메뉴 건너뛰기




Volumn 1, Issue , 2009, Pages 388-396

Selecting HVAC systems for typical UK office buildings

Author keywords

CAV; Energy performance; HVAC system; Office building; VAV

Indexed keywords

CAV; EARLY DESIGN STAGES; ENERGY CONSUMPTION; ENERGY PERFORMANCE; ENERGYPLUS; FRESH AIR; HVAC SYSTEM; INSULATION LEVEL; SET-POINT; SUPPLY AIR TEMPERATURE; VAV;

EID: 78149398086     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (10)

References (15)
  • 2
    • 0003513481 scopus 로고    scopus 로고
    • ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • ASHRAE (2007) Handbook-HVAC Applications (SI), American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
    • (2007) Handbook-HVAC Applications (SI)
  • 3
    • 0036027779 scopus 로고    scopus 로고
    • Inter-related effects of cooling strategies and building features on energy performance of office buildings
    • DOI 10.1016/S0378-7788(01)00081-0, PII S0378778801000810
    • Becker, R., and Paciuk, M. (2002) Inter-related effect of cooling strategies and building features on energy performance of office buildings. Energy and Buildings, 34, 25-31. (Pubitemid 32998167)
    • (2002) Energy and Buildings , vol.34 , Issue.1 , pp. 25-31
    • Becker, R.1    Paciuk, M.2
  • 4
    • 67349220779 scopus 로고    scopus 로고
    • Single-duct constant volume system optimization
    • Cho, Y.H., and Liu, M. (2009) Single-duct constant volume system optimization. Energy and Buildings, 41(8), 856-862.
    • (2009) Energy and Buildings , vol.41 , Issue.8 , pp. 856-862
    • Cho, Y.H.1    Liu, M.2
  • 5
    • 33947199868 scopus 로고    scopus 로고
    • CIBSE Chartered Institution of Building Services Engineers, London, UK
    • CIBSE (2006) Guide A: Environmental design, Chartered Institution of Building Services Engineers, London, UK.
    • (2006) Guide A: Environmental Design
  • 9
    • 38549098679 scopus 로고    scopus 로고
    • Analysis of annual heating and cooling energy requirements for office buildings in different climates in Turkey
    • DOI 10.1016/j.enbuild.2007.05.008, PII S0378778807001685
    • Eskin, N., Turkmen, H. (2008) Analysis of annual heating and cooling energy requirements for office buildings in different climates in Turkey. Energy and Buildings, 40, 763-773. (Pubitemid 351162998)
    • (2008) Energy and Buildings , vol.40 , Issue.5 , pp. 763-773
    • Eskin, N.1    Turkmen, H.2
  • 10
    • 48949115592 scopus 로고    scopus 로고
    • A new and innovative look at anti-insulation behaviour in building energy consumption
    • Masoso, O.T., Grobler, L.J. (2008) A new and innovative look at anti-insulation behaviour in building energy consumption. Energy and Buildings, 40, 1889-1894.
    • (2008) Energy and Buildings , vol.40 , pp. 1889-1894
    • Masoso, O.T.1    Grobler, L.J.2
  • 11
    • 78149297386 scopus 로고    scopus 로고
    • The Building Regulations Office of the Deputy Prime Minister, UK
    • The Building Regulations (2006) Approved document F: Ventilation, Office of the Deputy Prime Minister, UK.
    • (2006) Approved Document F: Ventilation
  • 12
    • 78149391976 scopus 로고
    • The Building Regulations Office of the Deputy Prime Minister, UK
    • The Building Regulations (1990) Approved document L: Conservation of fuel and power, Office of the Deputy Prime Minister, UK.
    • (1990) Approved Document L: Conservation of Fuel and Power
  • 13
    • 70449568226 scopus 로고    scopus 로고
    • The Building Regulations Office of the Deputy Prime Minister, UK
    • The Building Regulations (2006) Approved document L2: Conservation of fuel and power, Office of the Deputy Prime Minister, UK.
    • (2006) Approved Document L2: Conservation of Fuel and Power
  • 14
    • 33745494846 scopus 로고    scopus 로고
    • Multiple-zone ventilation and temperature control of a single-duct VAV system using model predictive strategy
    • DOI 10.1016/j.enbuild.2006.03.007, PII S0378778806000764
    • Yuan, S., Perez, R. (2006) Multiple-zone ventilation and temperature control of a single-duct VAV system using model predictive strategy. Energy and Buildings, 38, 1248-1261. (Pubitemid 43959866)
    • (2006) Energy and Buildings , vol.38 , Issue.10 , pp. 1248-1261
    • Yuan, S.1    Perez, R.2
  • 15
    • 33749402364 scopus 로고    scopus 로고
    • Energy aspects of HVAC system configurations - Problem definition and test cases
    • Zhang, Y., Wright, J. A., Hanby, V. I. (2006) Energy aspects of HVAC system configurations - problem definition and test cases, HVAC&R Research Special Issue, 12(3c), 871-888.
    • (2006) HVAC&R Research Special Issue , vol.12 , Issue.3 C , pp. 871-888
    • Zhang, Y.1    Wright, J.A.2    Hanby, V.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.