메뉴 건너뛰기




Volumn 55, Issue 20, 2010, Pages 6125-6139

Gap-filling methods for 3D PlanTIS data

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; IMAGE QUALITY; METABOLISM; METHODOLOGY; PLANT; PLANT PHYSIOLOGY; POSITRON EMISSION TOMOGRAPHY; THREE DIMENSIONAL IMAGING; TOMOGRAPHY;

EID: 78149339357     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/20/006     Document Type: Article
Times cited : (12)

References (15)
  • 1
    • 76149121533 scopus 로고    scopus 로고
    • Design and initial performance of PlanTIS, a high resolution positron emission tomograph for plants
    • Beer S et al 2010 Design and initial performance of PlanTIS, a high resolution positron emission tomograph for plants Phys. Med. Biol. 55 635-46
    • (2010) Phys. Med. Biol. , vol.55 , pp. 635-646
    • Beer, S.1
  • 3
    • 68849114351 scopus 로고    scopus 로고
    • Combined MRI-PET dissects dynamic changes in plant structures and functions
    • Jahnke S et al 2009 Combined MRI-PET dissects dynamic changes in plant structures and functions Plant J. 59 634-44
    • (2009) Plant J. , vol.59 , pp. 634-644
    • Jahnke, S.1
  • 4
    • 0023984278 scopus 로고
    • Constrained Fourier space method for compensation of missing data in emission computed tomography
    • Karp J S, Muehllehner G and Lewitt R M 1988 Constrained Fourier space method for compensation of missing data in emission computed tomography IEEE Trans. Med. Imaging 7 21-5
    • (1988) IEEE Trans. Med. Imaging , vol.7 , pp. 21-25
    • Karp, J.S.1    Muehllehner, G.2    Lewitt, R.M.3
  • 5
    • 33750411992 scopus 로고    scopus 로고
    • Kinetic analysis of carbon-11-labeled carbon dioxide for studying photosynthesis in a leaf using positron emitting tracer imaging system
    • Kawachi N, Sakamoto K, Ishii S, Fujimaki S, Suzui N, Ishioka N S and Matsuhashi S 2006 Kinetic analysis of carbon-11-labeled carbon dioxide for studying photosynthesis in a leaf using positron emitting tracer imaging system IEEE Trans. Nucl. Sci. 53 2991-7
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , pp. 2991-2997
    • Kawachi, N.1    Sakamoto, K.2    Ishii, S.3    Fujimaki, S.4    Suzui, N.5    Ishioka, N.S.6    Matsuhashi, S.7
  • 6
    • 76149140629 scopus 로고    scopus 로고
    • Exploring the transport of plant metabolites using positron emitting radiotracers
    • Kiser M R, Reid C D, Crowell A S, Phillips R P and Howell C R 2008 Exploring the transport of plant metabolites using positron emitting radiotracers HFSP J. 2 189-204
    • (2008) HFSP J. , vol.2 , pp. 189-204
    • Kiser, M.R.1    Reid, C.D.2    Crowell, A.S.3    Phillips, R.P.4    Howell, C.R.5
  • 7
    • 0142205244 scopus 로고    scopus 로고
    • An object-oriented library for 3D PET reconstruction using parallel computing
    • ed H Evers, G Glombitza, T Lehmann and H-P Meinzer Berlin: Springer
    • Labbé C et al 1999a An object-oriented library for 3D PET reconstruction using parallel computing Proc. Bildverarbeitung fuer die Medizin: Algorithmen-Systeme-Anwendungen, Informatik aktuell ed H Evers, G Glombitza, T Lehmann and H-P Meinzer (Berlin: Springer) pp 268-72
    • (1999) Proc. Bildverarbeitung Fuer Die Medizin: Algorithmen-Systeme-Anwendungen, Informatik Aktuell , pp. 268-272
    • Labbé, C.1
  • 8
    • 17644384217 scopus 로고    scopus 로고
    • An object-oriented library incorporating efficient projection/ backprojection operators for volume reconstruction in 3D PET
    • Egmond aan Zee, The Netherlands
    • Labbé C, Thielemans K, Zaidi H and Morel C 1999b An object-oriented library incorporating efficient projection/backprojection operators for volume reconstruction in 3D PET Proc. 3D99 Conf. (Egmond aan Zee, The Netherlands)
    • (1999) Proc. 3D99 Conf.
    • Labbé, C.1    Thielemans, K.2    Zaidi, H.3    Morel, C.4
  • 9
  • 11
    • 77951203057 scopus 로고    scopus 로고
    • Interpolation for the gap-filling of the HRRT PET sinograms by using the slices in the direction of the radial samples
    • Tuna U, Peltonen S and Ruotsalainen U 2009 Interpolation for the gap-filling of the HRRT PET sinograms by using the slices in the direction of the radial samples IEEE Nuclear Science Symp. Conf. Record pp 3273-9
    • (2009) IEEE Nuclear Science Symp. Conf. Record , pp. 3273-3279
    • Tuna, U.1    Peltonen, S.2    Ruotsalainen, U.3
  • 12
    • 77749264345 scopus 로고    scopus 로고
    • Gap-filling for the high-resolution PET sinograms with a dedicated DCT-domain filter
    • Tuna U, Peltonen S and Ruotsalainen U 2010 Gap-filling for the high-resolution PET sinograms with a dedicated DCT-domain filter IEEE Trans. Med. Imaging 29 830-39
    • (2010) IEEE Trans. Med. Imaging , vol.29 , pp. 830-839
    • Tuna, U.1    Peltonen, S.2    Ruotsalainen, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.