메뉴 건너뛰기




Volumn 21, Issue 10, 2010, Pages 2843-2851

In vivo biocompatibility assessment of (PTFE-PVDF-PP) terpolymer-based membrane with potential application for glaucoma treatment

Author keywords

[No Author keywords available]

Indexed keywords

BASE MATERIAL; BIOCOMPABILITY; CLINICAL OBSERVATION; CLINICAL SYMPTOMS; DEEP SCLERECTOMY; EXPERIMENTAL GROUPS; GLAUCOMA IMPLANT; IN-VIVO; ISO 10993; PHYSICAL TREATMENTS; PORE SYSTEM; POTENTIAL APPLICATIONS; RABBIT MODELS; SYNTHETIC TERPOLYMER;

EID: 78349310931     PISSN: 09574530     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10856-010-4132-3     Document Type: Article
Times cited : (21)

References (26)
  • 1
    • 44949165680 scopus 로고    scopus 로고
    • Non-penetrating filtration surgery versus trabeculectomy for open angle glaucoma
    • DOI 10.1002/14651858.CD007059
    • Eldaly M, Anand N, Bunce C,Khafagy M. Non-penetrating filtration surgery versus trabeculectomy for open angle glaucoma. (Protocol) Cochrane Database Syst Rev. 2008; Issue 2. CD007059. DOI: 10.1002/14651858.CD007059. (Pubitemid 351807380)
    • (2008) Cochrane Database of Systematic Reviews , Issue.2
    • Eldaly, M.1    Anand, N.2    Bunce, C.3    Khafagy, M.4
  • 2
    • 85044710349 scopus 로고    scopus 로고
    • The clinical effectiveness and cost-effectiveness of screening for open angle glaucoma: A systematic review and economic evaluation
    • JM Burr G Mowatt R Hernández MAR Siddiqui J Cook T Lourenco, et al. 2007 The clinical effectiveness and cost-effectiveness of screening for open angle glaucoma: a systematic review and economic evaluation Health Technol Assess 11 41 1 206
    • (2007) Health Technol Assess , vol.11 , Issue.41 , pp. 1-206
    • Burr, J.M.1    Mowatt, G.2    Hernández, R.3    Siddiqui, M.A.R.4    Cook, J.5    Lourenco, T.6
  • 3
    • 1642463329 scopus 로고    scopus 로고
    • Glaucoma-2: Treatment
    • 1:STN:280:DC%2BD2c%2Fis1Ohtg%3D%3D 10.1136/bmj.328.7432.156 14726349
    • PT Khaw P Shah AR Elkington 2004 Glaucoma-2: treatment BMJ 328 7432 156 158 1:STN:280:DC%2BD2c%2Fis1Ohtg%3D%3D 10.1136/bmj.328.7432.156 14726349
    • (2004) BMJ , vol.328 , Issue.7432 , pp. 156-158
    • Khaw, P.T.1    Shah, P.2    Elkington, A.R.3
  • 4
    • 0034001998 scopus 로고    scopus 로고
    • Clinical management of glaucoma
    • 1:STN:280:DC%2BD3czgtlejsg%3D%3D 10844881
    • A King C Migdal 2000 Clinical management of glaucoma J R Soc Med 93 4 175 177 1:STN:280:DC%2BD3czgtlejsg%3D%3D 10844881
    • (2000) J R Soc Med , vol.93 , Issue.4 , pp. 175-177
    • King, A.1    Migdal, C.2
  • 6
    • 0027739651 scopus 로고
    • Current concepts in the diagnosis and management of developmental glaucomas
    • 1:STN:280:DyaK2c%2Fos1SktQ%3D%3D 8262604
    • AK Mandal 1993 Current concepts in the diagnosis and management of developmental glaucomas Indian J Ophthalmol 41 51 70 1:STN:280: DyaK2c%2Fos1SktQ%3D%3D 8262604
    • (1993) Indian J Ophthalmol , vol.41 , pp. 51-70
    • Mandal, A.K.1
  • 7
    • 33646934641 scopus 로고    scopus 로고
    • Glaucoma drainage implants: A critical comparison of types
    • DOI 10.1097/01.icu.0000193080.55240.7e, PII 0005573520060400000011
    • KS Schwartz RK Lee SJ Gedde 2006 Glaucoma drainage implants: a critical comparison of types Curr Opin Ophthalmol 17 2 181 189 10.1097/01.icu.0000193080. 55240.7e 16552254 (Pubitemid 43790815)
    • (2006) Current Opinion in Ophthalmology , vol.17 , Issue.2 , pp. 181-189
    • Schwartz, K.S.1    Lee, R.K.2    Gedde, S.J.3
  • 8
    • 23044513096 scopus 로고    scopus 로고
    • Glaucoma drainage implants in pediatric patients
    • DOI 10.1016/j.ohc.2005.05.009, PII S0896154905000519, Glaucoma
    • K Ishida AK Mandal PA Netland 2005 Glaucoma drainage implants in pediatric patients Ophthalmol Clin North Am 18 3 431 442 10.1016/j.ohc.2005.05. 009 16055000 (Pubitemid 41073868)
