메뉴 건너뛰기




Volumn 19, Issue 8, 2010, Pages 1175-1183

Hand-held dynamometer testing of the internal and external rotator musculature based on selected positions to establish normative data and unilateral ratios

Author keywords

Basic Science Study; Isometric; Muscle strength; Reference values; Rotator cuff; Shoulder evaluation; Shoulder joint

Indexed keywords

ARM MOVEMENT; ARM MUSCLE; ARTICLE; DYNAMOMETER; DYNAMOMETRY; HAND HELD DYNAMOMETER; HUMAN; MUSCLE STRENGTH; MUSCLE WEAKNESS; NORMAL HUMAN; PRIORITY JOURNAL; RATING SCALE; REFERENCE VALUE; ROTATION; ROTATOR CUFF; ROTATOR CUFF INJURY; SHOULDER;

EID: 78149412483     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2010.05.021     Document Type: Article
Times cited : (64)

References (32)
  • 1
    • 0023251119 scopus 로고
    • Strength testing with a portable dynamometer: Reliability for Upper and Lower Extremities
    • Agre J., Magness J., Hull S., Wright K., Baxter T., Patterson R., et al. Strength testing with a portable dynamometer: Reliability for Upper and Lower Extremities. Arch Phys Med Rehabil 1987, 68:454-458.
    • (1987) Arch Phys Med Rehabil , vol.68 , pp. 454-458
    • Agre, J.1    Magness, J.2    Hull, S.3    Wright, K.4    Baxter, T.5    Patterson, R.6
  • 2
    • 0029963026 scopus 로고    scopus 로고
    • Normative values for isometric muscle force measurements obtained with hand held dynamometers
    • Andrews A., Thomas M., Bohannon R. Normative values for isometric muscle force measurements obtained with hand held dynamometers. Phys Ther 1996, 76:248-259.
    • (1996) Phys Ther , vol.76 , pp. 248-259
    • Andrews, A.1    Thomas, M.2    Bohannon, R.3
  • 3
    • 0033142801 scopus 로고    scopus 로고
    • Intertester reliability of hand-held dynamometry: a concise summary of published research
    • Bohannon R. Intertester reliability of hand-held dynamometry: a concise summary of published research. Percept Mot Skills 1999, 88:899-902. 10.2466/PMS.88.3.899-902.
    • (1999) Percept Mot Skills , vol.88 , pp. 899-902
    • Bohannon, R.1
  • 4
    • 0031021783 scopus 로고    scopus 로고
    • Reference values for extremity muscle strength obtained by hand-held dynamometer from adults aged 20-79 years
    • Bohannon R. Reference values for extremity muscle strength obtained by hand-held dynamometer from adults aged 20-79 years. Arch Phys Med Rehabil 1997, 78:26-32. 10.1016/S0003-9993(97)90005-8.
    • (1997) Arch Phys Med Rehabil , vol.78 , pp. 26-32
    • Bohannon, R.1
  • 5
    • 0022538186 scopus 로고
    • Upper extremity strength and strength relationships among young women
    • Bohannon R. Upper extremity strength and strength relationships among young women. J Orthop Sports Phys Ther 1986, 8:128-133.
    • (1986) J Orthop Sports Phys Ther , vol.8 , pp. 128-133
    • Bohannon, R.1
  • 6
    • 0025361051 scopus 로고
    • Hand-held dynamometry: A single trial may be adequate for measuring muscle strength in healthy individuals
    • Bohannon R., Sauders N. Hand-held dynamometry: A single trial may be adequate for measuring muscle strength in healthy individuals. Physiother Canada 1990, 42:6-9.
    • (1990) Physiother Canada , vol.42 , pp. 6-9
    • Bohannon, R.1    Sauders, N.2
  • 7
    • 0024244230 scopus 로고
    • Upper extremity range of motion and isokinetic strength of the internal and external shoulder rotators in major league baseball players
