메뉴 건너뛰기




Volumn 395, Issue 7, 2010, Pages 893-899

Surgical anatomy and neurophysiology of the vagus nerve (VN) for standardised intraoperative neuromonitoring (IONM) of the inferior laryngeal nerve (ILN) during thyroidectomy

Author keywords

Morbidity; Neuromonitoring; Recurrent laryngeal nerve; Thyroid surgery; Vagus nerve

Indexed keywords

ACCURACY; ADULT; AGE; AGED; ARTICLE; CLINICAL TRIAL; COMMON CAROTID ARTERY; ELECTROMYOGRAPHY; FALSE NEGATIVE RESULT; FEMALE; HUMAN; INFERIOR LARYNGEAL NERVE; INFERIOR LARYNGEAL NERVE STIMULATION; INTERNAL JUGULAR VEIN; INTRAOPERATIVE NEUROMONITORING; LARYNGEAL NERVE; LARYNGOSCOPY; MAJOR CLINICAL STUDY; MALE; MORBIDITY; NERVE FUNCTION; NERVE STIMULATION; NEUROPHYSIOLOGY; OPERATION DURATION; ORGAN SIZE; PATIENT MONITORING; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RECURRENT LARYNGEAL NERVE PALSY; SEX RATIO; STANDARDIZATION; SURGICAL ANATOMY; THERMAL INJURY; THYROID GLAND VOLUME; THYROIDECTOMY; VAGUS NERVE; VAGUS NERVE STIMULATION; VOCAL CORD; WAVEFORM; WOUND CLOSURE;

EID: 78149413246     PISSN: 14352443     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00423-010-0693-3     Document Type: Article
Times cited : (58)