    • (2005) Ophthalmology Clinics of North America , vol.18 , Issue.3 , pp. 431-442
    • Ishida, K.1    Mandal, A.K.2    Netland, P.A.3
  • 9
    • 0031941892 scopus 로고    scopus 로고
    • An ultrasound biomicroscopic study of eyes after deep sclerectomy with collagen implant
    • DOI 10.1016/S0161-6420(98)94033-7
    • AGY Chiou A Mermoud JP Underdahl CC Schnydrer 1998 An ultrasound biomicroscopic study of eyeballs after deep sclerectomy with collagen implant Ophthalmology 105 746 750 1:STN:280:DyaK1c3gsVaisg%3D%3D 10.1016/S0161-6420(98) 94033-7 9544651 (Pubitemid 28180229)
    • (1998) Ophthalmology , vol.105 , Issue.4 , pp. 746-750
    • Chiou, A.G.-Y.1    Mermoud, A.2    Underdahl, J.P.3    Schnyder, C.C.4
  • 10
    • 0035989721 scopus 로고    scopus 로고
    • PVDF as a new polymer for the construction of surgical meshes
    • DOI 10.1016/S0142-9612(02)00070-4, PII S0142961202000704
    • U Klinge B Klosterhalfen AP Ottinger K Junge 2002 PVDF as a new polymer for the construction of surgical meshes Biomaterials 23 3487 3493 1:CAS:528:DC%2BD38XktFKjtLg%3D 10.1016/S0142-9612(02)00070-4 12099293 (Pubitemid 34615656)
    • (2002) Biomaterials , vol.23 , Issue.16 , pp. 3487-3493
    • Klinge, U.1    Klosterhalfen, B.2    Ottinger, A.P.3    Junge, K.4    Schumpelick, V.5
  • 11
    • 2442614983 scopus 로고    scopus 로고
    • Preparation and properties of microporous membrane from poly(vinylidene fluoride-co-tetrafluoroethylene) (F2.4) for membrane distillation
    • DOI 10.1016/j.memsci.2004.02.007, PII S0376738804001073
    • F Chunseng S Baoli L Guomin W Yonglie 2004 Preparation and properties of microporous membrane from poly(vinylidene fluoride-co- tetrafluoethylene) for membrane distillation J Memb Sci. 237 15 24 10.1016/j.memsci.2004.02.007 (Pubitemid 38638351)
    • (2004) Journal of Membrane Science , vol.237 , Issue.1-2 , pp. 15-24
    • Feng, C.1    Shi, B.2    Li, G.3    Wu, Y.4
  • 12
    • 0345863699 scopus 로고    scopus 로고
    • Comparative study between deep sclerectomy with and without collagen implant: Long term follow up
    • DOI 10.1136/bjo.88.1.95
    • T Shaarawy Cr Nguyen F Achache 2004 Comparative study between deep scleretomy with and without collagen implant: long term follow-up Br J Ophthalmol 88 1 95 98 1:STN:280:DC%2BD3snhtVWqsw%3D%3D 10.1136/bjo.88.1.95 14693783 (Pubitemid 38091372)
    • (2004) British Journal of Ophthalmology , vol.88 , Issue.1 , pp. 95-98
    • Shaarawy, T.1    Nguyen, C.2    Schnyder, C.3    Mermoud, A.4
  • 16
    • 77956938045 scopus 로고    scopus 로고
    • Composite membranes materials for ophthalmological implants
    • E Stodolak M Krok T Gumula S Blazewicz 2009 Composite membranes materials for ophthalmological implants Composites 4 352 357
    • (2009) Composites , vol.4 , pp. 352-357
    • Stodolak, E.1    Krok, M.2    Gumula, T.3    Blazewicz, S.4
  • 19
    • 3242804574 scopus 로고    scopus 로고
    • Deep sclerectomy with various implants: An experimental and histopathologic study in a rabbit model
    • DOI 10.1159/000078618
    • K Erkiliç A Ozkiriş C Evereklioglu O Kontaş K Güler H Dogan 2004 Deep sclerectomy with various implants: an experimental and histopathologic study in a rabbit model Ophthalmologica 218 264 269 10.1159/000078618 15258416 (Pubitemid 38969834)
    • (2004) Ophthalmologica , vol.218 , Issue.4 , pp. 264-269
    • Erkilic, K.1    Ozkiris, A.2    Evereklioglu, C.3    Kontas, O.4    Guler, K.5    Dogan, H.6
  • 20
    • 34247639391 scopus 로고    scopus 로고
    • Histological biocompatibility of new, non-absorbable glaucoma deep sclerectomy implant
    • JJ Kaluzny W Jozwicki H Wisniewska 2007 Histological biocompatibility of new, non-absorbable glaucoma deep sclerectomy implant J Biomed Mater Res B 81 2 403 409
