Can heterogeneity in ventilation be good?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT RESPIRATORY DISTRESS SYNDROME; AERATION; ARTIFICIAL VENTILATION; COMPUTER ASSISTED IMPEDANCE TOMOGRAPHY; HUMAN; INTENSIVE CARE; LUNG; LUNG ALVEOLUS; LUNG COLLAPSE; LUNG VENTILATION; LUNG VOLUME; NOTE; OXYGEN SUPPLY; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; VENTILATOR INDUCED LUNG INJURY; CRITICAL ILLNESS; DECISION MAKING; IMPEDANCE; LUNG INJURY; METHODOLOGY;

EID: 78149236338     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc8901     Document Type: Note
Times cited : (12)

References (12)
  • 1
    • 77649305606 scopus 로고    scopus 로고
    • PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography
    • 10.1186/cc8860, 20113520, 2875520
    • Zhao Z, Steinmann D, Frerichs I, Guttmann J, Möller K. PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography. Crit Care 2010, 14:R8. 10.1186/cc8860, 20113520, 2875520.
    • (2010) Crit Care , vol.14
    • Zhao, Z.1    Steinmann, D.2    Frerichs, I.3    Guttmann, J.4    Möller, K.5
  • 3
    • 33845959980 scopus 로고    scopus 로고
    • Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study
    • 10.1097/01.CCM.0000251131.40301.E2, 17110872
    • Suarez-Sipmann F, Böhm SH, Tusman G, Pesch T, Thamm O, Reissmann H, Reske A, Magnusson A, Hedenstierna G. Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study. Crit Care Med 2007, 35:214-221. 10.1097/01.CCM.0000251131.40301.E2, 17110872.
    • (2007) Crit Care Med , vol.35 , pp. 214-221
    • Suarez-Sipmann, F.1    Böhm, S.H.2    Tusman, G.3    Pesch, T.4    Thamm, O.5    Reissmann, H.6    Reske, A.7    Magnusson, A.8    Hedenstierna, G.9
  • 4
    • 0022578276 scopus 로고
    • Correlation of gas exchange impairment to development of atelectasis during anaesthesia and muscle paralysis
    • 10.1111/j.1399-6576.1986.tb02393.x, 3085429
    • Hedenstierna G, Tokics L, Strandberg A, Lundquist H, Brismar B. Correlation of gas exchange impairment to development of atelectasis during anaesthesia and muscle paralysis. Acta Anaesthesiol Scand 1986, 30:183-191. 10.1111/j.1399-6576.1986.tb02393.x, 3085429.
    • (1986) Acta Anaesthesiol Scand , vol.30 , pp. 183-191
    • Hedenstierna, G.1    Tokics, L.2    Strandberg, A.3    Lundquist, H.4    Brismar, B.5
  • 6
    • 67349183203 scopus 로고    scopus 로고
    • Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography
    • 10.1007/s00134-009-1447-y, 19255741
    • Costa EL, Borges JB, Melo A, Suarez-Sipmann F, Toufen C, Bohm SH, Amato MB. Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography. Intensive Care Med 2009, 35:1132-1137. 10.1007/s00134-009-1447-y, 19255741.
    • (2009) Intensive Care Med , vol.35 , pp. 1132-1137
    • Costa, E.L.1    Borges, J.B.2    Melo, A.3    Suarez-Sipmann, F.4    Toufen, C.5    Bohm, S.H.6    Amato, M.B.7
  • 7
    • 43049127187 scopus 로고    scopus 로고
    • Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography
    • 10.1007/s00134-007-0786-9, 17653529
    • Meier T, Luepschen H, Karsten J, Leibecke T, Grossherr M, Gehring H, Leonhardt S. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography. Intensive Care Med 2008, 34:543-550. 10.1007/s00134-007-0786-9, 17653529.
    • (2008) Intensive Care Med , vol.34 , pp. 543-550
    • Meier, T.1    Luepschen, H.2    Karsten, J.3    Leibecke, T.4    Grossherr, M.5    Gehring, H.6    Leonhardt, S.7
  • 9
    • 0016681272 scopus 로고
    • Effect of shape and size of lung and chest wall on stresses in the lung
    • Vawter DL, Matthews FL, West JB. Effect of shape and size of lung and chest wall on stresses in the lung. J Appl Physiol 1975, 39:9-17.
    • (1975) J Appl Physiol , vol.39 , pp. 9-17
    • Vawter, D.L.1    Matthews, F.L.2    West, J.B.3
  • 10
    • 0015304924 scopus 로고
    • Stresses, strains, and surface pressures in the lung caused by its weight
    • West JB, Matthews FL. Stresses, strains, and surface pressures in the lung caused by its weight. J Appl Physiol 1972, 32:332-345.
    • (1972) J Appl Physiol , vol.32 , pp. 332-345
    • West, J.B.1    Matthews, F.L.2
  • 11
    • 0035156078 scopus 로고    scopus 로고
    • Best compliance during a decremental, but not incremental, positive end-expiratory pressure trial is related to open-lung positive end-expiratory pressure: a mathematical model of acute respiratory distress syndrome lungs
    • Hickling KG. Best compliance during a decremental, but not incremental, positive end-expiratory pressure trial is related to open-lung positive end-expiratory pressure: a mathematical model of acute respiratory distress syndrome lungs. Am J Respir Crit Care Med 2001, 163:69-78.
    • (2001) Am J Respir Crit Care Med , vol.163 , pp. 69-78
    • Hickling, K.G.1
  • 12
    • 73949116537 scopus 로고    scopus 로고
    • Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution
    • 10.1007/s00134-009-1589-y, 19652949
    • Zhao Z, Möller K, Steinmann D, Frerichs I, Guttmann J. Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution. Intensive Care Med 2009, 35:1900-1906. 10.1007/s00134-009-1589-y, 19652949.
    • (2009) Intensive Care Med , vol.35 , pp. 1900-1906
    • Zhao, Z.1    Möller, K.2    Steinmann, D.3    Frerichs, I.4    Guttmann, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.