메뉴 건너뛰기




Volumn 21, Issue 12, 2010, Pages 1379-1385

Effect of a macroscopic groove on bone response and implant stability

Author keywords

Bone to implant contact; Macroscopic groove; Rabbit tibia; Removal torque; Resonance frequency

Indexed keywords

TITANIUM;

EID: 78349275769     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2010.01960.x     Document Type: Article
Times cited : (12)

References (31)
  • 1
    • 4644241352 scopus 로고    scopus 로고
    • Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog
    • Abrahamsson, I., Berglundh, T., Linder, E., Lang, N.P. & Lindhe, J. (2004) Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog. Clinical Oral Implants Research 15: 381-392.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 381-392
    • Abrahamsson, I.1    Berglundh, T.2    Linder, E.3    Lang, N.P.4    Lindhe, J.5
  • 2
    • 0020807637 scopus 로고
    • Direct bone anchorage of dental implants
    • Albrektsson, T. (1983) Direct bone anchorage of dental implants. Journal of Prosthetic Dentistry 50: 255-261.
    • (1983) Journal of Prosthetic Dentistry , vol.50 , pp. 255-261
    • Albrektsson, T.1
  • 5
    • 37249059880 scopus 로고    scopus 로고
    • Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model
    • Al-Nawas, B., Groetz, K.A., Goetz, H., Duschner, H. & Wagner, W. (2008) Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model. Clinical Oral Implants Research 19: 1-8.
    • (2008) Clinical Oral Implants Research , vol.19 , pp. 1-8
    • Al-Nawas, B.1    Groetz, K.A.2    Goetz, H.3    Duschner, H.4    Wagner, W.5
  • 6
    • 33750554083 scopus 로고    scopus 로고
    • Insertion torque and resonance frequency analysis of dental implants systems in an animal model with loaded implants
    • Al-Nawas, B., Wagner, W. & Groetz, K.A. (2006) Insertion torque and resonance frequency analysis of dental implants systems in an animal model with loaded implants. International Journal of Oral and Maxillofacial Implants 21: 726-732.
    • (2006) International Journal of Oral and Maxillofacial Implants , vol.21 , pp. 726-732
    • Al-Nawas, B.1    Wagner, W.2    Groetz, K.A.3
  • 7
    • 33748309280 scopus 로고    scopus 로고
    • Validity and clinical significance of biomechanical testing of implant/bone interface
    • Aparicio, C., Lang, N.P. & Rangert, B. (2006) Validity and clinical significance of biomechanical testing of implant/bone interface. Clinical Oral Implants Research 17 (Suppl. 2): 2-7.
    • (2006) Clinical Oral Implants Research , vol.17 , Issue.SUPPL. 2 , pp. 2-7
    • Aparicio, C.1    Lang, N.P.2    Rangert, B.3
  • 8
    • 0018970317 scopus 로고
    • The optimum pore size for the fixation of porous-surface metal implants by the ingrowth of bone
    • Bobyn, J., Pillar, R. & Cameron, H. (1980) The optimum pore size for the fixation of porous-surface metal implants by the ingrowth of bone. Clinical Orthopaedics and Related Research 150: 263-270.
    • (1980) Clinical Orthopaedics and Related Research , vol.150 , pp. 263-270
    • Bobyn, J.1    Pillar, R.2    Cameron, H.3
  • 9
    • 0033083630 scopus 로고    scopus 로고
    • The effects of the surface topography of micromachined titanium substrata on cell behavior in vitro and in vivo
    • Brunette, D.M. & Chehroudi, B. (1999) The effects of the surface topography of micromachined titanium substrata on cell behavior in vitro and in vivo. Journal of Biomechanical Engineering 121: 49-57.
    • (1999) Journal of Biomechanical Engineering , vol.121 , pp. 49-57
    • Brunette, D.M.1    Chehroudi, B.2
  • 12
    • 0031553839 scopus 로고    scopus 로고
    • The effects of micromachined surfaces on formation of bonelike tissue on subcutaneous implants as assessed by radiography and computer image processing
    • Chehroudi, B., McDonnell, D. & Brunette, D.M. (1997) The effects of micromachined surfaces on formation of bonelike tissue on subcutaneous implants as assessed by radiography and computer image processing. Journal of Biomedical Materials Research 34: 279-290.
    • (1997) Journal of Biomedical Materials Research , vol.34 , pp. 279-290
    • Chehroudi, B.1    McDonnell, D.2    Brunette, D.M.3
  • 13
    • 0141608016 scopus 로고    scopus 로고
    • Understanding peri-implant endosseous healing
    • Davies, J.E. (2003) Understanding peri-implant endosseous healing. Journal of Dental Education 67: 932-949.
    • (2003) Journal of Dental Education , vol.67 , pp. 932-949
    • Davies, J.E.1
  • 14
    • 0019947037 scopus 로고
    • A method for the study on undecalcified bones and teeth with attached soft tissue
    • Donath, K. & Breuner, C. (1982) A method for the study on undecalcified bones and teeth with attached soft tissue. Journal of Oral Pathology 11: 318-325.
    • (1982) Journal of Oral Pathology , vol.11 , pp. 318-325