    • (2007) J Biomed Mater Res B , vol.81 , Issue.2 , pp. 403-409
    • Kaluzny, J.J.1    Jozwicki, W.2    Wisniewska, H.3
  • 21
    • 43249105930 scopus 로고    scopus 로고
    • Biocompatibility of an x-shaped zirconium implant in deep sclerectomy in rabbits
    • 10.1007/s00417-008-0782-y 18305952
    • A Basso S Roy A Mermoud 2008 Biocompatibility of an x-shaped zirconium implant in deep sclerectomy in rabbits Graefes Arch Clin Exp Ophthalmol 246 6 849 855 10.1007/s00417-008-0782-y 18305952
    • (2008) Graefes Arch Clin Exp Ophthalmol , vol.246 , Issue.6 , pp. 849-855
    • Basso, A.1    Roy, S.2    Mermoud, A.3
  • 23
    • 33751514537 scopus 로고    scopus 로고
    • Outflow mechanisms after deep sclerectomy with two different designs of collagen implant in an animal model
    • DOI 10.1007/s00417-006-0275-9
    • C Nguyen RC Boldea S Roy T Shaarawy S Uffer A Mermoud 2006 Outflow mechanisms after deep sclerectomy with two different designs of collagen implant in an animal model Graefes Arch Clin Exp Ophthalmol 244 12 1659 1667 1:CAS:528:DC%2BD28Xht1enu7vP 10.1007/s00417-006-0275-9 16596406 (Pubitemid 44830827)
    • (2006) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.244 , Issue.12 , pp. 1659-1667
    • Nguyen, C.1    Boldea, R.C.2    Roy, S.3    Shaarawy, T.4    Uffer, S.5    Mermoud, A.6
  • 24
    • 0032819930 scopus 로고    scopus 로고
    • Novel synthetic meshwork for glaucoma treatment. I. Design and preliminary in vitro and in vivo evaluation of various expanded poly(tetrafluoroethylene) materials
    • DOI 10.1002/(SICI)1097-4636(199911)47:2<260::AID-JBM17>3.0.CO;2-J
    • V Jallet SE Gautier JM Parel T Matsui I Haefliger H Kondo H Kato M Savoldelli Y Pouliquen 1999 Novel synthetic meshwork for glaucoma treatment. I. Design and preliminary in vitro and in vivo evaluation of various expanded poly(tetrafluoroethylene) materials J Biomed Mater Res 47 2 260 269 1:CAS:528:DyaK1MXmtVantLo%3D 10.1002/(SICI)1097-4636(199911)47:2<260::AID- JBM17>3.0.CO;2-J 10449638 (Pubitemid 29409746)
    • (1999) Journal of Biomedical Materials Research , vol.47 , Issue.2 , pp. 260-269
    • Jallet, V.1    Gautier, S.E.2    Parel, J.-M.3    Matsui, T.4    Haefliger, I.5    Kondo, H.6    Kato, H.7    Savoldelli, M.8    Pouliquen, Y.9
  • 25
    • 33845477018 scopus 로고    scopus 로고
    • A newly designed glaucoma drainage implant made of poly(styrene-b- isobutylene-b-styrene): Biocompatibility and function in normal rabbit eyes
    • DOI 10.1001/archopht.124.12.1742
    • AC Acosta EM Espana H Yamamoto S Davis L Pinchuk BA Weber M Orozco S Dubovy F Fantes JM Parel 2006 A newly designed glaucoma drainage implant made of poly(styrene-b-isobutylene-b-styrene): biocompatibility and function in normal rabbit eyeballs Arch Ophthalmol 124 12 1742 1749 1:CAS:528: DC%2BD2sXislOmsA%3D%3D 10.1001/archopht.124.12.1742 17159034 (Pubitemid 44913198)
    • (2006) Archives of Ophthalmology , vol.124 , Issue.12 , pp. 1742-1749
    • Acosta, A.C.1    Espana, E.M.2    Yamamoto, H.3    Davis, S.4    Pinchuk, L.5    Weber, B.A.6    Orozco, M.7    Dubovy, S.8    Fantes, F.9    Parel, J.-M.10
  • 26
    • 0032919262 scopus 로고    scopus 로고
    • Biodegradable tube implants in experimental glaucoma surgery in the rabbit
    • DOI 10.1023/A:1008896211886
    • M Kivalo V Siren C Raitta I Immonen 1999 Biodegradable tube implants in experimental glaucoma surgery in the rabbit J Mater Sci Mater Med 10 1 53 58 1:CAS:528:DyaK1MXoslKisw%3D%3D 10.1023/A:1008896211886 15347994 (Pubitemid 29043888)
    • (1999) Journal of Materials Science: Materials in Medicine , vol.10 , Issue.1 , pp. 53-58
    • Kivalo, M.1    Siren, V.2    Raitta, C.3    Immonen, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.