    • Brown L., Niehues S., Harrah A., Yavorsky P., Horshman H. Upper extremity range of motion and isokinetic strength of the internal and external shoulder rotators in major league baseball players. Am J Sports Med 1988, 16:577-585. 10.1177/036354658801600604.
    • (1988) Am J Sports Med , vol.16 , pp. 577-585
    • Brown, L.1    Niehues, S.2    Harrah, A.3    Yavorsky, P.4    Horshman, H.5
  • 9
    • 0033818444 scopus 로고    scopus 로고
    • Assessment of shoulder strength in professional baseball pitchers
    • Donatelli R., Ellenbecker T., Ekedahl S. Assessment of shoulder strength in professional baseball pitchers. J Orthop Sports Phys Ther 2000, 30:544-551.
    • (2000) J Orthop Sports Phys Ther , vol.30 , pp. 544-551
    • Donatelli, R.1    Ellenbecker, T.2    Ekedahl, S.3
  • 11
    • 13844255523 scopus 로고    scopus 로고
    • Effect of abducting and adducting muscle activity on glenohumeral translation, scapular kinematics and subacromial space width in vivo
    • Graichen H., Hinterwimmer S., von Eisenhart-Rothe R., Vogl T., Englmeier K., Eckstein F. Effect of abducting and adducting muscle activity on glenohumeral translation, scapular kinematics and subacromial space width in vivo. J Biomech 2005, 38:755-760. 10.1016/j.jbiomech.2004.05.020.
    • (2005) J Biomech , vol.38 , pp. 755-760
    • Graichen, H.1    Hinterwimmer, S.2    von Eisenhart-Rothe, R.3    Vogl, T.4    Englmeier, K.5    Eckstein, F.6
  • 12
    • 0036369386 scopus 로고    scopus 로고
    • Reliability of 3 methods for assessing shoulder strength
    • Hayes K., Walton J., Szomar Z., Murcell G. Reliability of 3 methods for assessing shoulder strength. J Shoulder Elbow Surg 2002, 11:33-39. 10.1067/mse.2002.119852.
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 33-39
    • Hayes, K.1    Walton, J.2    Szomar, Z.3    Murcell, G.4
  • 14
    • 0032877323 scopus 로고    scopus 로고
    • Age-related changes in normal isometric shoulder strength
    • Hughes R., Johnson M., O'Driscoll S., An K- N. Age-related changes in normal isometric shoulder strength. Am J Sports Med 1999, 27:651-657.
    • (1999) Am J Sports Med , vol.27 , pp. 651-657
    • Hughes, R.1    Johnson, M.2    O'Driscoll, S.3    An K-, N.4
  • 15
    • 0032853950 scopus 로고    scopus 로고
    • Normative values of agonist-antagonist shoulder strength ratios of adults aged 20 to 78 Years
    • Hughes R., Johnson M., O'Driscoll S., An K- N. Normative values of agonist-antagonist shoulder strength ratios of adults aged 20 to 78 Years. Arch Phys Med Rehabil 1999, 80:1324-1326. 10.1016/S0003-9993(99)90037-0.
    • (1999) Arch Phys Med Rehabil , vol.80 , pp. 1324-1326
    • Hughes, R.1    Johnson, M.2    O'Driscoll, S.3    An K-, N.4
  • 17
    • 60549110508 scopus 로고    scopus 로고
    • Shoulder strength in asymptomatic individuals with intact compared with torn rotator cuffs
    • Kim H., Teefey S., Zelig A., Galtz L., Keener J., Yamaguchi K. Shoulder strength in asymptomatic individuals with intact compared with torn rotator cuffs. J Bone Joint Surg 2009, 91:289-296. 10.2106/JBJS.H.00219.
    • (2009) J Bone Joint Surg , vol.91 , pp. 289-296
    • Kim, H.1    Teefey, S.2    Zelig, A.3    Galtz, L.4    Keener, J.5    Yamaguchi, K.6
  • 18
    • 1542503450 scopus 로고    scopus 로고