    • Donath, K.1    Breuner, C.2
  • 17
    • 0002764961 scopus 로고    scopus 로고
    • Properties of a new porous oxide surface on titanium implants
    • Hall, J. & Lausmaa, J. (2000) Properties of a new porous oxide surface on titanium implants. Applied Osseointegration Research 1: 5-8.
    • (2000) Applied Osseointegration Research , vol.1 , pp. 5-8
    • Hall, J.1    Lausmaa, J.2
  • 18
    • 20744444530 scopus 로고    scopus 로고
    • Stimulation of directed bone growth at oxidized titanium implants by macroscopic grooves
    • an in vivo study.
    • Hall, J., Miranda-Burgos, P. & Sennerby, L. (2005) Stimulation of directed bone growth at oxidized titanium implants by macroscopic grooves: an in vivo study. Clinical Implant Dentistry and Related Research 7 (Suppl. 1): s76-s82.
    • (2005) Clinical Implant Dentistry and Related Research , vol.7 , Issue.SUPPL. 1
    • Hall, J.1    Miranda-Burgos, P.2    Sennerby, L.3
  • 21
    • 0032199450 scopus 로고    scopus 로고
    • Histologic and histomorphometric analysis of the bone reponse to machined and sandblasted titanium implants
    • an experimental study in rabbits.
    • Piattelli, A., Manzon, L., Scarano, A., Paolantonio, M. & Piattelli, M. (1998) Histologic and histomorphometric analysis of the bone reponse to machined and sandblasted titanium implants: an experimental study in rabbits. International Journal of Oral and Maxillofacial Implants 13: 805-810.
    • (1998) International Journal of Oral and Maxillofacial Implants , vol.13 , pp. 805-810
    • Piattelli, A.1    Manzon, L.2    Scarano, A.3    Paolantonio, M.4    Piattelli, M.5
  • 22
    • 0032111709 scopus 로고    scopus 로고
    • The endopore implant-enhanced osseointegration with a sintered porous-surfaced design
    • Pilliar, R.M., Deporter, D.A., Watson, P.A. & Todescan, R. (1998) The endopore implant-enhanced osseointegration with a sintered porous-surfaced design. Oral Health 88: 61-64.
    • (1998) Oral Health , vol.88 , pp. 61-64
    • Pilliar, R.M.1    Deporter, D.A.2    Watson, P.A.3    Todescan, R.4
  • 24
    • 0043014563 scopus 로고    scopus 로고
    • Histology of retrieved immediately and early loaded oxidized implants. Light microscopic observations after 5 to 9 months of loading in the posterior mandible of 5 cases
    • Rocci, A., Martignoni, M., Burgos, P., Gottlow, J. & Sennerby, L. (2003) Histology of retrieved immediately and early loaded oxidized implants. Light microscopic observations after 5 to 9 months of loading in the posterior mandible of 5 cases. Clinical Implant Dentistry and Related Research 5 (Suppl 1): 88-98.
    • (2003) Clinical Implant Dentistry and Related Research , vol.5 , Issue.SUPPL 1 , pp. 88-98
    • Rocci, A.1    Martignoni, M.2    Burgos, P.3    Gottlow, J.4    Sennerby, L.5
  • 25
    • 0026826756 scopus 로고
    • A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone
    • Sennerby, L., Thomsen, P. & Ericson, L.E. (1992) A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. International Journal of Oral and Maxillofacial Implants 7: 62-71.
    • (1992) International Journal of Oral and Maxillofacial Implants , vol.7 , pp. 62-71
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 27
    • 0029268053 scopus 로고
    • A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies
    • Wennerberg, A., Albrektsson, T., Andersson, B. & Kroll, J.J. (1995) A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clinical Oral Implants Research 6: 24-30.
    • (1995) Clinical Oral Implants Research , vol.6 , pp. 24-30
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3    Kroll, J.J.4
  • 29
    • 0031994750 scopus 로고    scopus 로고
    • A histomorphometric evaluation of screw-shaped implants each prepared with two surface roughnesses
    • Wennerberg, A., Hallgren, C., Johansson, C. & Danelli, S. (1998) A histomorphometric evaluation of screw-shaped implants each prepared with two surface roughnesses. Clinical Oral Implants Research 9: 11-19.
    • (1998) Clinical Oral Implants Research , vol.9 , pp. 11-19
    • Wennerberg, A.1    Hallgren, C.2    Johansson, C.3    Danelli, S.4
  • 31
    • 0345047714 scopus 로고    scopus 로고
    • Osseous healing characteristics of three different implant types. A histologic and histomorphometric study in mini-pigs
    • Zechner, W., Tangl, S., Fürst, G., Tepper, G., Thams, U., Mailath, G. & Watzek, G. (2003) Osseous healing characteristics of three different implant types. A histologic and histomorphometric study in mini-pigs. Clinical Oral Implants Research 14: 150-157.
    • (2003) Clinical Oral Implants Research , vol.14 , pp. 150-157
    • Zechner, W.1    Tangl, S.2    Fürst, G.3    Tepper, G.4    Thams, U.5    Mailath, G.6    Watzek, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.