, 26:1493-1505.
    • (2007) J. Magn. Reson. Imag. , vol.26 , pp. 1493-1505
    • Hollnagel, D.I.1    Summers, P.E.2    Kollias, S.S.3    Poulikakos, D.4
  • 11
    • 70649093030 scopus 로고    scopus 로고
    • Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics
    • Hollnagel D.I., Summers P.E., Poulikakos D., Kollias S.S. Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics. NMR Biomed. 2009, 22:795-808.
    • (2009) NMR Biomed. , vol.22 , pp. 795-808
    • Hollnagel, D.I.1    Summers, P.E.2    Poulikakos, D.3    Kollias, S.S.4
  • 12
    • 36148991420 scopus 로고    scopus 로고
    • Flow patterns in three-dimensional porcine epicardial coronary arterial tree
    • Huo Y., Wischgoll T., Kassab G.S. Flow patterns in three-dimensional porcine epicardial coronary arterial tree. Am. J. Physiol. Heart Circ. Physiol. 2007, 293:H2959-H2970.
    • (2007) Am. J. Physiol. Heart Circ. Physiol. , vol.293
    • Huo, Y.1    Wischgoll, T.2    Kassab, G.S.3
  • 14
    • 0030812659 scopus 로고    scopus 로고
    • Epidemiology of aneurysmal subarachnoid hemorrhage
    • King J.T. Epidemiology of aneurysmal subarachnoid hemorrhage. Neuroimag. Clin. North Am. 1997, 7:659-668.
    • (1997) Neuroimag. Clin. North Am. , vol.7 , pp. 659-668
    • King, J.T.1
  • 15
    • 44649088998 scopus 로고    scopus 로고
    • In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T
    • Meckel S., Stalder A.F., Santini F., Radu E.W., Rufenacht D.A., Markl M., Wetzel S.G. In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T. Neuroradiology 2008, 50:473-484.
    • (2008) Neuroradiology , vol.50 , pp. 473-484
    • Meckel, S.1    Stalder, A.F.2    Santini, F.3    Radu, E.W.4    Rufenacht, D.A.5    Markl, M.6    Wetzel, S.G.7
  • 16
    • 47149101252 scopus 로고    scopus 로고
    • Numerical simulation of pre- and postsurgical flow in a giant basilar aneurysm
    • Rayz V.L., Lawton M.T., Martin A.J., Young W.L., Saloner D. Numerical simulation of pre- and postsurgical flow in a giant basilar aneurysm. J. Biomech. Eng. 2008, 130:021004.
    • (2008) J. Biomech. Eng. , vol.130 , pp. 021004
    • Rayz, V.L.1    Lawton, M.T.2    Martin, A.J.3    Young, W.L.4    Saloner, D.5
  • 19
    • 0031984850 scopus 로고    scopus 로고
    • Prevalence and risk of rupture of intracranial aneurysms: a systematic review
    • Rinkel G.J., Djibuti M., Algra A., van Gijn J. Prevalence and risk of rupture of intracranial aneurysms: a systematic review. Stroke 1998, 29:251-256.
    • (1998) Stroke , vol.29 , pp. 251-256
    • Rinkel, G.J.1    Djibuti, M.2    Algra, A.3    van Gijn, J.4
  • 21
    • 33644798941 scopus 로고    scopus 로고
    • Contemporary management of incidental intracranial aneurysms
    • Tummala R.P., Baskaya M.K., Heros R.C. Contemporary management of incidental intracranial aneurysms. Neurosurg. Focus 2005, 18:e9.
    • (2005) Neurosurg. Focus , vol.18
    • Tummala, R.P.1    Baskaya, M.K.2    Heros, R.C.3
  • 22
    • 0028545624 scopus 로고
    • MR measurements of pulsatile pressure gradients
    • Urchuk S.N., Plewes D.B. MR measurements of pulsatile pressure gradients. J. Magn. Reson. Imag. 1994, 4:829-836.
    • (1994) J. Magn. Reson. Imag. , vol.4 , pp. 829-836
    • Urchuk, S.N.1    Plewes, D.B.2
  • 23
  • 24
    • 0036125665 scopus 로고    scopus 로고
    • Unruptured intracranial aneurysms: a review
    • Weir B. Unruptured intracranial aneurysms: a review. J. Neurosurg. 2002, 96:3-42.
    • (2002) J. Neurosurg. , vol.96 , pp. 3-42
    • Weir, B.1
  • 26
    • 0036125722 scopus 로고    scopus 로고
    • Prevalence of asymptomatic incidental aneurysms: review of 4568 arteriograms
    • Winn H.R., Jane J.A., Taylor J., Kaiser D., Britz G.W. Prevalence of asymptomatic incidental aneurysms: review of 4568 arteriograms. J. Neurosurg. 2002, 96:43-49.
    • (2002) J. Neurosurg. , vol.96 , pp. 43-49
    • Winn, H.R.1    Jane, J.A.2    Taylor, J.3    Kaiser, D.4    Britz, G.W.5
  • 27
    • 0041375626 scopus 로고    scopus 로고
    • Comparative study of magnetic resonance imaging and image-based computational fluid dynamics for quantification of pulsatile flow in a carotid bifurcation phantom
    • Zhao S.Z., Papathanasopoulou P., Long Q., Marshall I., Xu X.Y. Comparative study of magnetic resonance imaging and image-based computational fluid dynamics for quantification of pulsatile flow in a carotid bifurcation phantom. Ann. Biomed. Eng. 2003, 31:962-971.
    • (2003) Ann. Biomed. Eng. , vol.31 , pp. 962-971
    • Zhao, S.Z.1    Papathanasopoulou, P.2    Long, Q.3    Marshall, I.4    Xu, X.Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.