메뉴 건너뛰기




Volumn 64, Issue 5, 2010, Pages 1373-1381

Motion correction in MR thermometry of abdominal organs: A comparison of the referenceless vs. the multibaseline approach

Author keywords

Artifacts; Correction; Susceptibility; Technical research; Technique development

Indexed keywords

ABLATION; DISPLACEMENT MEASUREMENT; ELECTRIC POWER FACTOR CORRECTION; MAGNETIC RESONANCE; MAGNETIC SUSCEPTIBILITY; NATURAL FREQUENCIES; THERMOMETERS; ULTRASONIC APPLICATIONS;

EID: 78349250151     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22514     Document Type: Article
Times cited : (56)

References (17)
  • 3
    • 0242290981 scopus 로고    scopus 로고
    • Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion
    • Vigen KK, Daniel BL, Pauly JM, Butts K,. Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion. Magn Reson Med 2003; 50: 1003-1010.
    • (2003) Magn Reson Med , vol.50 , pp. 1003-1010
    • Vigen, K.K.1    Daniel, B.L.2    Pauly, J.M.3    Butts, K.4
  • 4
    • 33846815451 scopus 로고    scopus 로고
    • Real time adaptive methods for treatment of mobile organs by MRI controlled high intensity focused ultrasound
    • Denis de Senneville B, Mougenot C,. Real time adaptive methods for treatment of mobile organs by MRI controlled high intensity focused ultrasound. Magn Reson Med 2007; 57: 319-330.
    • (2007) Magn Reson Med , vol.57 , pp. 319-330
    • Denis De Senneville, B.1    Mougenot, C.2
  • 9
    • 33845368376 scopus 로고    scopus 로고
    • Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field
    • El-Sharkawy AM, Schar M, Bottomley PA, Atalar E,. Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field. MAGMA 2006; 19: 223-236.
    • (2006) MAGMA , vol.19 , pp. 223-236
    • El-Sharkawy, A.M.1    Schar, M.2    Bottomley, P.A.3    Atalar, E.4
  • 10
    • 0030226675 scopus 로고    scopus 로고
    • Recent technical advances in MR imaging of the abdomen
    • Riederer SJ,. Recent technical advances in MR imaging of the abdomen. J Magn Res Imaging 1996; 6: 822-832.
    • (1996) J Magn Res Imaging , vol.6 , pp. 822-832
    • Riederer, S.J.1
  • 11
    • 0025102147 scopus 로고
    • Signal to noise in phase angle reconstruction: Dynamic range extension using phase reference offsets
    • Conturo TE, Smith GD,. Signal to noise in phase angle reconstruction: dynamic range extension using phase reference offsets. Magn Res Med 1990; 15: 420-437.
    • (1990) Magn Res Med , vol.15 , pp. 420-437
    • Conturo, T.E.1    Smith, G.D.2
  • 12
    • 53549111059 scopus 로고    scopus 로고
    • Evaluation of referenceless thermometry in MRI-guided focused ultrasound surgery of uterine fibroids
    • McDannold N, Tempany CM, Jolesz F, Hynynen K,. Evaluation of referenceless thermometry in MRI-guided focused ultrasound surgery of uterine fibroids. J Magn Reson Imaging 2008; 28: 1026-1032.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1026-1032
    • McDannold, N.1    Tempany, C.M.2    Jolesz, F.3    Hynynen, K.4
  • 13
    • 0036668838 scopus 로고    scopus 로고
    • Understanding phase maps in MRI: A new cutline phase unwrapping method
    • Chavez S, Xiang QS, An L,. Understanding phase maps in MRI: a new cutline phase unwrapping method. IEEE Trans Med Imaging 2002; 21: 966-977.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 966-977
    • Chavez, S.1    Xiang, Q.S.2    An, L.3
  • 16
    • 0031848730 scopus 로고    scopus 로고
    • Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry
    • Peters RD, Hinks RS, Henkelman RM,. Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magn Reson Med 1998; 40: 454-459.
    • (1998) Magn Reson Med , vol.40 , pp. 454-459
    • Peters, R.D.1    Hinks, R.S.2    Henkelman, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.