References (16)
  • 1
    • 0344880324 scopus 로고
    • Injuries to the recurrent laryngeal nerve in thyroid operations: Their management and avoidance
    • 1:STN:280:DC%2BD2srkt1ehsA%3D%3D 10.1097/00000658-193810000-00006 17857252
    • FH Lahey WB Hoover 1938 Injuries to the recurrent laryngeal nerve in thyroid operations: their management and avoidance Ann Surg 108 4 545 562 1:STN:280:DC%2BD2srkt1ehsA%3D%3D 10.1097/00000658-193810000-00006 17857252
    • (1938) Ann Surg , vol.108 , Issue.4 , pp. 545-562
    • Lahey, F.H.1    Hoover, W.B.2
  • 2
    • 51449087796 scopus 로고    scopus 로고
    • Complications to thyroid surgery: Results as reported in a database from a multicenter audit comprising 3,660 patients
    • 1:STN:280:DC%2BD1crosFKquw%3D%3D 10.1007/s00423-008-0366-7 18633639
    • A Bergenfelz S Jansson A Kristoffersson 2008 Complications to thyroid surgery: results as reported in a database from a multicenter audit comprising 3,660 patients Langenbecks Arch Surg 393 5 667 673 1:STN:280: DC%2BD1crosFKquw%3D%3D 10.1007/s00423-008-0366-7 18633639
    • (2008) Langenbecks Arch Surg , vol.393 , Issue.5 , pp. 667-673
    • Bergenfelz, A.1    Jansson, S.2    Kristoffersson, A.3
  • 3
    • 0029935617 scopus 로고    scopus 로고
    • Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve
    • DOI 10.1097/00005537-199604000-00010
    • DW Eisele 1996 Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve Laryngoscope 106 4 443 449 1:STN:280: DyaK287psVKgug%3D%3D 10.1097/00005537-199604000-00010 8614219 (Pubitemid 26120128)
    • (1996) Laryngoscope , vol.106 , Issue.4 , pp. 443-449
    • Eisele, D.W.1
  • 4
    • 61749093843 scopus 로고    scopus 로고
    • Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy
    • 10.1002/bjs.6417 19177420
    • M Barczyński A Konturek S Cichoń 2009 Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy Br J Surg 96 3 240 246 10.1002/bjs.6417 19177420
    • (2009) Br J Surg , vol.96 , Issue.3 , pp. 240-246
    • Barczyński, M.1    Konturek, A.2    Cichoń, S.3
  • 5
    • 0036295835 scopus 로고    scopus 로고
    • Intraoperative neuromonitoring of surgery for benign goiter
    • DOI 10.1016/S0002-9610(02)00856-5, PII S0002961002008565
    • O Thomusch C Sekulla G Walls A Machens H Dralle 2002 Intraoperative neuromonitoring of surgery for benign goiter Am J Surg 183 6 673 678 10.1016/S0002-9610(02)00856-5 12095600 (Pubitemid 34722536)
    • (2002) American Journal of Surgery , vol.183 , Issue.6 , pp. 673-678
    • Thomusch, O.1    Sekulla, C.2    Walls, G.3    Machens, A.4    Dralle, H.5
  • 6
    • 45849145724 scopus 로고    scopus 로고
    • Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery
    • German IONM Study Group. 1:STN:280:DC%2BD1cvosFyjug%3D%3D 10.1007/s00268-008-9483-2 18305996
    • H Dralle C Sekulla K Lorenz M Brauckhoff A Machens German IONM Study Group 2008 Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery World J Surg 32 7 1358 1366 1:STN:280:DC%2BD1cvosFyjug%3D%3D 10.1007/s00268-008-9483-2 18305996
    • (2008) World J Surg , vol.32 , Issue.7 , pp. 1358-1366
    • Dralle, H.1    Sekulla, C.2    Lorenz, K.3    Brauckhoff, M.4    MacHens, A.5
  • 7
    • 77949264175 scopus 로고    scopus 로고
    • Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation
    • 10.1007/s00268-009-0316-8 20020124
    • FY Chiang KW Lee HC Chen HY Chen IC Lu WR Kuo MC Hsieh CW Wu 2010 Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation World J Surg 34 2 223 229 10.1007/s00268-009-0316-8 20020124
    • (2010) World J Surg , vol.34 , Issue.2 , pp. 223-229
    • Chiang, F.Y.1    Lee, K.W.2    Chen, H.C.3    Chen, H.Y.4    Lu, I.C.5    Kuo, W.R.6    Hsieh, M.C.7    Wu, C.W.8
  • 8
    • 67349116369 scopus 로고    scopus 로고
    • Feasibility of intraoperative neuromonitoring during thyroid surgery after administration of nondepolarizing neuromuscular blocking agents
    • 10.1007/s00268-009-0049-8 19430831
    • KS Chu SH Wu IC Lu CJ Tsai CW Wu WR Kuo KW Lee FY Chiang 2009 Feasibility of intraoperative neuromonitoring during thyroid surgery after administration of nondepolarizing neuromuscular blocking agents World J Surg 33 7 1408 1413 10.1007/s00268-009-0049-8 19430831
    • (2009) World J Surg , vol.33 , Issue.7 , pp. 1408-1413
    • Chu, K.S.1    Wu, S.H.2    Lu, I.C.3    Tsai, C.J.4    Wu, C.W.5    Kuo, W.R.6    Lee, K.W.7    Chiang, F.Y.8
  • 9
    • 49749126350 scopus 로고    scopus 로고
    • Optimal depth of NIM EMG endotracheal tube for intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy
    • 10.1007/s00268-008-9549-1 18392652
    • IC Lu KS Chu CJ Tsai CW Wu WR Kuo HY Chen KW Lee FY Chiang 2008 Optimal depth of NIM EMG endotracheal tube for intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy World J Surg 32 9 1935 1939 10.1007/s00268-008-9549-1 18392652
    • (2008) World J Surg , vol.32 , Issue.9 , pp. 1935-1939
    • Lu, I.C.1    Chu, K.S.2    Tsai, C.J.3    Wu, C.W.4    Kuo, W.R.5    Chen, H.Y.6    Lee, K.W.7    Chiang, F.Y.8
  • 10
    • 63449142196 scopus 로고    scopus 로고
    • What is the learning curve for intraoperative neuromonitoring in thyroid surgery?
    • 10.1016/j.ijsu.2008.12.023
    • G Dionigi A Bacuzzi L Boni F Rovera R Dionigi 2008 What is the learning curve for intraoperative neuromonitoring in thyroid surgery? Int J Surg 6 Suppl 1 S7 S12 10.1016/j.ijsu.2008.12.023
    • (2008) Int J Surg , vol.6 , Issue.1
    • Dionigi, G.1    Bacuzzi, A.2    Boni, L.3    Rovera, F.4    Dionigi, R.5
  • 11
    • 4744347731 scopus 로고    scopus 로고
    • Recurrent laryngeal nerve identification and assessment during thyroid surgery: Laryngeal palpation
    • DOI 10.1007/s00268-004-7348-x
    • GW Randolph JB Kobler J Wilkins 2004 Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation World J Surg 28 8 755 760 10.1007/s00268-004-7348-x 15457354 (Pubitemid 39315390)
    • (2004) World Journal of Surgery , vol.28 , Issue.8 , pp. 755-760
    • Randolph, G.W.1    Kobler, J.B.2    Wilkins, J.3
  • 12
    • 78149411886 scopus 로고    scopus 로고
    • Investigation of optimal intensity and safety of electrical nerve stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve: A prospective porcine model
    • in press
    • Wu CW, Lu IC, Randolph GW, Kuo WR, Lee KW, Chen CL, Chiang FY (2010) Investigation of optimal intensity and safety of electrical nerve stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve: a prospective porcine model. Head Neck (in press)
    • (2010) Head Neck
    • Wu, C.W.1    Lu, I.C.2    Randolph, G.W.3    Kuo, W.R.4    Lee, K.W.5    Chen, C.L.6    Chiang, F.Y.7
  • 13
    • 0003625276 scopus 로고    scopus 로고
    • Federative Committee of Anatomical Terminology. Georg Thieme Stuttgart
    • Federative Committee of Anatomical Terminology (1998) Terminologia Anatomica. Georg Thieme, Stuttgart
    • (1998) Terminologia Anatomica
  • 14
    • 33646593778 scopus 로고    scopus 로고
    • Pitfalls of intraoperative neuromonitoring for predicting postoperative recurrent laryngeal nerve function during thyroidectomy
    • 10.1007/s00268-005-0355-8
    • WF Chan CY Lo 2001 Pitfalls of intraoperative neuromonitoring for predicting postoperative recurrent laryngeal nerve function during thyroidectomy World J Surg 30 806 812 10.1007/s00268-005-0355-8
    • (2001) World J Surg , vol.30 , pp. 806-812
    • Chan, W.F.1    Lo, C.Y.2
  • 16
    • 0025245451 scopus 로고
    • Anatomical, physiological, and theoretical basis for the antiepileptic effect of vagus nerve stimulation
    • 10.1111/j.1528-1157.1990.tb05843.x 2226360
    • P Rutecki 1990 Anatomical, physiological, and theoretical basis for the antiepileptic effect of vagus nerve stimulation Epilepsia 31 Suppl 2 S1 S6 10.1111/j.1528-1157.1990.tb05843.x 2226360
    • (1990) Epilepsia , vol.31 , Issue.SUPPL. 2
    • Rutecki, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.