메뉴 건너뛰기




Volumn 37, Issue 12, 2010, Pages 884-891

Inter- and intra-rater reliability in fibroptic endoscopic evaluation of swallowing

Author keywords

Deglutition and deglutition disorders; Dysphagia; Endoscopy; Evaluation; Reliability

Indexed keywords

GLASS FIBER;

EID: 78149247851     PISSN: 0305182X     EISSN: 13652842     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2010.02116.x     Document Type: Article
Times cited : (43)

References (21)
  • 1
    • 0025651245 scopus 로고
    • Aging-related alterations in human upper esophageal sphincter function
    • Fulp SR, Dalton CB, Castell JA, Castell DO. Aging-related alterations in human upper esophageal sphincter function. Am J Gastroentel. 1990;85:1569-1572.
    • (1990) Am J Gastroentel , vol.85 , pp. 1569-1572
    • Fulp, S.R.1    Dalton, C.B.2    Castell, J.A.3    Castell, D.O.4
  • 3
    • 0025771581 scopus 로고
    • Altered swallowing function in elderly patients without dysphagia: radiologic findings in 56 cases
    • Ekberg O, Feinberg MJ. Altered swallowing function in elderly patients without dysphagia: radiologic findings in 56 cases. Am J Roentogenol. 1991;156:1181-1184.
    • (1991) Am J Roentogenol , vol.156 , pp. 1181-1184
    • Ekberg, O.1    Feinberg, M.J.2
  • 4
    • 0023768227 scopus 로고
    • Swallowing problems in the elderly
    • Sheth N, Diner W. Swallowing problems in the elderly. Dysphagia. 1988;3:209-215.
    • (1988) Dysphagia , vol.3 , pp. 209-215
    • Sheth, N.1    Diner, W.2
  • 5
    • 0023815587 scopus 로고
    • Fiberoptic endoscopic examination of swallowing safety: a new procedure
    • Langmore SE, Schatz K, Olsen N. Fiberoptic endoscopic examination of swallowing safety: a new procedure. Dysphagia. 1988;2:216-219.
    • (1988) Dysphagia , vol.2 , pp. 216-219
    • Langmore, S.E.1    Schatz, K.2    Olsen, N.3
  • 6
    • 0025917486 scopus 로고
    • Endoscopic and videofluoroscopic evaluations of swallowing and aspiration
    • Langmore SE, Schatz K, Olson N. Endoscopic and videofluoroscopic evaluations of swallowing and aspiration. Ann Otol Rhinol Laryngol. 1991;100:678-681.
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 678-681
    • Langmore, S.E.1    Schatz, K.2    Olson, N.3
  • 7
    • 0031003357 scopus 로고    scopus 로고
    • Evaluation of swallowing safety with fiberoptic endoscopic: comparison with videofluoroscopic technique
    • Wu CH, Hsiao TY, Chen JC, Chang YC, Lee SY. Evaluation of swallowing safety with fiberoptic endoscopic: comparison with videofluoroscopic technique. Laryngoscope. 1997;107:396-401.
    • (1997) Laryngoscope , vol.107 , pp. 396-401
    • Wu, C.H.1    Hsiao, T.Y.2    Chen, J.C.3    Chang, Y.C.4    Lee, S.Y.5
  • 9
    • 0344157483 scopus 로고    scopus 로고
    • Role of videoendoscopy in assessment of pharyngeal function in oropharyngeal dysphagia: comparison with videofluoroscopy and manometry
    • Perie S, Laccourreye L, Flahault A, Hazebroucq V, Chaussade S, St Guily JL. Role of videoendoscopy in assessment of pharyngeal function in oropharyngeal dysphagia: comparison with videofluoroscopy and manometry. Laryngoscope. 1998;108:1712-1716.
    • (1998) Laryngoscope , vol.108 , pp. 1712-1716
    • Perie, S.1    Laccourreye, L.2    Flahault, A.3    Hazebroucq, V.4    Chaussade, S.5    St Guily, J.L.6
  • 10
    • 78149236569 scopus 로고    scopus 로고
    • Videoendoscopy in a visiting dental treatment; the actual swallowing conditions of dysphagic patients in home care
    • Hattori F, Tohara H, Nakane A, Ouchi Y, Uematsu H. Videoendoscopy in a visiting dental treatment; the actual swallowing conditions of dysphagic patients in home care. Dysphagia. 2007;22:316.
    • (2007) Dysphagia , vol.22 , pp. 316