    • American Psychological Association, Washington, DC, (ISBN: 1-59147-118-4)
    • Kline R. Beyond significance testing 2004, American Psychological Association, Washington, DC, p. 95-142. (ISBN: 1-59147-118-4).
    • (2004) Beyond significance testing , pp. 95-142
    • Kline, R.1
  • 19
    • 34249742657 scopus 로고    scopus 로고
    • The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device
    • Kolber M., Beekhuizen K., Cheng M., Fiebert I. The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device. Physiother Theory Pract 2007, 23:119-124. 10.1080/09593980701213032.
    • (2007) Physiother Theory Pract , vol.23 , pp. 119-124
    • Kolber, M.1    Beekhuizen, K.2    Cheng, M.3    Fiebert, I.4
  • 20
    • 34249748902 scopus 로고    scopus 로고
    • Strength testing using hand-held dynamometry
    • Kolber M., Cleland J. Strength testing using hand-held dynamometry. Phys Ther Rev 2007, 10:99-112. 10.1179/108331905X55730.
    • (2007) Phys Ther Rev , vol.10 , pp. 99-112
    • Kolber, M.1    Cleland, J.2
  • 21
    • 0029678279 scopus 로고    scopus 로고
    • Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength
    • Leggin B., Neuman R., Iannotti J., Williams G., Thompson E. Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength. J Shoulder Elbow Surg 1996, 5:18-24.
    • (1996) J Shoulder Elbow Surg , vol.5 , pp. 18-24
    • Leggin, B.1    Neuman, R.2    Iannotti, J.3    Williams, G.4    Thompson, E.5
  • 22
    • 0030980546 scopus 로고    scopus 로고
    • Assessment of isokinetic and hand-held dynamometer measures of shoulder rotation strength among individuals with spinal cord injury
    • May L., Burnham R., Steadward R. Assessment of isokinetic and hand-held dynamometer measures of shoulder rotation strength among individuals with spinal cord injury. Arch Phys Med Rehabil 1997, 78:251-255. 10.1016/S0003-9993(97)90029-0.
    • (1997) Arch Phys Med Rehabil , vol.78 , pp. 251-255
    • May, L.1    Burnham, R.2    Steadward, R.3
  • 23
    • 0028918886 scopus 로고
    • Rotator-cuff changes in asymptomatic adults. The effect of age, hand dominance and gender
    • Milgrom C., Schaffler M., Gilbert S., van Holsbeeck M. Rotator-cuff changes in asymptomatic adults. The effect of age, hand dominance and gender. J Bone Joint Surg 1995, 77:29-298.
    • (1995) J Bone Joint Surg , vol.77 , pp. 29-298
    • Milgrom, C.1    Schaffler, M.2    Gilbert, S.3    van Holsbeeck, M.4
  • 24
    • 10344230531 scopus 로고    scopus 로고
    • Isokinetic profile of shoulder internal and external rotators of high school aged baseball players
    • Mulligan I., Biddington W., Barnhart B., Ellenbacker T. Isokinetic profile of shoulder internal and external rotators of high school aged baseball players. J Strength Cond Res 2004, 18:861-866. 10.1519/14633.1.
    • (2004) J Strength Cond Res , vol.18 , pp. 861-866
    • Mulligan, I.1    Biddington, W.2    Barnhart, B.3    Ellenbacker, T.4
  • 25
    • 0014837346 scopus 로고
    • The microvascular pattern of the rotator cuff
    • Rathbun J., Macnab I. The microvascular pattern of the rotator cuff. J Bone Joint Surg Br 1970, 52:540-553.
    • (1970) J Bone Joint Surg Br , vol.52 , pp. 540-553
    • Rathbun, J.1    Macnab, I.2
  • 26
    • 3142712932 scopus 로고    scopus 로고
    • Electromyographic analysis of the rotator cuff and deltoid musculature during common shoulder external rotation exercises
