메뉴 건너뛰기




Volumn 64, Issue 5, 2010, Pages 1440-1445

Simultaneous quantification of T2 and T′2 using a combined gradient echo-spin echo sequence at ultrahigh field

Author keywords

7.0 T; Brain; GESSE

Indexed keywords

BRAIN; ERRORS;

EID: 78349254962     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22522     Document Type: Article
Times cited : (28)

References (25)
  • 1
    • 33847534249 scopus 로고
    • Effects of diffusion on free precession in nuclear magnetic resonance experiments
    • Carr HY, Purcell EM,. Effects of diffusion on free precession in nuclear magnetic resonance experiments. Phys Rev 1954; 94: 630-638.
    • (1954) Phys Rev , vol.94 , pp. 630-638
    • Carr, H.Y.1    Purcell, E.M.2
  • 3
    • 0022930453 scopus 로고
    • 2 using multiple-echo techniques. II. Effects of static field inhomogeneity
    • DOI 10.1002/mrm.1910030410
    • 2 using multiple-Echo MRI techniques II. Effects of static field inhomogeneity. Magn Reson Med 1986; 3: 562-574. (Pubitemid 17171953)
    • (1986) Magnetic Resonance in Medicine , vol.3 , Issue.4 , pp. 562-574
    • Majumdar, S.1    Orphanoudakis, S.C.2    Gmitro, A.3
  • 4
    • 3342959131 scopus 로고    scopus 로고
    • Rapid and accurate measurement of transverse relaxation times using a single shot multi-echo echo-planar imaging sequence
    • Tyler DJ, Moore RJ, Marciani L, Gowland PA,. Rapid and accurate measurement of transverse relaxation times using a single shot multi-echo echo-planar imaging sequence. Magn Reson Imaging 2004; 22: 1031-1037.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1031-1037
    • Tyler, D.J.1    Moore, R.J.2    Marciani, L.3    Gowland, P.A.4
  • 5
    • 0036338505 scopus 로고    scopus 로고
    • 2 by multiple acquisition of spin and gradient echoes using interleaved echo planar imaging (MASAGE-IEPI)
    • 2 by multiple acquisition of spin and gradient echoes using interleaved echo planar imaging (MASAGE-IEPI). Neuroimage 2002; 15: 992-1002.
    • (2002) Neuroimage , vol.15 , pp. 992-1002
    • Thomas, D.L.1    Lythgoe, M.F.2    Gadian, D.G.3    Ordidge, R.J.4
  • 7
    • 0030118720 scopus 로고    scopus 로고
    • Method for image-based measurement of the reversible and irreversible contribution to the transverse-relaxation rate
    • Ma J, Wehrli FW,. Method for image-based measurement of the reversible and irreversible contribution to the transverse-relaxation rate. J Magn Reson Ser B 1996; 111: 61-69.
    • (1996) J Magn Reson ser B , vol.111 , pp. 61-69
    • Ma, J.1    Wehrli, F.W.2
  • 9
    • 0030925243 scopus 로고    scopus 로고
    • An MRI method for measuring T2 in the presence of static and RF magnetic field inhomogeneities
    • Yablonskiy DA, Haacke EM,. An MRI method for measuring T2 in the presence of static and RF magnetic field inhomogeneities. Magn Reson Med 1997; 37: 872-876.
    • (1997) Magn Reson Med , vol.37 , pp. 872-876
    • Yablonskiy, D.A.1    Haacke, E.M.2
  • 10
    • 0033882689 scopus 로고    scopus 로고
    • Quantitative measurements of cerebral blood oxygen saturation using magnetic resonance imaging
    • An H, Lin W,. Quantitative measurements of cerebral blood oxygen saturation using magnetic resonance imaging. J Cereb Blood Flow Metab 2000; 20: 1225-1236.
    • (2000) J Cereb Blood Flow Metab , vol.20 , pp. 1225-1236
    • An, H.1    Lin, W.2
  • 11
    • 0027973923 scopus 로고
    • Theory of NMR signal behaviour in magnetically inhomogeneous tissues: The static dephasing regime
    • Yablonskiy DA, Haacke EM,. Theory of NMR signal behaviour in magnetically inhomogeneous tissues: The static dephasing regime. Magn Reson Med 1994; 32: 749-763.
    • (1994) Magn Reson Med , vol.32 , pp. 749-763
    • Yablonskiy, D.A.1    Haacke, E.M.2
  • 13
    • 0001008029 scopus 로고
    • Efficient method for finding minimum of function of several variables without calculating derivatives
    • Powell MJD,. Efficient method for finding minimum of function of several variables without calculating derivatives. Comput J 1964; 7: 155-162.
    • (1964) Comput J , vol.7 , pp. 155-162
    • Powell, M.J.D.1
  • 16
    • 0003449101 scopus 로고    scopus 로고
    • 2nd ed. Sausalito, CA: University Science Books
    • Taylor JR,. An introduction to error analysis, 2nd ed. Sausalito, CA: University Science Books; 1997. pp 181-226.
    • (1997) An Introduction to Error Analysis , pp. 181-226
    • Taylor, J.R.1
  • 19
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM,. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985; 12: 232-233.
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 20
    • 0033013737 scopus 로고    scopus 로고
    • MR Imaging of human brain at 3.0T: Preliminary report on transverse relaxation rates and relation to estimated iron content
    • Gelman N, Gorell JM, Barker PB, Savage RM, Spickler EM, Windman JP, Knight RA,. MR Imaging of human brain at 3.0T: Preliminary report on transverse relaxation rates and relation to estimated iron content. Radiology 1999; 210: 759-767.
    • (1999) Radiology , vol.210 , pp. 759-767
    • Gelman, N.1    Gorell, J.M.2    Barker, P.B.3    Savage, R.M.4    Spickler, E.M.5    Windman, J.P.6    Knight, R.A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.