    • Hattori, F.1    Tohara, H.2    Nakane, A.3    Ouchi, Y.4    Uematsu, H.5
  • 12
    • 0036731509 scopus 로고    scopus 로고
    • Interjudge and intrajudge reliabilities in fiberoptic endoscopic evaluation of swallowing (fees) using the penetration-aspiration scale: a replication study
    • Colodny N. Interjudge and intrajudge reliabilities in fiberoptic endoscopic evaluation of swallowing (fees) using the penetration-aspiration scale: a replication study. Dysphagia. 2002;17:308-315.
    • (2002) Dysphagia , vol.17 , pp. 308-315
    • Colodny, N.1
  • 13
    • 34848829544 scopus 로고    scopus 로고
    • Assessing penetration and aspiration: how do videofluoroscopy and fiberoptic endoscopic evaluation of swallowing compare?
    • Kelly AM, Drinnan MJ, Leslie P. Assessing penetration and aspiration: how do videofluoroscopy and fiberoptic endoscopic evaluation of swallowing compare? Laryngoscope. 2007;117:1723-1727.
    • (2007) Laryngoscope , vol.117 , pp. 1723-1727
    • Kelly, A.M.1    Drinnan, M.J.2    Leslie, P.3
  • 14
    • 33749429418 scopus 로고    scopus 로고
    • Fiberoptic evaluation of swallowing and videofluoroscopiy: does examination type influence perception of pharyngeal residue severity?
    • Kelly AM, Leslie P, Beale T, Payten C, Drinnan MJ. Fiberoptic evaluation of swallowing and videofluoroscopiy: does examination type influence perception of pharyngeal residue severity? Clin Otolaryngol. 2006;31:425-432.
    • (2006) Clin Otolaryngol , vol.31 , pp. 425-432
    • Kelly, A.M.1    Leslie, P.2    Beale, T.3    Payten, C.4    Drinnan, M.J.5
  • 15
    • 0023720470 scopus 로고
    • Interobserver variability in cineradiographic assessment of pharyngeal function during swallow
    • Ekberg O, Nylander G, Fork FT, Sjöberg S, Birch-Iensen M, Hillarp B. Interobserver variability in cineradiographic assessment of pharyngeal function during swallow. Dysphagia. 1988;3:46-48.
    • (1988) Dysphagia , vol.3 , pp. 46-48
    • Ekberg, O.1    Nylander, G.2    Fork, F.T.3    Sjöberg, S.4    Birch-Iensen, M.5    Hillarp, B.6
  • 16
    • 0029996893 scopus 로고    scopus 로고
    • Interjudge agreement in videofluoroscopic studies of swallowing
    • Wilcox F, Liss JM, Siegel GM. Interjudge agreement in videofluoroscopic studies of swallowing. J Speech Hear Res. 1996;39:144-152.
    • (1996) J Speech Hear Res , vol.39 , pp. 144-152
    • Wilcox, F.1    Liss, J.M.2    Siegel, G.M.3
  • 17
    • 0031805204 scopus 로고    scopus 로고
    • Intra- and interrater variation in the evaluation of videofluorographic swallowing studies
    • Kuhlemeier KV, Yates P, Palmer JB. Intra- and interrater variation in the evaluation of videofluorographic swallowing studies. Dysphagia. 1998;13:142-147.
    • (1998) Dysphagia , vol.13 , pp. 142-147
    • Kuhlemeier, K.V.1    Yates, P.2    Palmer, J.B.3
  • 20
    • 0031724172 scopus 로고    scopus 로고
    • A study of interrater reliability when using videofluoroscopy as an assessment of swallowing
    • Scott A, Perry A, Bench J. A study of interrater reliability when using videofluoroscopy as an assessment of swallowing. Dysphagia. 1998;13:223-227.
    • (1998) Dysphagia , vol.13 , pp. 223-227
    • Scott, A.1    Perry, A.2    Bench, J.3
  • 21
    • 78149252552 scopus 로고    scopus 로고
    • Inter- and Intra-rater reliability in videofluoroscopic swallowing study
    • (Japanese).
    • Tohara H, Chiba Y, Nakane A, Goto S, Ouchi Y, Teranaka S et al. Inter- and Intra-rater reliability in videofluoroscopic swallowing study. Jpn J Dysphagia Rehab. 2005;9:139-147. (Japanese).
    • (2005) Jpn J Dysphagia Rehab , vol.9 , pp. 139-147
    • Tohara, H.1    Chiba, Y.2    Nakane, A.3    Goto, S.4    Ouchi, Y.5    Teranaka, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.