메뉴 건너뛰기




Volumn 6361 LNCS, Issue PART 1, 2010, Pages 526-533

Patient specific models for planning and guidance of minimally invasive aortic valve implantation

Author keywords

[No Author keywords available]

Indexed keywords

AORTIC VALVES; AUTOMATIC SEGMENTATIONS; CLINICAL MEASUREMENTS; CT IMAGE; LEAVE-ONE-OUT; MINIMALLY INVASIVE; MODEL ADAPTATION; MODEL-BASED METHOD; MODEL-BASED SEGMENTATION; PATIENT SPECIFIC MODEL; PLANNING TOOLS; ROOT-MEAN SQUARE ERRORS; SURFACE ERROR; VALIDATION RESULTS;

EID: 78349253437     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-15705-9_64     Document Type: Conference Paper
Times cited : (44)

References (11)
  • 1
    • 10744220322 scopus 로고    scopus 로고
    • Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis
    • Cribier, et al.: Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. J. Am. Coll. Cardiol. 43(4), 698-703 (2004)
    • (2004) J. Am. Coll. Cardiol. , vol.43 , Issue.4 , pp. 698-703
    • Cribier1
  • 2
    • 34748910153 scopus 로고    scopus 로고
    • Transapical minimally invasive aortic valve implantation: Multicenter experience
    • Walther, et al.: Transapical minimally invasive aortic valve implantation: multicenter experience. Circulation 116(11 Suppl.), 1240-1245 (2007)
    • (2007) Circulation , vol.116 , Issue.11 SUPPL. , pp. 1240-1245
    • Walther1
  • 3
    • 43449083449 scopus 로고    scopus 로고
    • Automatic model-based egmentation of the heart in CT images
    • Ecabert, et al.: Automatic model-based egmentation of the heart in CT images. IEEE TMI 27(9), 1189-1201 (2008)
    • (2008) IEEE TMI , vol.27 , Issue.9 , pp. 1189-1201
    • Ecabert1
  • 4
    • 84862246782 scopus 로고    scopus 로고
    • Dynamic model-driven quantitative and visual evaluation of the aortic valve from 4D CT
    • Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part I. Springer, Heidelberg
    • Ionasec, et al.: Dynamic model-driven quantitative and visual evaluation of the aortic valve from 4D CT. In: Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part I. LNCS, vol. 5241, pp. 686-694. Springer, Heidelberg (2008)
    • (2008) LNCS , vol.5241 , pp. 686-694
    • Ionasec1
  • 5
    • 43649086862 scopus 로고    scopus 로고
    • Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement
    • Tops, et al.: Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovascular Imaging 1(3), 321-330 (2008)
    • (2008) JACC Cardiovascular Imaging , vol.1 , Issue.3 , pp. 321-330
    • Tops1
  • 6
    • 67149127040 scopus 로고    scopus 로고
    • A planning system for transapical aortic valve implantation
    • Gessat, et al.: A planning system for transapical aortic valve implantation. SPIE Medical Imaging 7261, 72611E.1-72611E.12 (2009)
    • (2009) SPIE Medical Imaging , vol.7261
    • Gessat1
  • 7
    • 43449113899 scopus 로고    scopus 로고
    • Segmentation of the heart and major vascular structures in cardiovascular CT images
    • Peters, et al.: Segmentation of the heart and major vascular structures in cardiovascular CT images. SPIE Medical Imaging 6914, 691417.1-691417.12 (2008)
    • (2008) SPIE Medical Imaging , vol.6914
    • Peters1
  • 8
    • 70450270659 scopus 로고    scopus 로고
    • Optimizing boundary detection via simulated search with applications to multi-modal heart segmentation
    • Peters, et al.: Optimizing boundary detection via simulated search with applications to multi-modal heart segmentation. Medical Image Analysis 14(1), 70-84 (2010)
    • (2010) Medical Image Analysis , vol.14 , Issue.1 , pp. 70-84
    • Peters1
  • 9
    • 0032660758 scopus 로고    scopus 로고
    • Direct least square fitting of ellipses
    • Fitzgibbon, et al.: Direct least square fitting of ellipses. IEEE Trans. PAMI 21(5), 476-480 (1999)
    • (1999) IEEE Trans. PAMI , vol.21 , Issue.5 , pp. 476-480
    • Fitzgibbon1
  • 10
    • 73649096192 scopus 로고    scopus 로고
    • Multimodal assessment of the aortic annulus diameter: Implications for transcatheter aortic valve implantation
    • Messika-Zeitoun, et al.: Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J. Am. Coll. Cardiol. 55(3), 186-194 (2010)
    • (2010) J. Am. Coll. Cardiol. , vol.55 , Issue.3 , pp. 186-194
    • Messika-Zeitoun1
  • 11
    • 67149136732 scopus 로고    scopus 로고
    • Localization and tracking of aortic valve prosthesis in 2D fluoroscopic image sequences
    • Karar, et al.: Localization and tracking of aortic valve prosthesis in 2D fluoroscopic image sequences. SPIE Medical Imaging 7261, 72611Q.1-72611Q.8 (2009)
    • (2009) SPIE Medical Imaging , vol.7261
    • Karar1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.