    • Reinold M., Wilk K., Fleisig G. Electromyographic analysis of the rotator cuff and deltoid musculature during common shoulder external rotation exercises. J Ortho Sports Phys Ther 2004, 34:385-394. 10.2519/jospt.2004.0665.
    • (2004) J Ortho Sports Phys Ther , vol.34 , pp. 385-394
    • Reinold, M.1    Wilk, K.2    Fleisig, G.3
  • 27
    • 70350051187 scopus 로고    scopus 로고
    • The concurrent validity of a hand-held versus a stationary dynamometer in testing isometric shoulder strength
    • Roy J.-S., MacDermid J., Orton B., Tran T., Faber K., Drosdowech D., et al. The concurrent validity of a hand-held versus a stationary dynamometer in testing isometric shoulder strength. J Hand Ther 2009, 22:320-327. 10.1016/j.jht.2009.04.008.
    • (2009) J Hand Ther , vol.22 , pp. 320-327
    • Roy, J.-S.1    MacDermid, J.2    Orton, B.3    Tran, T.4    Faber, K.5    Drosdowech, D.6
  • 28
    • 0026465529 scopus 로고
    • Relationship between two measures of upper extremity strength: manual muscle test compared to hand-held myometry
    • Schwartz S., Cohen M., Herbison G., Shah A. Relationship between two measures of upper extremity strength: manual muscle test compared to hand-held myometry. Arch Phys Med Rehabil 1992, 73:1063-1068.
    • (1992) Arch Phys Med Rehabil , vol.73 , pp. 1063-1068
    • Schwartz, S.1    Cohen, M.2    Herbison, G.3    Shah, A.4
  • 29
    • 0023776022 scopus 로고
    • The validity and reliability of hand-held dynamometry in assessing isometric external rotator performance
    • Sullivan S., Chesley A., Hebert G., McFaull S., Scullion D. The validity and reliability of hand-held dynamometry in assessing isometric external rotator performance. Phys Ther 1988, 10:213-217.
    • (1988) Phys Ther , vol.10 , pp. 213-217
    • Sullivan, S.1    Chesley, A.2    Hebert, G.3    McFaull, S.4    Scullion, D.5
  • 30
    • 15744402317 scopus 로고    scopus 로고
    • Intrarater reliability of 1 repetition maximum estimation in determining shoulder internal rotation muscle strength performance
    • doi:10.1519/1533-4287(2005)19<163:IRORME>2.0.CO;2
    • Taylor J., Bandy W. Intrarater reliability of 1 repetition maximum estimation in determining shoulder internal rotation muscle strength performance. J Strength Cond Res 2005, 19:163-168. doi:10.1519/1533-4287(2005)19<163:IRORME>2.0.CO;2.
    • (2005) J Strength Cond Res , vol.19 , pp. 163-168
    • Taylor, J.1    Bandy, W.2
  • 31
    • 76349116518 scopus 로고    scopus 로고
    • Establishing normative data on scapulothoracic musculature using handheld dynamometry
    • Turner N., Ferguson K., Mobley B., Riemann B., Davies G. Establishing normative data on scapulothoracic musculature using handheld dynamometry. J Sport Rehabil 2009, 18:502-520.
    • (2009) J Sport Rehabil , vol.18 , pp. 502-520
    • Turner, N.1    Ferguson, K.2    Mobley, B.3    Riemann, B.4    Davies, G.5
  • 32
    • 0026023518 scopus 로고
    • Hand-held dynamometer: tester strength makes a difference
    • Wilkholm J., Bohannon R. Hand-held dynamometer: tester strength makes a difference. J Ortho Sports Phys Ther 1991, 13:191-197.
    • (1991) J Ortho Sports Phys Ther , vol.13 , pp. 191-197
    • Wilkholm, J.1    Bohannon, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.