메뉴 건너뛰기




Volumn 11, Issue 5, 2010, Pages 532-536

Facilitated anastomosis using a reverse thermo-sensitive polymer for temporary coronary occlusion in off-pump minimally invasive direct coronary artery bypass surgery

Author keywords

Coronary occlusion; Minimally invasive direct coronary artery bypass; Off pump coronary artery bypass

Indexed keywords

CARBON DIOXIDE; CREATINE KINASE MB; POLOXAMER;

EID: 78149474651     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2010.233916     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 56049120826 scopus 로고    scopus 로고
    • Shunt or snare: Coronary endothelial damage due to hemostatic devices for beating heart coronary surgery
    • Hangler H, Mueller L, Ruttmann E. Shunt or snare: coronary endothelial damage due to hemostatic devices for beating heart coronary surgery. Ann Thorac Surg 2008;86:1873-1877.
    • (2008) Ann Thorac Surg , vol.86 , pp. 1873-1877
    • Hangler, H.1    Mueller, L.2    Ruttmann, E.3
  • 2
    • 0038386594 scopus 로고    scopus 로고
    • Influence of intracoronary shunt size on coronary endothelial function during off-pump coronary artery bypass
    • Demaria RO, Fortier S, Malo O. Influence of intracoronary shunt size on coronary endothelial function during off-pump coronary artery bypass. Heart Surg Forum 2003;6:160-168.
    • (2003) Heart Surg Forum , vol.6 , pp. 160-168
    • Demaria, R.O.1    Fortier, S.2    Malo, O.3
  • 3
  • 4
    • 0034993953 scopus 로고    scopus 로고
    • Coronary endothelial damage during off-pump CABG related to coronary-clamping and gas insufflation
    • Okazaki Y, Takarabe K, Murayama J. Coronary endothelial damage during off-pump CABG related to coronary-clamping and gas insufflation. Eur J Cardiothorac Surg 2001;19:834-839.
    • (2001) Eur J Cardiothorac Surg , vol.19 , pp. 834-839
    • Okazaki, Y.1    Takarabe, K.2    Murayama, J.3
  • 5
    • 33750087543 scopus 로고    scopus 로고
    • Temporary coronary artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction in epicardial coronary arteries
    • Bouchot O, Aubin MC, Carrier M, Cohn WE, Perrault LP. Temporary coronary artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction in epicardial coronary arteries. J Thorac Cardiovasc Surg 2006;132:1144-1149.
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 1144-1149
    • Bouchot, O.1    Aubin, M.C.2    Carrier, M.3    Cohn, W.E.4    Perrault, L.P.5
  • 6
    • 33747771786 scopus 로고    scopus 로고
    • Temporary internal thoracic artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction
    • Aubin MC, Bouchot O, Carrier M, Cohn WE, Perrault LP. Temporary internal thoracic artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction. J Thorac Cardiovasc Surg 2006;132:685-686.
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 685-686
    • Aubin, M.C.1    Bouchot, O.2    Carrier, M.3    Cohn, W.E.4    Perrault, L.P.5
  • 7
    • 35048884638 scopus 로고    scopus 로고
    • Use of the purified poloxamer 407 for temporary coronary occlusion in off-pump CABG does not cause myocardial injury
    • Mommerot A, Aubin MC, Carrier M, Cohn WE, Perrault LP. Use of the purified poloxamer 407 for temporary coronary occlusion in off-pump CABG does not cause myocardial injury. Innovations 2007;2:201-204.
    • (2007) Innovations , vol.2 , pp. 201-204
    • Mommerot, A.1    Aubin, M.C.2    Carrier, M.3    Cohn, W.E.4    Perrault, L.P.5
  • 10
    • 77950971441 scopus 로고    scopus 로고
    • Thermosensitive polymer use for shunt sealing in off-pump coronary artery bypass
    • Agostini M, Lemut F, DiGregorio V, Grossi C. Thermosensitive polymer use for shunt sealing in off-pump coronary artery bypass. Innovations 2010;5:122-124.
    • (2010) Innovations , vol.5 , pp. 122-124
    • Agostini, M.1    Lemut, F.2    Digregorio, V.3    Grossi, C.4
  • 14
    • 58149377918 scopus 로고    scopus 로고
    • Evaluation of a novel reverse thermosensitive polymer for use in microvascular surgery
    • Manchio JV, Litchfield CR, Zeheb R, Bryan DJ. Evaluation of a novel reverse thermosensitive polymer for use in microvascular surgery. J Reconstr Microsurg 2009;25:69-76.
    • (2009) J Reconstr Microsurg , vol.25 , pp. 69-76
    • Manchio, J.V.1    Litchfield, C.R.2    Zeheb, R.3    Bryan, D.J.4
  • 15
    • 69949096475 scopus 로고    scopus 로고
    • Temporary segmental renal artery occlusion using reverse phase polymer for bloodless robotic partial nephrectomy
    • Moinzadeh A, Flacke S, Libertino JA, Merhige J, Vogel JM, Lyall K, Bakal CW, Madras PN. Temporary segmental renal artery occlusion using reverse phase polymer for bloodless robotic partial nephrectomy. J Urol 2009;182:1582-1587.
    • (2009) J Urol , vol.182 , pp. 1582-1587
    • Moinzadeh, A.1    Flacke, S.2    Libertino, J.A.3    Merhige, J.4    Vogel, J.M.5    Lyall, K.6    Bakal, C.W.7    Madras, P.N.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.